Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1994; 24:1475-1481
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Plante, S
Right arrow Articles by Chisholm, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Plante, S
Right arrow Articles by Chisholm, R.

Reuse of balloon catheters for coronary angioplasty: a potential cost-saving strategy?

S Plante, BH Strauss, G Goulet, RK Watson, and RJ Chisholm

Division of Cardiology, Centre Hospitalier Universitaire de Sherbrooke, Canada.

OBJECTIVES. This study was designed to determine the effectiveness, safety and costs associated with reuse of angioplasty catheters and to compare these results with those of a contemporary center that employed a single-use strategy. BACKGROUND. Coronary angioplasty is an important but expensive procedure. To overcome the financial constraints of the Canadian health care system, reuse of angioplasty catheters is routinely practiced in some institutions. METHODS. In a prospective observational study, data forms were completed after each angioplasty procedure and before patient discharge over a 10-month period. RESULTS. A total of 693 patients underwent coronary angioplasty in the two centers. Clinical and lesion characteristics were similar except for a higher incidence of unstable angina at the reuse center (p < 0.005). The angiographic success rate was identical (88%) at both centers. The reuse center utilized more balloon catheters/lesion (mean +/- SD 2.4 +/- 1.5 vs. 1.2 +/- 0.5, p < 0.00001) and had a higher incidence of initial balloon failure (10.2% vs. 3.3%, p < 0.0001). Significant prolongation of the procedure time (81 +/- 41 vs. 68 +/- 32 min, p < 0.0001) and increased volume of contrast medium (201 +/- 86 vs. 165 +/- 61 ml, p < 0.0001) were seen in the reuse center. A higher rate of adverse clinical events (7.8% vs. 3.8%, p < 0.025) was observed in the reuse center, especially in patients with unstable angina. CONCLUSIONS. The reuse strategy was associated with a higher rate of adverse events, prolonged procedure time and increased use of contrast medium, especially in lesions that were not crossed by the initial balloon and in patients with unstable angina. Whether these differences are related to the reuse strategy or to differences in patient groups cannot be ascertained by this observational study. A multicenter randomized trial is required to further assess the safety and the cost/benefit ratio of this strategy.


This article has been cited by other articles:


Home page
Eur Heart JHome page
D.S Luijt, J Schirm, P.H.M Savelkoul, and A Hoekstra
Risk of infection by reprocessed and resterilized virus-contaminated catheters; an in-vitro study
Eur. Heart J., March 1, 2001; 22(5): 378 - 384.
[Abstract] [PDF]


Home page
J Biomater ApplHome page
D. Behrend, G. Zinner, K. Sternberg, M. Schroeder, K. P. Schmitz, and A. Haubold
Assessment of Explanted PTCA Balloons
J Biomater Appl, October 1, 2000; 15(2): 160 - 167.
[Abstract] [PDF]


Home page
Eur Heart JHome page
G. Krause, G. Dziekan, and F.D. Daschner
Reuse of coronary angioplasty balloon catheters: yes or no?
Eur. Heart J., February 1, 2000; 21(3): 185 - 189.
[PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. F. Bloom, J. F. Cornhill, P. S. Malchesky, D. M. Richardson, K. A. Bolsen, D. M. Haire, F. D. Loop, and D. M. Cosgrove III
TECHNICAL AND ECONOMIC FEASIBILITY OF REUSING DISPOSABLE PERFUSION CANNULAS
J. Thorac. Cardiovasc. Surg., September 1, 1997; 114(3): 448 - 460.
[Abstract] [Full Text]


Home page
CirculationHome page
S. G. Ellis, D. P. Miller, K. J. Brown, N. Omoigui, G. L. Howell, M. Kutner, and E. J. Topol
In-Hospital Cost of Percutaneous Coronary Revascularization : Critical Determinants and Implications
Circulation, August 15, 1995; 92(4): 741 - 747.
[Abstract] [Full Text]


Home page
Journal Watch CardiologyHome page
Is Reuse of Angioplasty Balloon Catheters Safe?
Journal Watch Cardiology, January 1, 1995; 1995(101): 20 - 20.
[Full Text]


Home page
JWatch GeneralHome page
REUSE OF ANGIOPLASTY BALLOON CATHETERS: COSTS AND RISKS
Journal Watch (General), November 18, 1994; 1994(1118): 7 - 7.
[Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement