JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1994; 24:676-682
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bortolotti, U
Right arrow Articles by Casarotto, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bortolotti, U
Right arrow Articles by Casarotto, D

Hancock II porcine bioprosthesis: excellent durability at intermediate-term follow-up

U Bortolotti, A Milano, E Mazzaro, G Thiene, E Talenti, and D Casarotto

Department of Cardiovascular Surgery, University of Padova Medical School, Italy.

OBJECTIVES. This study aimed to assess the clinical performance and durability of a new generation of porcine valve, the Hancock II bioprosthesis, at intermediate-term follow-up. BACKGROUND. Standard porcine bioprostheses undergo progressive structural deterioration, mainly due to cusp and commissural calcification, affecting durability and requiring reoperation. The Hancock II bioprosthesis, which is currently undergoing clinical investigation, is made from a porcine aortic valve treated with a calcium-retarding agent (sodium dodecyl sulfate [T6]), which should delay onset of calcification and increase durability. METHODS. From May 1983 to December 1992, we used the Hancock II bioprothesis in aortic (59 patients), mitral (101 patients) and mitral-aortic (25 patients), valve replacement procedures. Postoperative follow-up ranged from 0.1 to 8.7 years (mean [+/- SD] 4.5 +/- 2.6 years) and was 100% complete. Freedom from major postoperative events was calculated at 7 years for patients with aortic valve replacement and at 8 years for those with mitral and mitral-aortic valve replacement. RESULTS. The actuarial survival rate was 48 +/- 10%, 76 +/- 3% and 63 +/- 6%; freedom from valve-related mortality was 91 +/- 4%, 94 +/- 2% and 89 +/- 6%; freedom from thromboembolism was 80 +/- 11%, 90 +/- 2% and 79 +/- 7%; and freedom from reoperation was 100%, 97 +/- 1% and 89 +/- 6% after aortic, mitral and mitral-aortic valve replacement, respectively. No structural valve deterioration occurred. CONCLUSIONS. At intermediate-term follow-up the Hancock II bioprosthesis showed excellent durability in all positions. However, the effectiveness of anticalcification treatment must be assessed with longer follow-up studies.


This article has been cited by other articles:


Home page
Card Surg AdultHome page
N. D. Desai and G. T. Christakis
Bioprosthetic Aortic Valve Replacement: Stented Pericardial and Porcine Valves
Card. Surg. Adult, January 1, 2008; 3(2008): 857 - 894.
[Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. Rizzoli, T. Bottio, G. Thiene, G. Toscano, and D. Casarotto
Long-term durability of the Hancock II porcine bioprosthesis
J. Thorac. Cardiovasc. Surg., July 1, 2003; 126(1): 66 - 74.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Bottio, G. Thiene, E. Pettenazzo, P. Ius, U. Bortolotti, G. Rizzoli, C. Valfre, D. Casarotto, and M. Valente
Hancock II bioprosthesis: A glance at the microscope in mid-long-term explants
J. Thorac. Cardiovasc. Surg., July 1, 2003; 126(1): 99 - 105.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
N. D. Desai and G. T. Christakis
Stented Mechanical/Bioprosthetic Aortic Valve Replacement
Card. Surg. Adult, January 1, 2003; 2(2003): 825 - 856.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
F. Santini, G. B. Luciani, S. Restivo, G. Casali, R. Pessotto, P. Bertolini, A. Rossi, and A. Mazzucco
Over twenty-year follow-up of the standard Hancock porcine bioprosthesis implanted in the mitral position
Ann. Thorac. Surg., May 1, 2001; 71 (2007): S232 - S235.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. S. U. Myken, Håk. E. Berggren, S. Larsson, B. Roberts, I. Wallentin, and K. Caidahl
LONG-TERM DOPPLER ECHOCARDIOGRAPHIC RESULTS OF AORTIC OR MITRAL VALVE REPLACEMENT WITH BIOCOR PORCINE BIOPROSTHESIS
J. Thorac. Cardiovasc. Surg., October 1, 1998; 116(4): 599 - 608.
[Abstract] [Full Text] [PDF]


Home page
JWatch GeneralHome page
LONGER-LASTING BIOPROSTHETIC HEART VALVES
Journal Watch (General), September 30, 1994; 1994(930): 3 - 3.
[Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1994 by the American College of Cardiology Foundation.