JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1994; 24:1688-1691
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Oz, M.
Right arrow Articles by Levin, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Oz, M.
Right arrow Articles by Levin, H.

Malignant ventricular arrhythmias are well tolerated in patients receiving long-term left ventricular assist devices

MC Oz, EA Rose, J Slater, JJ Kuiper, KA Catanese, and HR Levin

Division of Cardiac Surgery, College of Physicians and Surgeons, Columbia University, New York, New York.

OBJECTIVES. We sought to quantitate the incidence of malignant ventricular arrhythmias and to identify subsequent hemodynamic changes and untoward events in patients who have received an implantable left ventricular circulatory assist device as an extended bridge to heart transplantation. BACKGROUND. Implantable long-term mechanical circulatory assist devices have been used clinically with increasing frequency and success for the past 4 years. Previous investigators have suggested that patients with malignant ventricular arrhythmias receiving a left ventricular assist device will require both left and right ventricular assistance to maintain vital organ perfusion. METHODS. We reviewed our 4-year experience with 21 patients who underwent implantation of a left ventricular assist device. Device flows and mean arterial pressure were used to assess systemic perfusion; central venous pressure provided a gauge of right ventricular function. Charts were screened for evidence of end-organ injury resulting from malignant ventricular arrhythmias. RESULTS. Malignant ventricular arrhythmias occurred in 4 patients (19%) before device placement and in 9 patients (43%) during device support. The latter nine patients formed the final study group; their arrhythmias occurred 0 to 186 days after device implantation and had a duration of 10 min to 12 days. The patients reported weakness or palpitation; however, none reported syncope or dyspnea. Mean arterial pressure and central venous pressure were insignificantly changed by the arrhythmias. Device flow decreased by 1.4 +/- 0.6 liters/min (p < 0.05) at the onset of the arrhythmias but returned to normal after cardioversion. No thromboembolic events or significant end-organ dysfunction occurred. CONCLUSION. Absence of right ventricular contraction during malignant ventricular arrhythmias is well tolerated in recipients of a left ventricular assist device. The diagnosis of malignant arrhythmia should be suspected if an unexplained decrease in left ventricular assist device flow occurs. Early electrical cardioversion is warranted to avoid both thrombus formation in the native heart and right ventricular myocardial injury from prolonged fibrillation.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
S. Aggarwal, F. Cheema, M. C. Oz, and Y. Naka
Long-Term Mechanical Circulatory Support
Card. Surg. Adult, January 1, 2008; 3(2008): 1609 - 1628.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
L. Zhang, E. I. Kapetanakis, R. H. Cooke, L. C. Sweet, and S. W. Boyce
Bi-Ventricular Circulatory Support With the Abiomed AB5000 System in a Patient With Idiopathic Refractory Ventricular Fibrillation
Ann. Thorac. Surg., January 1, 2007; 83(1): 298 - 300.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
F. Collart, P. Dieuzaide, F. Kerbaul, A. Mouly-Bandini, and T. G. Mesana
Complete Atrioventricular Block Decreases Left Ventricular Assist Device Flow Rate
Ann. Thorac. Surg., August 1, 2005; 80(2): 716 - 717.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
O. Ziv, J. Dizon, A. Thosani, Y. Naka, A. R. Magnano, and H. Garan
Effects of Left Ventricular Assist Device Therapy on Ventricular Arrhythmias
J. Am. Coll. Cardiol., May 3, 2005; 45(9): 1428 - 1434.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Nishimura, M. Ogiwara, M. Ishikawa, S. Yatsu, A. Masuoka, N. Okamura, K. Imanaka, M. Kato, H. Asano, and S. Kyo
Fifteen-month circulatory support for sustained ventricular fibrillation by left ventricular assist device
J. Thorac. Cardiovasc. Surg., October 1, 2003; 126(4): 1190 - 1192.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. D. Aaronson, H. Patel, and F. D. Pagani
Patient selection for left ventricular assist device therapy
Ann. Thorac. Surg., June 1, 2003; 75(90060): S29 - 35.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. C. Sun, K. A. Catanese, T. B. Spanier, M. R. Flannery, M. T. Gardocki, L. S. Marcus, H. R. Levin, E. A. Rose, and M. C. Oz
100 long-term implantable left ventricular assist devices: the Columbia Presbyterian interim experience
Ann. Thorac. Surg., August 1, 1999; 68(2): 688 - 694.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. M. Chen, J. J. DeRose, J. P. Slater, T. B. Spanier, T. M. Dewey, K. A. Catanese, M. A. Flannery, and M. C. Oz
Improved survival rates support left ventricular assist device implantation early after myocardial infarction
J. Am. Coll. Cardiol., June 1, 1999; 33(7): 1903 - 1908.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
D. J. Goldstein, M. C. Oz, and E. A. Rose
Implantable Left Ventricular Assist Devices
N. Engl. J. Med., November 19, 1998; 339(21): 1522 - 1533.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. M. Kulick, R. M. Bolman III, C. T. Salerno, A. J. Bank, and S. J. Park
Management of recurrent ventricular tachycardia with ventricular assist device placement
Ann. Thorac. Surg., August 1, 1998; 66(2): 571 - 573.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
MehmetC. Oz, M. Argenziano, K. A. Catanese, M. T. Gardocki, D. J. Goldstein, R. C. Ashton, A. C. Gelijns, E. A. Rose, and H. R. Levin
Bridge Experience With Long-term Implantable Left Ventricular Assist Devices: Are They an Alternative to Transplantation?
Circulation, April 1, 1997; 95(7): 1844 - 1852.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1994 by the American College of Cardiology Foundation.