Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1994; 24:254-259
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vazquez de Prada, J.
Right arrow Articles by Picard, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vazquez de Prada, J.
Right arrow Articles by Picard, M.

Quantification of pericardial effusions by three-dimensional echocardiography

JA Vazquez de Prada, L Jiang, MD Handschumacher, SW Xie, JM Rivera, E Schwammenthal, JL Guerrero, AE Weyman, RA Levine, and MH Picard

Cardiac Unit, Massachusetts General Hospital, Boston 02114.

OBJECTIVES. The purpose of this study was to examine the accuracy of three-dimensional echocardiography for the quantification of asymmetric pericardial effusion volume and to compare this new technique with two-dimensional echocardiography. BACKGROUND. Quantification of pericardial effusion by two-dimensional echocardiography relies on a symmetric distribution of the fluid. Three-dimensional echocardiography can quantitate volume without these limitations, but its accuracy for pericardial effusion volume has not yet been assessed. METHODS. In six open chest dogs, 41 different asymmetrically distributed pericardial effusions of known volume were created by serial infusions of fluid through a pericardial catheter. The hearts were imaged using an automated echocardiographic method that integrates three-dimensional spatial and imaging data. The surfaces of the pericardial sac and heart were then reconstructed, and the volumes of pericardial effusions were calculated. Two-dimensional echocardiography was performed simultaneously, and volumes were calculated using the prolate ellipsoid method. Asymmetric distribution of the fluid was obtained by applying localized hydrostatic pressure to the pericardium. RESULTS. The volumes of pericardial effusion quantified using three-dimensional echocardiography correlated well with actual volumes (y = 1.0x - 1.4, SEE = 7.7 ml, r = 0.98). Two-dimensional echocardiography had an acceptable correlation (y = 1.0x + 2.3, SEE = 23 ml, r = 0.84), but a marked degree of variation from the true value was observed for any individual measurement. CONCLUSIONS. Three-dimensional echocardiography accurately quantifies pericardial effusion volume in vivo, even when the fluid is distributed asymmetrically, whereas two-dimensional echocardiography is less reliable. This new technique may be of clinical value in quantitating pericardial effusion, especially in the serial evaluation of asymmetric or loculated effusions.


This article has been cited by other articles:


Home page
CirculationHome page
D. E. Gutstein, G. E. Morley, D. Vaidya, F. Liu, F. L. Chen, H. Stuhlmann, and G. I. Fishman
Heterogeneous Expression of Gap Junction Channels in the Heart Leads to Conduction Defects and Ventricular Dysfunction
Circulation, September 4, 2001; 104(10): 1194 - 1199.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
D. E. Gutstein, G. E. Morley, H. Tamaddon, D. Vaidya, M. D. Schneider, J. Chen, K. R. Chien, H. Stuhlmann, and G. I. Fishman
Conduction Slowing and Sudden Arrhythmic Death in Mice With Cardiac-Restricted Inactivation of Connexin43
Circ. Res., February 16, 2001; 88(3): 333 - 339.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. Gilon, E. G. Cape, M. D. Handschumacher, L. Jiang, C. Sears, J. Solheim, E. Morris, J. T. Strobel, S. M. Miller-Jones, A. E. Weyman, et al.
Insights From Three-dimensional Echocardiographic Laser Stereolithography: Effect of Leaflet Funnel Geometry on the Coefficient of Orifice Contraction, Pressure Loss, and the Gorlin Formula in Mitral Stenosis
Circulation, August 1, 1996; 94(3): 452 - 459.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement