J Am Coll Cardiol, 1995; 25:1576-1583
© 1995 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Raitt, M.
Right arrow Articles by Bardy, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Raitt, M.
Right arrow Articles by Bardy, G.

Clinical predictors of the defibrillation threshold with the unipolar implantable defibrillation system

MH Raitt, G Johnson, GL Dolack, JE Poole, PJ Kudenchuk, and GH Bardy

Department of Medicine, University of Washington, Seattle, USA.

OBJECTIVES. The purpose of this study was to determine the relation between clinical variables and the defibrillation threshold by using a standardized testing protocol and a uniform implantable defibrillator system. BACKGROUND. Past studied have not revealed useful correlations between clinical variables and the energy required to terminate ventricular fibrillation. Most of these studies did not use a uniform implantable defibrillator system or a standardized protocol to measure the defibrillation threshold and, thus, did not control for the influence of these technical influences. We postulated that defibrillator and defibrillation threshold measurement-based sources of variability overshadowed important clinical predictors. METHODS. The defibrillation threshold was measured by using a standardized protocol in 101 consecutive patients. We used a transvenous unipolar pectoral defibrillation system that employed a single endocardial right ventricular defibrillation coil as the anode and the shell of an 80-cm3 pulse generator as the cathode to deliver a 65% tilt biphasic pulse. RESULTS. Several clinical variables were found to be significantly associated with the defibrillation threshold: patient gender, height, weight, body surface area, heart rate at rest, QRS and corrected QT (QTc) intervals, left ventricular mass and several measures of heart and chest size by chest roentgenogram. None of these variables had a correlation coefficient > 0.45 with the defibrillation threshold. On multivariate analysis, left ventricular mass and heart rate at rest were the only independent predictors of the defibrillation threshold and explained only 25% of the observed variability. CONCLUSIONS. Despite the use of a uniform transvenous defibrillation system and a standardized protocol to measure the defibrillation threshold, no clinically relevant correlation was found between clinical variables and the defibrillation threshold. The defibrillation threshold is probably a function of a complex interaction of anatomic, physiologic and cellular variables that are not adequately represented by easily obtainable clinical information. It is probably not possible to predict defibrillation outcome from standard clinical variables.


This article has been cited by other articles:


Home page
EuropaceHome page
J. E. Val-Mejias and A. Oza
Does defibrillation threshold increase as left ventricular ejection fraction decreases?
Europace, March 1, 2010; 12(3): 385 - 388.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
D. A.M.J. Theuns and M. R. Gold
Defibrillation threshold testing at implantation: can we predict the patient with a high defibrillation threshold?
Europace, March 1, 2010; 12(3): 309 - 310.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Cooklin, M. R. Olsovsky, R. G. Brockman, S. R. Shorofsky, and M. R. Gold
Atrial defibrillation with a transvenous lead: A randomized comparison of active can shocking pathways
J. Am. Coll. Cardiol., August 1, 1999; 34(2): 358 - 362.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
Y. Yamanouchi, K. A. Mowrey, M. J. Niebauer, P. J. Tchou, and B. L. Wilkoff
Additional Lead Improves Defibrillation Efficacy With an Abdominal `Hot Can' Electrode System
Circulation, December 16, 1997; 96(12): 4400 - 4407.
[Abstract] [Full Text]


Home page
CirculationHome page
D. Newman, A. Barr, M. Greene, D. Martin, M. Ham, S. Thorne, and P. Dorian
A Population-Based Method for the Estimation of Defibrillation Energy Requirements in Humans : Assessment of Time-Dependent Effects With a Transvenous Defibrillation System
Circulation, July 1, 1997; 96(1): 267 - 273.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement