Long-term angiographic and clinical outcome after implantation of a balloon-expandable stent in the native coronary circulation. Palmaz-Schatz Stent Study Group
MP Savage,
DL Fischman,
RA Schatz,
PS Teirstein,
MB Leon,
D Baim,
SG Ellis,
EJ Topol,
JW Hirshfeld,
MW Cleman,
et al.
Department of Medicine, Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107.
OBJECTIVES. The purpose of this study was to examine the long-term clinical and angiographic outcome after coronary stent implantation. BACKGROUND. Previous reports have shown a discordance between the excellent initial angiographic results and subsequent adverse clinical events after coronary artery stenting. METHODS. Single Palmaz-Schatz stents were electively implanted in the native coronary arteries of 300 consecutive patients. Angiograms were obtained at baseline, after balloon angioplasty, after stent implantation and at 6 months after implantation. Films were analyzed by a panel of angiographers utilizing an automated edge detection program. Clinical events, including death, myocardial infarction, coronary bypass surgery and repeat angioplasty, were recorded for 1 year. RESULTS. Although there were no acute in laboratory vessel closures, stent thrombosis occurred in 14 patients (4.7%) at a mean +/- SD of 5 +/- 3 days after implantation. Two hundred fifty-eight (90%) of 286 eligible patients had follow-up angiography at 6.1 +/- 2.2 months after stent implantation. Minimal lumen diameter increased from 0.80 +/- 0.39 mm at baseline to 1.65 +/- 0.51 mm after angioplasty and further increased to 2.55 +/- 0.49 mm after stent placement (p = 0.0001). At follow-up there was a 0.85-mm late loss in lumen diameter, with a final minimal lumen diameter at 6 months of 1.70 +/- 0.71 mm. Restenosis, defined as > or = 50% diameter stenosis at follow-up, occurred in 14% of patients with previously untreated lesions and in 39% of patients with previous angioplasty (p < 0.001). Clinical events after 1 year for the entire group of 300 patients included death in 0.7%, myocardial infarction in 3.7%, bypass grafting in 8% and repeat angioplasty in 13%. Freedom from any adverse clinical event was 80% for all treated patients and 87% for those with previously untreated lesions. CONCLUSIONS. Elective use of this balloon-expandable stent in the native coronary circulation is associated with a low restenosis rate by quantitative angiography in previously untreated lesions and a favorable clinical outcome with an excellent event-free survival rate at 1 year.
This article has been cited by other articles:

|
 |

|
 |
 
V. Schachinger, C. W. Hamm, T. Munzel, M. Haude, S. Baldus, E. Grube, T. Bonzel, T. Konorza, R. Koster, R. Arnold, et al.
A randomized trial of polytetrafluoroethylene-membrane-covered stents compared with conventional stents in aortocoronary saphenous vein grafts
J. Am. Coll. Cardiol.,
October 15, 2003;
42(8):
1360 - 1369.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. Inoue, T. Uchida, I. Yaguchi, Y. Sakai, K. Takayanagi, and S. Morooka
Stent-Induced Expression and Activation of the Leukocyte Integrin Mac-1 Is Associated With Neointimal Thickening and Restenosis
Circulation,
April 8, 2003;
107(13):
1757 - 1763.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M.G Bourassa, K.M Detre, J.M Johnston, H.A Vlachos, and R Holubkov
Effect of prior revascularization on outcome following percutaneous coronary intervention. NHLBI Dynamic Registry
Eur. Heart J.,
October 1, 2002;
23(19):
1546 - 1555.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. E. Cutlip, D. S. Baim, K. K. L. Ho, J. J. Popma, A. J. Lansky, D. J. Cohen, J. P. Carrozza Jr, M. S. Chauhan, O. Rodriguez, and R. E. Kuntz
Stent Thrombosis in the Modern Era : A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Circulation,
April 17, 2001;
103(15):
1967 - 1971.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
I. P. Kay, A. J. Wardeh, K. Kozuma, D. P. Foley, A. H. M. Knook, A. Thury, G. Sianos, W. J. van der Giessen, P. C. Levendag, and P. W. Serruys
Radioactive Stents Delay but Do Not Prevent In-Stent Neointimal Hyperplasia
Circulation,
January 2, 2001;
103(1):
14 - 17.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Baldus, R. Koster, M. Elsner, D. H. Walter, R. Arnold, W. Auch-Schwelk, J. Berger, M. Rau, T. Meinertz, A. M. Zeiher, et al.
Treatment of Aortocoronary Vein Graft Lesions With Membrane-Covered Stents : A Multicenter Surveillance Trial
Circulation,
October 24, 2000;
102(17):
2024 - 2027.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. M. Lincoff
Stent Scrutiny
JAMA,
October 11, 2000;
284(14):
1839 - 1841.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
P. H. Grewe, T. Deneke, A. Machraoui, J.u. Barmeyer, and K.-M. Muller
Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen
J. Am. Coll. Cardiol.,
January 1, 2000;
35(1):
157 - 163.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. G. Webb, R. G. Carere, R. Virmani, D. Baim, P. S. Teirstein, P. Whitlow, C. McQueen, F. D. Kolodgie, E. Buller, A. Dodek, et al.
Retrieval and analysis of particulate debris after saphenous vein graft intervention
J. Am. Coll. Cardiol.,
August 1, 1999;
34(2):
468 - 475.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Kasaoka, J. M. Tobis, T. Akiyama, B. Reimers, C. Di Mario, N. D. Wong, and A. Colombo
Angiographic and intravascular ultrasound predictors of in-stent restenosis
J. Am. Coll. Cardiol.,
November 15, 1998;
32(6):
1630 - 1635.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. P. Jain, S. R. Ramee, C. J. White, M. R. Mehra, H. O. Ventura, S. Zhang, J. S. Jenkins, and T. J. Collins
Coronary stenting in cardiac allograft vasculopathy
J. Am. Coll. Cardiol.,
November 15, 1998;
32(6):
1636 - 1640.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A L Calver, K D Dawkins, H H Gray, G A Haywood, J M Morgan, and I A Simpson
Intracoronary Multi-link stents: experience in 218 patients using aspirin alone
Heart,
November 1, 1998;
80(5):
499 - 504.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
S.D. Gertz, W. L Barry, L. W Gimple, Shmuel Banai, L. S Perez, C. A McNamara, E. R Powers, M. Ragosta, G. K Owens, W. C Roberts, et al.
Predictors of luminal narrowing by neointima after angioplasty in atherosclerotic rabbits
Cardiovasc Res,
December 1, 1997;
36(3):
396 - 407.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. P. Savage, J. S. Douglas, D. L. Fischman, C. J. Pepine, S. B. King, J. A. Werner, S. R. Bailey, P. A. Overlie, S. H. Fenton, J. A. Brinker, et al.
Stent Placement Compared with Balloon Angioplasty for Obstructed Coronary Bypass Grafts
N. Engl. J. Med.,
September 11, 1997;
337(11):
740 - 747.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Franco Gensini, A. Colella, and M. Comeglio
State-of-the-Art Review: Antiplatelet Agents and Thrombin Inhibitors: Combined Modality Therapy
Clinical and Applied Thrombosis/Hemostasis,
April 1, 1997;
3(2):
82 - 85.
[PDF]
|
 |
|

|
 |

|
 |
 
R. R. Makkar, F. Litvack, N. L. Eigler, M. Nakamura, P. A. Ivey, J. S. Forrester, P. K. Shah, R. E. Jordan, and S. Kaul
Effects of GP IIb/IIIa Receptor Monoclonal Antibody (7E3), Heparin, and Aspirin in an Ex Vivo Canine Arteriovenous Shunt Model of Stent Thrombosis
Circulation,
February 18, 1997;
95(4):
1015 - 1021.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
S. Sheth, F. Litvack, V. Dev, M. C. Fishbein, J. S. Forrester, and N. Eigler
Subacute Thrombosis and Vascular Injury Resulting From Slotted-Tube Nitinol and Stainless Steel Stents in a Rabbit Carotid Artery Model
Circulation,
October 1, 1996;
94(7):
1733 - 1740.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
P. N. Ruygrok and P. W. Serruys
Intracoronary Stenting: From Concept to Custom
Circulation,
September 1, 1996;
94(5):
882 - 890.
[Full Text]
|
 |
|

|
 |

|
 |
 
Y. Ozaki, D. Keane, P. Ruygrok, W. J. van der Giessen, P. de Feyter, and P. W. Serruys
Six-Month Clinical and Angiographic Outcome of the New, Less Shortening Wallstent in Native Coronary Arteries
Circulation,
June 15, 1996;
93(12):
2114 - 2120.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
T. Kimura, H. Yokoi, Y. Nakagawa, T. Tamura, S. Kaburagi, Y. Sawada, Y. Sato, H. Yokoi, N. Hamasaki, H. Nosaka, et al.
Three-Year Follow-Up after Implantation of Metallic Coronary-Artery Stents
N. Engl. J. Med.,
February 29, 1996;
334(9):
561 - 567.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. A. Bittl, L. Schwartz, P. W. Serruys, The Benestent Investigators, D. L. Fischman, M. P. Savage, S. Goldberg, and E. J. Topol
Coronary-Stent Placement Compared with Balloon Angioplasty
N. Engl. J. Med.,
February 23, 1995;
332(8):
536 - 538.
[Full Text]
|
 |
|
|