Clinical outcome of patients with malignant ventricular tachyarrhythmias and a multiprogrammable implantable cardioverter-defibrillator implanted with or without thoracotomy: an international multicenter study. PCD Investigator Group
OBJECTIVES. The long-term efficacy and safety of a third-generation implantable cardioverter-defibrillator implanted with thoracotomy and nonthoracotomy lead systems was evaluated in a multicenter international study. BACKGROUND. The clinical impact of transvenous leads for nonthoracotomy implantation and pacing for bradyarrhythmias and tachyarrhythmias in implantable cardioverter-defibrillator systems is not well defined. METHODS. The safety of the implantation procedure and clinical outcome of 1,221 patients with symptomatic and life-threatening ventricular tachyarrhythmias who underwent implantation of a third-generation cardioverter-defibrillator using either a thoracotomy approach with epicardial leads (616 patients) or a nonthoracotomy approach with endocardial leads (605 patients) in a nonrandomized manner was analyzed. The implantable cardioverter-defibrillator system permitted pacing, cardioversion, defibrillation, arrhythmia event memory and noninvasive tachycardia induction. RESULTS. Successful implantation of an endocardial lead system was achieved in 605 (88.2%) of 686 patients and an epicardial system in 614 (99.7%) of 616 (p < 0.05). Perioperative 30-day mortality rate was 0.8% (1.8% including crossovers) in endocardial implant recipients compared with 4.2% (p < 0.001) in epicardial implant recipients (3.6% without crossovers, p < 0.05, respectively). Implantation mortality risk was significantly lower for nonthoracotomy systems irrespective of left ventricular ejection fraction or New York Heart Association functional class. Pacing therapies prevented need for cardioversion or defibrillation shocks in 89% of all ventricular tachycardia episodes and were comparably effective for both lead systems. Total survival rate at 2 years was significantly higher in endocardial (87.6%) than epicardial (81.9%) lead recipients (p < 0.001). Elimination of perioperative mortality from the analysis demonstrated comparable survival in both groups (p > 0.2). CONCLUSIONS. Third-generation cardioverter-defibrillators with monophasic waveforms can be successfully implanted with epicardial (99.7%) and endocardial (88.2%) lead systems. We conclude that endocardial leads should be the implant technique of first choice. Improved patient management and tolerance for device therapy is achieved with the addition of antitachycardia pacemaker capability in these systems.
This article has been cited by other articles:

|
 |

|
 |
 
B. Kupper, R. Yee, G. O'Hara, C. S. Simpson, P. D. Bella, M. Workel, M. Hull, and H. Heuer
Do small (6.6 Fr.) active and passive fixation defibrillation leads perform as well as larger sized leads? A multi-centre analysis
Europace,
August 1, 2007;
9(8):
657 - 661.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. K. Gehi, D. Mehta, and J. A. Gomes
Evaluation and Management of Patients After Implantable Cardioverter-Defibrillator Shock
JAMA,
December 20, 2006;
296(23):
2839 - 2847.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Saksena and N. Madan
Management of the Patient With an Implantable Cardioverter-Defibrillator in the Third Millennium
Circulation,
November 19, 2002;
106(21):
2642 - 2646.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
Committee Members, G. Gregoratos, J. Abrams, A. E. Epstein, R. A. Freedman, D. L. Hayes, M. A. Hlatky, R. E. Kerber, G. V. Naccarelli, M. H. Schoenfeld, et al.
ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices--Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
J. Am. Coll. Cardiol.,
November 6, 2002;
40(9):
1703 - 1719.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. Gregoratos, J. Abrams, A. E. Epstein, R. A. Freedman, D. L. Hayes, M. A. Hlatky, R. E. Kerber, G. V. Naccarelli, M. H. Schoenfeld, M. J. Silka, et al.
ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
Circulation,
October 15, 2002;
106(16):
2145 - 2161.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
G. D. Sanders, M. A. Hlatky, N. R. Every, K. M. McDonald, P. A. Heidenreich, L. S. Parsons, and D. K. Owens
Potential Cost-Effectiveness of Prophylactic Use of the Implantable Cardioverter Defibrillator or Amiodarone after Myocardial Infarction
Ann Intern Med,
November 20, 2001;
135(10):
870 - 883.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. H. Gollob and J. J. Seger
Current Status of the Implantable Cardioverter-Defibrillator
Chest,
April 1, 2001;
119(4):
1210 - 1221.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Saksena
Implantable defibrillators in the third millennium: increasingly relegated to a standby role?
J. Am. Coll. Cardiol.,
September 1, 2000;
36(3):
828 - 831.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Glatter and L. B. Liem
Implantable Cardioverter Defibrillator: Current Progress and Management
Seminars in Cardiothoracic and Vascular Anesthesia,
September 1, 2000;
4(3):
162 - 179.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
J P Bourke, R W F Campbell, J M McComb, S S Furniss, J C Doig, and C J Hilton
Surgery for postinfarction ventricular tachycardia in the pre-implantable cardioverter defibrillator era: early and long term outcomes in 100 consecutive patients
Heart,
August 1, 1999;
82(2):
156 - 162.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D. S. Cannom and E. N. Prystowsky
Management of Ventricular Arrhythmias: Detection, Drugs, and Devices
JAMA,
January 13, 1999;
281(2):
172 - 179.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C. Sticherling, A. Schaumann, T. Klingenheben, S. H. Hohnloser, and for the Ventak AV II DR investigators
First worldwide clinical experience with a new dual chamber implantable cardioverter defibrillator: Advantages and complications
Europace,
January 1, 1999;
1(2):
96 - 102.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
A.J. Solomon, J.B. Moubarak, J.M. Drood, C.M. Tracy, and P.E. Karasik
An abdominal active can defibrillator may facilitate a successful generator change when a lead failure is present
Europace,
January 1, 1999;
1(4):
266 - 269.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D. Bocker, D. Bansch, A. Heinecke, M. Weber, J. Brunn, D. Hammel, M. Borggrefe, G. Breithardt, and M. Block
Potential Benefit From Implantable Cardioverter-Defibrillator Therapy in Patients With and Without Heart Failure
Circulation,
October 20, 1998;
98(16):
1636 - 1643.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. J. Quan, J. H. Lee, O. Costantini, A. K. Konstantakos, H. K. Murrell, M. D. Carlson, J. A. Mackall, L. A. Biblo, and A. S. Geha
Favorable Results of Implantable Cardioverter-Defibrillator Implantation in Patients Older Than 70 Years
Ann. Thorac. Surg.,
December 1, 1997;
64(6):
1713 - 1717.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
W. G. Stevenson, P. L. Friedman, and M. O. Sweeney
Catheter Ablation as an Adjunct to ICD Therapy
Circulation,
September 2, 1997;
96(5):
1378 - 1380.
[Full Text]
|
 |
|

|
 |

|
 |
 
D. Bocker, W. Haverkamp, M. Block, M. Borggrefe, D. Hammel, and G. Breithardt
Comparison of d,l-Sotalol and Implantable Defibrillators for Treatment of Sustained Ventricular Tachycardia or Fibrillation in Patients With Coronary Artery Disease
Circulation,
July 15, 1996;
94(2):
151 - 157.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
J. Villacastin, J. Almendral, A. Arenal, J. Albertos, J. Ormaetxe, R. Peinado, H. Bueno, J. L. Merino, A. Pastor, O. Medina, et al.
Incidence and Clinical Significance of Multiple Consecutive, Appropriate, High-Energy Discharges in Patients With Implanted Cardioverter-Defibrillators
Circulation,
February 15, 1996;
93(4):
753 - 762.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
E. F.D. Wever, R. N.W. Hauer, G. Schrijvers, F. J.L. van Capelle, J. G.P. Tijssen, H. J.G.M. Crijns, A. Algra, H. Ramanna, P. F.A. Bakker, and E. O. Robles de Medina
Cost-effectiveness of Implantable Defibrillator as First-Choice Therapy Versus Electrophysiologically Guided, Tiered Strategy in Postinfarct Sudden Death Survivors : A Randomized Study
Circulation,
February 1, 1996;
93(3):
489 - 496.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
D. M. Shahian, W. A. Williamson, L. G. Svensson, R. S. D'Agostino, D. T. Martin, J. R. Ellis, and F. J. Venditti
Transvenous versus transthoracic cardioverter-defibrillator implantation: A comparative analysis of morbidity, mortality, and survival
J. Thorac. Cardiovasc. Surg.,
June 1, 1995;
109(6):
1066 - 1074.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
J. S. Lawton, K. A. Ellenbogen, M. A. Wood, B. S. Stambler, J. A. Spratt, A. S. Wechsler, and R. J. Damiano Jr
Clinical Experience With Nonthoracotomy Cardioverter Defibrillators
Ann. Thorac. Surg.,
May 1, 1995;
59(5):
1092 - 1098.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
J. McMurray and A. Rankin
Recent Advances: Cardiology II: Treatment of heart failure and atrial fibrillation and arrhythmias
BMJ,
December 17, 1994;
309(6969):
1631 - 1635.
[Full Text]
|
 |
|

|
 |

|
 |
 
DEFIBRILLATORS MAY BE SAFER IF IMPLANTED WITHOUT THORACOTOMY
Journal Watch (General),
June 17, 1994;
1994(617):
3 - 3.
[Full Text]
|
 |
|
|