JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1994; 24:1779-1785
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mor-Avi, V
Right arrow Articles by Lang, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mor-Avi, V
Right arrow Articles by Lang, R.

Effects of left ventricular pressure on sonicated albumin microbubbles: evaluation using an isolated rabbit heart model

V Mor-Avi, SG Shroff, KA Robinson, AF Ng, BP Cholley, RH Marcus, and RM Lang

Department of Medicine, University of Chicago Medical Center, Illinois 60637.

OBJECTIVES: We used an isolated, crystalloid-perfused rabbit heart model to test the hypothesis that the phasic changes in left ventricular contrast are due to bubble compression and decompression during systole and diastole, respectively. BACKGROUND. Contrast enhancement of the left ventricular cavity has been shown to decrease during ventricular systole. This phenomenon has been attributed to pressure-induced microbubble destruction. Such destruction, if confirmed, would severely confound the quantitative interpretation of contrast echocardiographic data. METHODS. A fixed volume of contrast solution (5% human albumin and Albunex, approximately 400:1 ratio) was introduced into a latex balloon placed within the left ventricular cavity of an isolated paced rabbit heart preparation (n = 12). Instantaneous left ventricular pressure was measured using a high fidelity microtip catheter and digitized on-line. The beating heart was placed in a water tank, and ultrasound images were obtained using a 7.5-MHz transducer and were recorded and digitized off-line at 12 frames/s. Simultaneously, the pacing signal was used for gated on-line acquisition of end-diastolic frames. A simple theoretic model based on surface tension physical principles was used to predict changes in bubble size and, consequently, the reflection intensity in response to the measured changes in left ventricular pressure. RESULTS. We found that under peak left ventricular systolic pressures ranging from 89 to 155 mm Hg, 1) end-diastolic videointensity decreased by 8 +/- 6% (mean +/- SD) over 25 consecutive heart beats; and 2) intracyclic variations in measured videointensity were in close agreement with the theoretic calculations: 80.1 +/- 2.9% versus 80.2 +/- 4.6% of diastolic videointensity at systole. CONCLUSIONS. The major cause of systolic decrease in contrast enhancement is periodic bubble compression (as opposed to bubble destruction) induced by high systolic pressures. The minor progressive decrease in end-diastolic videointensity reflects the degree of instability of Albunex microbubbles under left ventricular pressures. However, the clinical impact of these destructive effects is likely to be only minor because of the rapid transit of microbubbles through the left heart chambers and myocardial microcirculation.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
J. L. Cohen, J. Cheirif, D. S. Segar, L. D. Gillam, J. S. Gottdiener, E. Hausnerova, and D. E. Bruns
Improved left ventricular endocardial border delineation and opacification with OPTISON (FS069), a new echocardiographic contrast agent: Results of a phase III multicenter trial
J. Am. Coll. Cardiol., September 1, 1998; 32(3): 746 - 752.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
H. D. Van Liew and S. Raychaudhuri
Stabilized bubbles in the body: pressure-radius relationships and the limits to stabilization
J Appl Physiol, June 1, 1997; 82(6): 2045 - 2053.
[Abstract] [Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1994 by the American College of Cardiology Foundation.