JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1995; 25:1486-1491
© 1995 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Arnese, M
Right arrow Articles by Roelandt,
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arnese, M
Right arrow Articles by Roelandt, , JR

Quantitative angiographic measurements of isolated left anterior descending coronary artery stenosis. Correlation with exercise echocardiography and technetium-99m 2-methoxy isobutyl isonitrile single-photon emission computed tomography

M Arnese, A Salustri, PM Fioretti, JH Cornel, E Boersma, AE Reijs, PJ de Feyter, and Roelandt JR

Thoraxcenter, Erasmus University Rotterdam, The Netherlands.

OBJECTIVES. This study sought to assess the value of quantitative coronary arteriography in predicting an ischemic response at exercise echocardiography and technetium-99m 2-methoxy isobutyl isonitrile (mibi) single-photon emission computed tomography (SPECT) in patients with single-vessel disease of the left anterior descending coronary artery. BACKGROUND. The relation between severity of coronary stenosis and ischemic response to exercise echocardiography and perfusion scintigraphy in patients with single-vessel left anterior descending coronary artery disease is not well established. METHODS. Thirty-one patients without a previous myocardial infarction who had isolated stenosis of varying degrees in the proximal or midportion of the left anterior descending coronary artery were studied. Quantitative arteriographic analysis was used for measurements of percent diameter stenosis and minimal lumen diameter. Exercise-induced wall motion abnormalities by echocardiography and transient perfusion defects by mibi SPECT were considered a positive response. The analysis of sensitivity/specificity and receiver operating characteristic curves was applied to establish the diagnostic power of quantitative coronary arteriography to predict an ischemic response to exercise echocardiography and mibi SPECT. RESULTS. The "best" angiographic cutoff values for predicting a positive exercise echocardiographic and scintigraphic response were similar (diameter stenosis 52%, minimal lumen diameter 1.12 mm for echocardiography; diameter stenosis 49%, minimal lumen diameter 1.20 mm for SPECT). However, the sensitivity/specificity at the cross point was slightly higher (even if not statistically significant) for echocardiography than for SPECT, both for diameter stenosis (81% vs. 67%) and minimal lumen diameter (81% vs. 74%), suggesting that quantitative coronary arteriographic measurements are more closely related to echocardiographic than scintigraphic exercise test results. CONCLUSIONS. The functional significance of a proximal/mid-left anterior descending coronary artery stenosis measured by quantitative coronary arteriography is slightly better related to echocardiographic than scintigraphic markers of exercise-induced myocardial ischemia.


This article has been cited by other articles:


Home page
Eur Heart JHome page
P. Malagutti, K. Nieman, W. B. Meijboom, C. A.G. van Mieghem, F. Pugliese, F. Cademartiri, N. R. Mollet, E. Boersma, P. P. de Jaegere, and P. J. de Feyter
Use of 64-slice CT in symptomatic patients after coronary bypass surgery: evaluation of grafts and coronary arteries
Eur. Heart J., August 1, 2007; 28(15): 1879 - 1885.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
N. R. Mollet, F. Cademartiri, C. Van Mieghem, B. Meijboom, F. Pugliese, G. Runza, T. Baks, J. Dikkeboer, E. P. McFadden, M. P. Freericks, et al.
Adjunctive value of CT coronary angiography in the diagnostic work-up of patients with typical angina pectoris
Eur. Heart J., August 1, 2007; 28(15): 1872 - 1878.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
Y. Arad, L. A. Spadaro, K. Goodman, D. Newstein, and A. D. Guerci
Prediction of coronary events with electron beam computed tomography
J. Am. Coll. Cardiol., October 1, 2000; 36(4): 1253 - 1260.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Shimizu, T. Hirayama, H. Suesada, K. Ikeda, S. Ito, and S. Ishimaru
Effect of flow competition on internal thoracic artery graft: Postoperative velocimetric and angiographic study
J. Thorac. Cardiovasc. Surg., September 1, 2000; 120(3): 459 - 465.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. J. Scanlon, D. P. Faxon, A.-M. Audet, B. Carabello, G. J. Dehmer, K. A. Eagle, R. D. Legako, D. F. Leon, J. A. Murray, S. E. Nissen, et al.
ACC/AHA guidelines for coronary angiography: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography) developed in collaboration with the Society for Cardiac Angiography and Interventions
J. Am. Coll. Cardiol., May 1, 1999; 33(6): 1756 - 1824.
[Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1995 by the American College of Cardiology Foundation.