JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1995; 26:446-451
© 1995 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Benvenuti, C
Right arrow Articles by Nitenberg, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Benvenuti, C
Right arrow Articles by Nitenberg, A

Coronary artery response to cold-pressor test is impaired early after operation in heart transplant recipients

C Benvenuti, E Aptecar, JP Mazzucotelli, P Jouannot, D Loisance, and A Nitenberg

Service de Chirurgie Cardiaque, Centre Hospitalier et Universitaire Henri Mondor, Creteil, France.

OBJECTIVES. The aim of the present study was to evaluate the coronary vasomotor response to the cold-pressor test within 3 months after heart transplantation. BACKGROUND. Normal epicardial coronary arteries dilate in response to sympathetic stimulation evoked by the cold-pressor test. In transplant recipients, abnormal coronary vasomotion has been described shortly after operation. METHODS. Fourteen heart transplant recipients were compared 52 +/- 15 days (mean +/- SD) after operation with 10 control subjects. All had angiographically normal epicardial coronary arteries. Coronary blood flow velocity was measured with a Doppler catheter placed in the proximal left anterior descending coronary artery. Four segments in each patient were analyzed by quantitative coronary angiography to assess the diameter changes during the cold-pressor test and after intracoronary injection of isosorbide dinitrate. RESULTS. Coronary flow velocity increased similarly during the cold-pressor test in control subjects and in transplant recipients, from 7.5 +/- 2.3 to 11.0 +/- 3.9 cm/s and from 10.3 +/- 3.2 to 13.7 +/- 4.8 cm/s (both p < 0.01). In control subjects, 39 of 40 segments analyzed dilated during the cold-pressor test. In transplant recipients, 48 of 56 segments analyzed did not change or constricted. The mean epicardial coronary diameter increased significantly during the cold-pressor test in control subjects (+13 +/- 6%, p < 0.001), whereas it did not change significantly in transplant recipients (-2 +/- 9%, p = NS). In transplant recipients, isosorbide dinitrate elicited coronary vasodilation similar to that in control subjects. CONCLUSIONS. These data indicate that in human transplanted denervated hearts, coronary vasodilation in response to sympathetic stimulation by cold exposure is impaired shortly after operation.


This article has been cited by other articles:


Home page
Eur Heart JHome page
G. Vassalli, A. Gallino, M. Weis, W. von Scheidt, L. Kappenberger, L.K. von Segesser, J.-J. Goy, and on behalf of the Working Group Microcirculation of
Alloimmunity and nonimmunologic risk factors in cardiac allograft vasculopathy
Eur. Heart J., July 1, 2003; 24(13): 1180 - 1188.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
M. Weis and J. P. Cooke
Cardiac Allograft Vasculopathy and Dysregulation of the NO Synthase Pathway
Arterioscler. Thromb. Vasc. Biol., April 1, 2003; 23(4): 567 - 575.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
D. Chemla, E. Aptecar, J.-L. Hebert, C. Coirault, D. Loisance, Y. Lecarpentier, and A. Nitenberg
Short-term variability of pulse pressure and systolic and diastolic time in heart transplant recipients
Am J Physiol Heart Circ Physiol, July 1, 2000; 279(1): H122 - H129.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. E. Reis, V. Bhoopalam, K. A. Zell, P. J. Counihan, A. J. C. Smith, S. Pham, and S. Murali
Conjugated Estrogens Acutely Abolish Abnormal Cold-Induced Coronary Vasoconstriction in Male Cardiac Allografts
Circulation, January 13, 1998; 97(1): 23 - 25.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
K. F. Kofoed, J. Czernin, J. Johnson, J. Kobashigawa, M. E. Phelps, H. Laks, and H. R. Schelbert
Effects of Cardiac Allograft Vasculopathy on Myocardial Blood Flow, Vasodilatory Capacity, and Coronary Vasomotion
Circulation, February 4, 1997; 95(3): 600 - 606.
[Abstract] [Full Text]


Home page
CirculationHome page
E. Aptecar, P. Dupouy, C. Benvenuti, J.-P. Mazzucotelli, E. Teiger, H. Geschwind, A. Castaigne, D. Loisance, and J.-L. Dubois-Rande
Sympathetic Stimulation Overrides Flow-Mediated Endothelium-Dependent Epicardial Coronary Vasodilation in Transplant Patients
Circulation, November 15, 1996; 94(10): 2542 - 2550.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1995 by the American College of Cardiology Foundation.