|
|
||||||||||
|
J Am Coll Cardiol, 1995; 26:870-878 © 1995 by the American College of Cardiology Foundation |
Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, Tennessee 37232-2675, USA.
OBJECTIVES. This study sought to develop a dual-isotope single-acquisition single-photon emission computed tomographic (SPECT) protocol using a multihead SPECT camera equipped with an ultra-high energy collimator to evaluate rest metabolism/stress perfusion simultaneously with fluorine-18 (F-18) deoxyglucose/technetium-99m (Tc-99m) 2-hexakis-2-methoxy-2-methylpropyl isonitrile (MIBI). BACKGROUND. The most accurate and logistic method of identifying injured but viable myocardium remains a diagnostic challenge. METHODS. Sixty-five patients were given 25 to 50 g of glucose and, after approximately 60 min, an injection of 370 MBq (10 mCi) of F-18 fluorodeoxyglucose. After a 35-min distribution phase, patients underwent exercise or pharmacologic stress followed by administration of 925 MBq (25 mCi) of Tc-99m MIBI. Five patients underwent F-18 fluorodeoxyglucose position emission tomography before dual-isotope SPECT. RESULTS. With a window of 20% for both photopeaks and a technetium-99m/fluorine-18 concentration of 3.2:1, the "spillover" from fluorine-18 into the technetium-99m window is < 6% of the total counts in the window in patients with a normal distribution of both radiopharmaceuticals. Phantom images clearly demonstrated cardiac defects measuring 2 x 1 and 2 x 0.5 cm. There was no significant difference in the images of the five patients who underwent both positron emission tomography and SPECT. Fifty-seven patients (mean [+/- SD] age 55 +/- 15 years, range 25 to 83; 38 men, 19 women) had satisfactory images and were included in the study. Twenty-one patients had normal study results; 15 had mismatched defects; 14 had matched defects; and 7 had both matched and mismatched defects. Twenty-three patients (mean age 54 +/- 6 years, range 30 to 83; 14 men, 9 women) underwent coronary angiography within 3 months of dual-isotope SPECT. There were seven normal studies, eight with mismatched defects, one with a matched defect and seven with matched and mismatched defects. When stenosis > 70% was used as the criterion for a diagnosis of coronary artery disease, dual-isotope SPECT had a sensitivity of 100%, specificity of 88%, positive predictive value of 93%, negative predictive value of 100% and an accuracy of 96%. CONCLUSIONS. Dual-isotope SPECT may provide an alternative, accurate, cost-effective method to nitrogen-13 ammonia/F-18 fluorodeoxyglucose positron emission tomography or thallium-201 reinjection for identifying injured or dysfunctional but viable myocardium.
This article has been cited by other articles:
![]() |
A. F.L. Schinkel, J. J. Bax, R. Valkema, A. Elhendy, R. T. van Domburg, E. C. Vourvouri, M. A. Bountioukos, E. P. Krenning, J. R.T.C. Roelandt, and D. Poldermans Effect of Diabetes Mellitus on Myocardial 18F-FDG SPECT Using Acipimox for the Assessment of Myocardial Viability J. Nucl. Med., June 1, 2003; 44(6): 877 - 883. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. L.R. Kam, R. Valkema, D. Poldermans, J. J. Bax, A. E.M. Reijs, R. Rambaldi, E. Boersma, T. Rietveld, J. R.T.C. Roelandt, and E. P. Krenning Feasibility and Image Quality of Dual-Isotope SPECT Using 18F-FDG and 99mTc-Tetrofosmin After Acipimox Administration J. Nucl. Med., February 1, 2003; 44(2): 140 - 145. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. A. Pagnanelli, M. W. Hanson, T. Turkington, R. E. Coleman, and S. Borges-Neto Gated 99mTc-Tetrofosmin and 18F-FDG Studies: A Comparison of Single-Acquisition and Separate-Acquisition Protocols J. Nucl. Med. Technol., December 1, 2002; 30(4): 175 - 178. [Abstract] [Full Text] [PDF] |
||||
![]() |
A F L Schinkel, J J Bax, F B Sozzi, E Boersma, R Valkema, A Elhendy, J R T C Roelandt, and D Poldermans Prevalence of myocardial viability assessed by single photon emission computed tomography in patients with chronic ischaemic left ventricular dysfunction Heart, August 1, 2002; 88(2): 125 - 130. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Matsunari, T. Yoneyama, S. Kanayama, M. Matsudaira, K. Nakajima, J. Taki, S. G. Nekolla, N. Tonami, and K. Hisada Phantom Studies for Estimation of Defect Size on Cardiac 18F SPECT and PET: Implications for Myocardial Viability Assessment J. Nucl. Med., October 1, 2001; 42(10): 1579 - 1585. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. V.R. Di Bella, D. J. Kadrmas, and P. E. Christian Feasibility of Dual-Isotope Coincidence/Single-Photon Imaging of the Myocardium J. Nucl. Med., June 1, 2001; 42(6): 944 - 950. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.-M. J. Siebelink, P. K. Blanksma, H. J. G. M. Crijns, J. J. Bax, A. J. van Boven, T. Kingma, D. A. Piers, J. Pruim, P. L. Jager, W. Vaalburg, et al. No difference in cardiac event-free survival between positron emission tomography-guided and single-photon emission computed tomography-guided patient management: A prospective, randomized comparison of patients with suspicion of jeopardized myocardium J. Am. Coll. Cardiol., January 1, 2001; 37(1): 81 - 88. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. E. Udelson Steps Forward in the Assessment of Myocardial Viability in Left Ventricular Dysfunction Circulation, March 10, 1998; 97(9): 833 - 838. [Full Text] [PDF] |
||||
![]() |
G. Srinivasan, A. N. Kitsiou, S. L. Bacharach, M. L. Bartlett, C. Miller-Davis, and V. Dilsizian [18F]Fluorodeoxyglucose Single Photon Emission Computed Tomography : Can It Replace PET and Thallium SPECT for the Assessment of Myocardial Viability? Circulation, March 10, 1998; 97(9): 843 - 850. [Abstract] [Full Text] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |