Incidence of aneurysm formation after Dacron patch aortoplasty repair for coarctation of the aorta: long-term results and assessment utilizing magnetic resonance angiography with three-dimensional surface rendering
WJ Parks,
TD Ngo,
WH Plauth Jr,
ER Bank,
SK Sheppard,
RI Pettigrew,
and
WH Williams
Children's Heart Center at Emory University, Atlanta, Georgia 30322, USA.
OBJECTIVES. Magnetic resonance angiography with three-dimensional surface rendering was performed to determine its value in assessing anatomic detail in patients with suspected aortic aneurysms. BACKGROUND. Dacron patch aortoplasty repair of coarctation of the aorta carries an inherent risk of aneurysm development. Sudden death from aortic rupture prompted discontinuing this operation and evaluating 39 patients (16 girls; mean age 6.3 years, range 10 days to 14.5 years) undergoing repair between January 1976 and October 1987. The aorta ruptured in 10 patients; 6 died at a mean interval of 8.1 years (range 0.75 to 12.4) after repair. All 33 survivors were interviewed and examined. METHODS. Conventional magnetic resonance imaging was performed in 26 patients, magnetic resonance angiography in 18. Angiographic slices were used to reconstruct three-dimensional images. No catheterization or contrast angiography was performed. Surgical intervention was based on clinical findings and magnetic resonance images. RESULTS. Twenty patients (11 girls) developed aneurysms, of which nine were detected in patients studied by magnetic resonance. Ruptures occurred in eight female patients, three of whom were pregnant. Surface renderings accurately defined aortic anatomy or aneurysms in all patients. On follow-up, no aneurysms have been detected in patients with negative magnetic resonance study results. Precise anatomic correlation with operative findings was reported. CONCLUSIONS. Magnetic resonance angiography with three-dimensional surface rendering provides noninvasive, radiation-free and contrast agent-free high resolution images of the thoracic aorta. These images can be reviewed and have three-dimensional form and perspective. These techniques were preferred over invasive angiography by surgeons and clinicians as definitive, risk-free procedures before surgical intervention.
This article has been cited by other articles:

|
 |

|
 |
 
T. J. Forbes, D. W. Kim, W. Du, D. R. Turner, R. Holzer, Z. Amin, Z. Hijazi, A. Ghasemi, J. J. Rome, D. Nykanen, et al.
Comparison of Surgical, Stent, and Balloon Angioplasty Treatment of Native Coarctation of the Aorta: An Observational Study by the CCISC (Congenital Cardiovascular Interventional Study Consortium)
J. Am. Coll. Cardiol.,
December 13, 2011;
58(25):
2664 - 2674.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
E. Troost, M. Gewillig, W. Daenen, B. Meyns, J. Bogaert, K. Van Deyk, and W. Budts
Behaviour of polyester grafts in adult patients with repaired coarctation of the aorta
Eur. Heart J.,
May 1, 2009;
30(9):
1136 - 1141.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. M. Gaca, J. J. Jaggers, L. T. Dudley, and G. S. Bisset III
Repair of Congenital Heart Disease: A Primer--Part 2
Radiology,
July 1, 2008;
248(1):
44 - 60.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Y. Inoue, T. Ueda, S. Taguchi, I. Kashima, K. Koizumi, and T. Kimura
Nonaneurysmal rupture 30 years after patch aortoplasty for coarctation
J. Thorac. Cardiovasc. Surg.,
December 1, 2006;
132(6):
1480 - 1481.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Tzifa, P. Ewert, G. Brzezinska-Rajszys, B. Peters, M. Zubrzycka, E. Rosenthal, F. Berger, and S. A. Qureshi
Covered Cheatham-Platinum Stents for Aortic Coarctation: Early and Intermediate-Term Results
J. Am. Coll. Cardiol.,
April 4, 2006;
47(7):
1457 - 1463.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. M. Oliver, P. Gallego, A. Gonzalez, A. Aroca, M. Bret, and J. M. Mesa
Risk factors for aortic complications in adults with coarctation of the aorta
J. Am. Coll. Cardiol.,
October 19, 2004;
44(8):
1641 - 1647.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Ince, M. Petzsch, T. Rehders, S. Kische, T. Korber, F. Weber, and C. A. Nienaber
Percutaneous Endovascular Repair of Aneurysm After Previous Coarctation Surgery
Circulation,
December 16, 2003;
108(24):
2967 - 2970.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. J. Walhout, J. C. Lekkerkerker, G. H. Oron, F. J. Hitchcock, E. J. Meijboom, and G. B.W.E. Bennink
Comparison of polytetrafluoroethylene patch aortoplasty and end-to-end anastomosis for coarctation of the aorta
J. Thorac. Cardiovasc. Surg.,
August 1, 2003;
126(2):
521 - 528.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. E. Bell, P. R. Taylor, M. Aukett, C. P. Young, D. R. Anderson, and J. F. Reidy
Endoluminal repair of aneurysms associated with coarctation
Ann. Thorac. Surg.,
February 1, 2003;
75(2):
530 - 533.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Roth, P. Lemke, M. Schonburg, W.-P. Klovekorn, and E. P. Bauer
Aneurysm formation after patch aortoplasty repair (vossschulte): reoperation in adults with and without hypothermic circulatory arrest
Ann. Thorac. Surg.,
December 1, 2002;
74(6):
2047 - 2050.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Y. von Kodolitsch, M. A. Aydin, D. H. Koschyk, R. Loose, I. Schalwat, M. Karck, J. Cremer, A. Haverich, J.u. Berger, T. Meinertz, et al.
Predictors of aneurysmal formation after surgical correction of aortic coarctation
J. Am. Coll. Cardiol.,
February 20, 2002;
39(4):
617 - 624.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. P. Nieminen, E. V. Jokinen, and H. I. Sairanen
Late Results of Pediatric Cardiac Surgery in Finland: A Population-Based Study With 96% Follow-Up
Circulation,
July 31, 2001;
104(5):
570 - 575.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Bogaert, S. Dymarkowski, W. Budts, M. Gewillig, and W. Daenen
Graft dilation after redo surgery for aneurysm formation following patch angioplasty for aortic coarctation
Eur J Cardiothorac Surg,
March 1, 2001;
19(3):
274 - 278.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B. H. Smaill, D. C. McGiffin, I. J. LeGrice, A. A. Young, P. J. Hunter, and A. J. Galbraith
The effect of synthetic patch repair of coarctation on regional deformation of the aortic wall
J. Thorac. Cardiovasc. Surg.,
December 1, 2000;
120(6):
1053 - 1063.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A G Magee, G Brzezinska-Rajszys, S A Qureshi, E Rosenthal, M Zubrzycka, J Ksiazyk, and M Tynan
Stent implantation for aortic coarctation and recoarctation
Heart,
November 1, 1999;
82(5):
600 - 606.
[Abstract]
[Full Text]
|
 |
|
|