J Am Coll Cardiol, 1995; 26:446-451 © 1995 by the American College of Cardiology Foundation |
Service de Chirurgie Cardiaque, Centre Hospitalier et Universitaire Henri Mondor, Creteil, France.
OBJECTIVES. The aim of the present study was to evaluate the coronary vasomotor response to the cold-pressor test within 3 months after heart transplantation. BACKGROUND. Normal epicardial coronary arteries dilate in response to sympathetic stimulation evoked by the cold-pressor test. In transplant recipients, abnormal coronary vasomotion has been described shortly after operation. METHODS. Fourteen heart transplant recipients were compared 52 +/- 15 days (mean +/- SD) after operation with 10 control subjects. All had angiographically normal epicardial coronary arteries. Coronary blood flow velocity was measured with a Doppler catheter placed in the proximal left anterior descending coronary artery. Four segments in each patient were analyzed by quantitative coronary angiography to assess the diameter changes during the cold-pressor test and after intracoronary injection of isosorbide dinitrate. RESULTS. Coronary flow velocity increased similarly during the cold-pressor test in control subjects and in transplant recipients, from 7.5 +/- 2.3 to 11.0 +/- 3.9 cm/s and from 10.3 +/- 3.2 to 13.7 +/- 4.8 cm/s (both p < 0.01). In control subjects, 39 of 40 segments analyzed dilated during the cold-pressor test. In transplant recipients, 48 of 56 segments analyzed did not change or constricted. The mean epicardial coronary diameter increased significantly during the cold-pressor test in control subjects (+13 +/- 6%, p < 0.001), whereas it did not change significantly in transplant recipients (-2 +/- 9%, p = NS). In transplant recipients, isosorbide dinitrate elicited coronary vasodilation similar to that in control subjects. CONCLUSIONS. These data indicate that in human transplanted denervated hearts, coronary vasodilation in response to sympathetic stimulation by cold exposure is impaired shortly after operation.
This article has been cited by other articles:
![]() |
G. Vassalli, A. Gallino, M. Weis, W. von Scheidt, L. Kappenberger, L.K. von Segesser, J.-J. Goy, and on behalf of the Working Group Microcirculation of Alloimmunity and nonimmunologic risk factors in cardiac allograft vasculopathy Eur. Heart J., July 1, 2003; 24(13): 1180 - 1188. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Weis and J. P. Cooke Cardiac Allograft Vasculopathy and Dysregulation of the NO Synthase Pathway Arterioscler. Thromb. Vasc. Biol., April 1, 2003; 23(4): 567 - 575. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Chemla, E. Aptecar, J.-L. Hebert, C. Coirault, D. Loisance, Y. Lecarpentier, and A. Nitenberg Short-term variability of pulse pressure and systolic and diastolic time in heart transplant recipients Am J Physiol Heart Circ Physiol, July 1, 2000; 279(1): H122 - H129. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. E. Reis, V. Bhoopalam, K. A. Zell, P. J. Counihan, A. J. C. Smith, S. Pham, and S. Murali Conjugated Estrogens Acutely Abolish Abnormal Cold-Induced Coronary Vasoconstriction in Male Cardiac Allografts Circulation, January 13, 1998; 97(1): 23 - 25. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. F. Kofoed, J. Czernin, J. Johnson, J. Kobashigawa, M. E. Phelps, H. Laks, and H. R. Schelbert Effects of Cardiac Allograft Vasculopathy on Myocardial Blood Flow, Vasodilatory Capacity, and Coronary Vasomotion Circulation, February 4, 1997; 95(3): 600 - 606. [Abstract] [Full Text] |
||||
![]() |
E. Aptecar, P. Dupouy, C. Benvenuti, J.-P. Mazzucotelli, E. Teiger, H. Geschwind, A. Castaigne, D. Loisance, and J.-L. Dubois-Rande Sympathetic Stimulation Overrides Flow-Mediated Endothelium-Dependent Epicardial Coronary Vasodilation in Transplant Patients Circulation, November 15, 1996; 94(10): 2542 - 2550. [Abstract] [Full Text] |
||||