Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1994; 24:1054-1063
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sapin, P.
Right arrow Articles by King, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sapin, P.
Right arrow Articles by King, D.

Comparison of two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients

PM Sapin, KM Schroder, AS Gopal, MD Smith, AN DeMaria, and DL King

Division of Cardiology, University of Kentucky Medical Center, Lexington 40536.

OBJECTIVES. We compared two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patients. BACKGROUND. Three-dimensional echocardiography has been shown to be highly accurate and superior to two-dimensional echocardiography in measuring left ventricular volume in vitro. However, there has been little comparison of the two methods in patients. METHODS. Two- and three-dimensional echocardiography were performed in 35 patients (mean age 48 years) 1 to 3 h before left ventricular cineventriculography. Three-dimensional echocardiography used an acoustic spatial locator to register image position. Volume was computed using a polyhedral surface reconstruction algorithm based on multiple nonparallel, unevenly spaced short-axis cross sections. Two-dimensional echocardiography used the apical biplane summation of disks method. Single-plane cineventriculographic volumes were calculated using the summation of disks algorithm. The methods were compared by linear regression and a limits of agreement analysis. For the latter, systematic error was assessed by the mean of the differences (cineventriculography minus echocardiography), and the limits of agreement were defined as +/- 2 SD from the mean difference. RESULTS. Three-dimensional echocardiographic volumes demonstrated excellent correlation (end-diastole r = 0.97; end-systole r = 0.98) with cineventriculography. Standard errors of the estimate were approximately half of those of two-dimensional echocardiography (end-diastole +/- 11.0 ml vs. +/- 21.5 ml; end-systole +/- 10.2 ml vs. +/- 17.0 ml). By limits of agreement analysis the end-diastolic mean differences for two- and three-dimensional echocardiography were 21.1 and 12.9 ml, respectively. The limits of agreement (+/- 2 SD) were +/- 54.0 and +/- 24.8 ml, respectively. For end-systole, comparable improvement was obtained by three-dimensional echocardiography. Results for ejection fraction by the two methods were similar. CONCLUSIONS. Three-dimensional echocardiography correlates highly with cineventriculography for estimation of ventricular volumes in patients and has approximately half the variability of two-dimensional echocardiography for these measurements. On the basis of this study, three-dimensional echocardiography is the preferred echocardiographic technique for measurement of ventricular volume. Three-dimensional echocardiography is equivalent to two-dimensional echocardiography for measuring ejection fraction.


This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
T. Geisler, H.C. Rost, P.S. Wild, and R. Zotz
Freehand three-dimensional assessment of left ventricular volumes and ejection fraction with ultrasound contrast agent LK565
Eur J Echocardiogr, January 1, 2007; 8(1): 19 - 29.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. M. Lang, V. Mor-Avi, L. Sugeng, P. S. Nieman, and D. J. Sahn
Three-Dimensional Echocardiography: The Benefits of the Additional Dimension
J. Am. Coll. Cardiol., November 21, 2006; 48(10): 2053 - 2069.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. C. Houck, J. E. Cooke, and E. A. Gill
Live 3D Echocardiography: A Replacement for Traditional 2D Echocardiography?
Am. J. Roentgenol., October 1, 2006; 187(4): 1092 - 1106.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. Eerola, E. Jokinen, T. Boldt, and J. Pihkala
The Influence of Percutaneous Closure of Patent Ductus Arteriosus on Left Ventricular Size and Function: A Prospective Study Using Two- and Three-Dimensional Echocardiography and Measurements of Serum Natriuretic Peptides
J. Am. Coll. Cardiol., March 7, 2006; 47(5): 1060 - 1066.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. D. Jacobs, I. S. Salgo, S. Goonewardena, L. Weinert, P. Coon, D. Bardo, O. Gerard, P. Allain, J. L. Zamorano, L. P. de Isla, et al.
Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data
Eur. Heart J., February 2, 2006; 27(4): 460 - 468.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
E G Caiani, C Corsi, L Sugeng, P MacEneaney, L Weinert, V Mor-Avi, and R M Lang
Improved quantification of left ventricular mass based on endocardial and epicardial surface detection with real time three dimensional echocardiography
Heart, February 1, 2006; 92(2): 213 - 219.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
T. Buck and R. Erbel
Should contrast be routinely used for echocardiographic assessment of left ventricular function? A matter of appropriateness
Eur. Heart J., March 2, 2005; 26(6): 534 - 535.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. P. Kuhl, M. Schreckenberg, D. Rulands, M. Katoh, W. Schafer, G. Schummers, A. Bucker, P. Hanrath, and A. Franke
High-resolution transthoracic real-time three-dimensional echocardiography: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging
J. Am. Coll. Cardiol., June 2, 2004; 43(11): 2083 - 2090.
[Abstract] [Full Text] [PDF]


Home page
Eur J Heart FailHome page
G. A. Whalley, G. D. Gamble, H. J. Walsh, S. P. Wright, S. Agewall, N. Sharpe, and R. N. Doughty
Effect of tissue harmonic imaging and contrast upon between observer and test-retest reproducibility of left ventricular ejection fraction measurement in patients with heart failure
Eur J Heart Fail, January 1, 2004; 6(1): 85 - 93.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
L Sugeng, L Weinert, and R M Lang
Left ventricular assessment using real time three dimensional echocardiography
Heart, November 1, 2003; 89(90003): iii29 - 36.
[Full Text] [PDF]


Home page
Eur Heart JHome page
R. De Simone, G. Glombitza, C.F. Vahl, H.P. Meinzer, and S. Hagl
Three-dimensional Doppler. Techniques and clinical applications
Eur. Heart J., April 2, 1999; 20(8): 619 - 627.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. De Simone, G. Glombitza, C.-F. Vahl, J. Albers, H.-P. Meinzer, and S. Hagl
Assessment of mitral regurgitant jets by three-dimensional color Doppler
Ann. Thorac. Surg., February 1, 1999; 67(2): 494 - 499.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. Buck, P. Hunold, K. U. Wentz, W. Tkalec, H. J. Nesser, and R. Erbel
Tomographic Three-dimensional Echocardiographic Determination of Chamber Size and Systolic Function in Patients With Left Ventricular Aneurysm : Comparison to Magnetic Resonance Imaging, Cineventriculography, and Two-dimensional Echocardiography
Circulation, December 16, 1997; 96(12): 4286 - 4297.
[Abstract] [Full Text]


Home page
Arch SurgHome page
P. S. Barie
Advances in Critical Care Monitoring
Arch Surg, July 1, 1997; 132(7): 734 - 739.
[Abstract] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
E. K. Louie and D. S. Louie
New Echocardiographic Technology: Does it Add to Clinical Decision-Making?
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 1997; 1(1): 16 - 31.
[PDF]


Home page
CirculationHome page
D. Gilon, E. G. Cape, M. D. Handschumacher, L. Jiang, C. Sears, J. Solheim, E. Morris, J. T. Strobel, S. M. Miller-Jones, A. E. Weyman, et al.
Insights From Three-dimensional Echocardiographic Laser Stereolithography: Effect of Leaflet Funnel Geometry on the Coefficient of Orifice Contraction, Pressure Loss, and the Gorlin Formula in Mitral Stenosis
Circulation, August 1, 1996; 94(3): 452 - 459.
[Abstract] [Full Text]


Home page
CirculationHome page
Y. F.M. Nosir, P. M. Fioretti, W. B. Vletter, E. Boersma, A. Salustri, J. T. Postma, A. E.M. Reijs, F. J. Ten Cate, and J. R.T.C. Roelandt
Accurate Measurement of Left Ventricular Ejection Fraction by Three-dimensional Echocardiography: A Comparison With Radionuclide Angiography
Circulation, August 1, 1996; 94(3): 460 - 466.
[Abstract] [Full Text]


Home page
CirculationHome page
A. S. Gopal, Z. Shen, P. M. Sapin, A. M. Keller, M. J. Schnellbaecher, D. W. Leibowitz, O. O. Akinboboye, R. A. Rodney, D. K. Blood, and D. L. King
Assessment of Cardiac Function by Three-dimensional Echocardiography Compared With Conventional Noninvasive Methods
Circulation, August 15, 1995; 92(4): 842 - 853.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement