JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1994; 24:1207-1212
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Savage, M.
Right arrow Articles by Cleman, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Savage, M.
Right arrow Articles by Cleman, M.

Long-term angiographic and clinical outcome after implantation of a balloon-expandable stent in the native coronary circulation. Palmaz-Schatz Stent Study Group

MP Savage, DL Fischman, RA Schatz, PS Teirstein, MB Leon, D Baim, SG Ellis, EJ Topol, JW Hirshfeld, MW Cleman, et al.

Department of Medicine, Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107.

OBJECTIVES. The purpose of this study was to examine the long-term clinical and angiographic outcome after coronary stent implantation. BACKGROUND. Previous reports have shown a discordance between the excellent initial angiographic results and subsequent adverse clinical events after coronary artery stenting. METHODS. Single Palmaz-Schatz stents were electively implanted in the native coronary arteries of 300 consecutive patients. Angiograms were obtained at baseline, after balloon angioplasty, after stent implantation and at 6 months after implantation. Films were analyzed by a panel of angiographers utilizing an automated edge detection program. Clinical events, including death, myocardial infarction, coronary bypass surgery and repeat angioplasty, were recorded for 1 year. RESULTS. Although there were no acute in laboratory vessel closures, stent thrombosis occurred in 14 patients (4.7%) at a mean +/- SD of 5 +/- 3 days after implantation. Two hundred fifty-eight (90%) of 286 eligible patients had follow-up angiography at 6.1 +/- 2.2 months after stent implantation. Minimal lumen diameter increased from 0.80 +/- 0.39 mm at baseline to 1.65 +/- 0.51 mm after angioplasty and further increased to 2.55 +/- 0.49 mm after stent placement (p = 0.0001). At follow-up there was a 0.85-mm late loss in lumen diameter, with a final minimal lumen diameter at 6 months of 1.70 +/- 0.71 mm. Restenosis, defined as > or = 50% diameter stenosis at follow-up, occurred in 14% of patients with previously untreated lesions and in 39% of patients with previous angioplasty (p < 0.001). Clinical events after 1 year for the entire group of 300 patients included death in 0.7%, myocardial infarction in 3.7%, bypass grafting in 8% and repeat angioplasty in 13%. Freedom from any adverse clinical event was 80% for all treated patients and 87% for those with previously untreated lesions. CONCLUSIONS. Elective use of this balloon-expandable stent in the native coronary circulation is associated with a low restenosis rate by quantitative angiography in previously untreated lesions and a favorable clinical outcome with an excellent event-free survival rate at 1 year.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
V. Schachinger, C. W. Hamm, T. Munzel, M. Haude, S. Baldus, E. Grube, T. Bonzel, T. Konorza, R. Koster, R. Arnold, et al.
A randomized trial of polytetrafluoroethylene-membrane-covered stents compared with conventional stents in aortocoronary saphenous vein grafts
J. Am. Coll. Cardiol., October 15, 2003; 42(8): 1360 - 1369.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. Inoue, T. Uchida, I. Yaguchi, Y. Sakai, K. Takayanagi, and S. Morooka
Stent-Induced Expression and Activation of the Leukocyte Integrin Mac-1 Is Associated With Neointimal Thickening and Restenosis
Circulation, April 8, 2003; 107(13): 1757 - 1763.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M.G Bourassa, K.M Detre, J.M Johnston, H.A Vlachos, and R Holubkov
Effect of prior revascularization on outcome following percutaneous coronary intervention. NHLBI Dynamic Registry
Eur. Heart J., October 1, 2002; 23(19): 1546 - 1555.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. E. Cutlip, D. S. Baim, K. K. L. Ho, J. J. Popma, A. J. Lansky, D. J. Cohen, J. P. Carrozza Jr, M. S. Chauhan, O. Rodriguez, and R. E. Kuntz
Stent Thrombosis in the Modern Era : A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Circulation, April 17, 2001; 103(15): 1967 - 1971.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
I. P. Kay, A. J. Wardeh, K. Kozuma, D. P. Foley, A. H. M. Knook, A. Thury, G. Sianos, W. J. van der Giessen, P. C. Levendag, and P. W. Serruys
Radioactive Stents Delay but Do Not Prevent In-Stent Neointimal Hyperplasia
Circulation, January 2, 2001; 103(1): 14 - 17.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Baldus, R. Koster, M. Elsner, D. H. Walter, R. Arnold, W. Auch-Schwelk, J. Berger, M. Rau, T. Meinertz, A. M. Zeiher, et al.
Treatment of Aortocoronary Vein Graft Lesions With Membrane-Covered Stents : A Multicenter Surveillance Trial
Circulation, October 24, 2000; 102(17): 2024 - 2027.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
A. M. Lincoff
Stent Scrutiny
JAMA, October 11, 2000; 284(14): 1839 - 1841.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. H. Grewe, T. Deneke, A. Machraoui, J.u. Barmeyer, and K.-M. Muller
Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen
J. Am. Coll. Cardiol., January 1, 2000; 35(1): 157 - 163.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. G. Webb, R. G. Carere, R. Virmani, D. Baim, P. S. Teirstein, P. Whitlow, C. McQueen, F. D. Kolodgie, E. Buller, A. Dodek, et al.
Retrieval and analysis of particulate debris after saphenous vein graft intervention
J. Am. Coll. Cardiol., August 1, 1999; 34(2): 468 - 475.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. Kasaoka, J. M. Tobis, T. Akiyama, B. Reimers, C. Di Mario, N. D. Wong, and A. Colombo
Angiographic and intravascular ultrasound predictors of in-stent restenosis
J. Am. Coll. Cardiol., November 15, 1998; 32(6): 1630 - 1635.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. P. Jain, S. R. Ramee, C. J. White, M. R. Mehra, H. O. Ventura, S. Zhang, J. S. Jenkins, and T. J. Collins
Coronary stenting in cardiac allograft vasculopathy
J. Am. Coll. Cardiol., November 15, 1998; 32(6): 1636 - 1640.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
A L Calver, K D Dawkins, H H Gray, G A Haywood, J M Morgan, and I A Simpson
Intracoronary Multi-link stents: experience in 218 patients using aspirin alone
Heart, November 1, 1998; 80(5): 499 - 504.
[Abstract] [Full Text]


Home page
Cardiovasc ResHome page
S.D. Gertz, W. L Barry, L. W Gimple, Shmuel Banai, L. S Perez, C. A McNamara, E. R Powers, M. Ragosta, G. K Owens, W. C Roberts, et al.
Predictors of luminal narrowing by neointima after angioplasty in atherosclerotic rabbits
Cardiovasc Res, December 1, 1997; 36(3): 396 - 407.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
M. P. Savage, J. S. Douglas, D. L. Fischman, C. J. Pepine, S. B. King, J. A. Werner, S. R. Bailey, P. A. Overlie, S. H. Fenton, J. A. Brinker, et al.
Stent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass Grafts
N. Engl. J. Med., September 11, 1997; 337(11): 740 - 747.
[Abstract] [Full Text] [PDF]


Home page
CLIN APPL THROMB HEMOSTHome page
G. Franco Gensini, A. Colella, and M. Comeglio
State-of-the-Art Review: Antiplatelet Agents and Thrombin Inhibitors: Combined Modality Therapy
Clinical and Applied Thrombosis/Hemostasis, April 1, 1997; 3(2): 82 - 85.
[PDF]


Home page
CirculationHome page
R. R. Makkar, F. Litvack, N. L. Eigler, M. Nakamura, P. A. Ivey, J. S. Forrester, P. K. Shah, R. E. Jordan, and S. Kaul
Effects of GP IIb/IIIa Receptor Monoclonal Antibody (7E3), Heparin, and Aspirin in an Ex Vivo Canine Arteriovenous Shunt Model of Stent Thrombosis
Circulation, February 18, 1997; 95(4): 1015 - 1021.
[Abstract] [Full Text]


Home page
CirculationHome page
S. Sheth, F. Litvack, V. Dev, M. C. Fishbein, J. S. Forrester, and N. Eigler
Subacute Thrombosis and Vascular Injury Resulting From Slotted-Tube Nitinol and Stainless Steel Stents in a Rabbit Carotid Artery Model
Circulation, October 1, 1996; 94(7): 1733 - 1740.
[Abstract] [Full Text]


Home page
CirculationHome page
P. N. Ruygrok and P. W. Serruys
Intracoronary Stenting: From Concept to Custom
Circulation, September 1, 1996; 94(5): 882 - 890.
[Full Text]


Home page
CirculationHome page
Y. Ozaki, D. Keane, P. Ruygrok, W. J. van der Giessen, P. de Feyter, and P. W. Serruys
Six-Month Clinical and Angiographic Outcome of the New, Less Shortening Wallstent in Native Coronary Arteries
Circulation, June 15, 1996; 93(12): 2114 - 2120.
[Abstract] [Full Text]


Home page
NEJMHome page
T. Kimura, H. Yokoi, Y. Nakagawa, T. Tamura, S. Kaburagi, Y. Sawada, Y. Sato, H. Yokoi, N. Hamasaki, H. Nosaka, et al.
Three-Year Follow-Up after Implantation of Metallic Coronary-Artery Stents
N. Engl. J. Med., February 29, 1996; 334(9): 561 - 567.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
J. A. Bittl, L. Schwartz, P. W. Serruys, The Benestent Investigators, D. L. Fischman, M. P. Savage, S. Goldberg, and E. J. Topol
Coronary-Stent Placement Compared with Balloon Angioplasty
N. Engl. J. Med., February 23, 1995; 332(8): 536 - 538.
[Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1994 by the American College of Cardiology Foundation.