Quantitative assessment of myocardial ultrasound tissue characterization through receiver operating characteristic analysis of Bayesian classifiers
RF Wagner,
KA Wear,
JE Perez,
JB McGill,
KB Schechtman,
and
JG Miller
Office of Science and Technology, U.S. Food and Drug Administration, Rockville, Maryland 20857, USA.
OBJECTIVES. This work proposes a self-consistent assessment methodology for quantitative evaluation of any combination of diagnostic features, with the immediate goal of quantitatively assessing the discriminating power in diabetic patients of features derived from ultrasound backscatter from myocardium. BACKGROUND. Four features from analysis of left ventricular myocardial ultrasound backscatter have previously been shown to be sensitive to potentially cardiomyopathic changes in patients with insulin-dependent diabetes mellitus who have no overt heart disease. The measured features were significantly different between such patients and normal control subjects, as well as among groups of such patients with and without systemic complications of the disease. The quantitative discriminating potential of the features was not assessed. METHODS. Multivariate classifier functions were constructed and analyzed by using the methodology of the receiver operating characteristic curve, which allows quantitative assessment of the discriminating power of these features, alone or in combination. The area under the receiver operating characteristic curve--the true positive rate averaged over all false positive rates--was used as a summary measure of performance. RESULTS. In distinguishing patients with insulin-dependent diabetes mellitus from normal control subjects, the most discriminating combination of ultrasound features for the detection of such changes in these patients yielded receiver operating characteristic curves with area measures of approximately 0.80; for such patients with retinopathy the measure increased to 0.90. This performance is comparable to that of many commonly used diagnostic tests. CONCLUSIONS. A self-consistent set of evaluation methodologies has quantitatively demonstrated the sensitivity of four ultrasound backscatter features to otherwise latent changes in myocardial structure that accompany the evolution of insulin-dependent diabetes mellitus. The results are remarkable in themselves and suggest the potential of the features for the general field of cardiac ultrasound tissue characterization.
This article has been cited by other articles:

|
 |

|
 |
 
J. Koyama and R. H. Falk
Prognostic Significance of Strain Doppler Imaging in Light-Chain Amyloidosis
J. Am. Coll. Cardiol. Img.,
April 1, 2010;
3(4):
333 - 342.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Iwakura, H. Ito, S. Kawano, A. Okamura, K. Asano, T. Kuroda, K. Tanaka, T. Masuyama, M. Hori, and K. Fujii
Detection of TIMI-3 Flow Before Mechanical Reperfusion With Ultrasonic Tissue Characterization in Patients With Anterior Wall Acute Myocardial Infarction
Circulation,
July 1, 2003;
107(25):
3159 - 3164.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Koyama, P. A. Ray-Sequin, and R. H. Falk
Prognostic Significance of Ultrasound Myocardial Tissue Characterization in Patients With Cardiac Amyloidosis
Circulation,
July 30, 2002;
106(5):
556 - 561.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. E. Hancock, J. C. Cooke, D. T. Chin, and M. J. Monaghan
Determination of Successful Reperfusion After Thrombolysis for Acute Myocardial Infarction: A Noninvasive Method Using Ultrasonic Tissue Characterization That Can Be Applied Clinically
Circulation,
January 15, 2002;
105(2):
157 - 161.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Takiuchi, H. Ito, K. Iwakura, Y. Taniyama, N. Nishikawa, T. Masuyama, M. Hori, Y. Higashino, K. Fujii, and T. Minamino
Ultrasonic Tissue Characterization Predicts Myocardial Viability in Early Stage of Reperfused Acute Myocardial Infarction
Circulation,
February 3, 1998;
97(4):
356 - 362.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|