Advertisement






Click here for more guidelines.
CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1994; 23:1342-1355
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Swerdlow, C.
Right arrow Articles by Peter, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Swerdlow, C.
Right arrow Articles by Peter, C.

Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillator

CD Swerdlow, PS Chen, RM Kass, Allard JR, and CT Peter

Division of Cardiology, Cedars-Sinai Medical Center, Los Angeles, California.

OBJECTIVES. This study was conducted to evaluate criteria for discrimination of ventricular tachycardia from atrial fibrillation and sinus tachycardia in a tiered-therapy cardioverter-defibrillator (Medtronic PCD). BACKGROUND. Interval stability algorithms discriminate ventricular tachycardia from atrial fibrillation. Onset algorithms discriminate ventricular tachycardia from sinus tachycardia. Neither has been validated clinically. METHODS. The stability criterion requires that a ventricular tachycardia interval not vary from any of the three previous intervals by more than the programmable stability value. The onset criterion detects initiation of ventricular tachycardia only if the ratio of an interval to the mean of four previous intervals is less than a programmed onset ratio and either the second or third preceding interval exceeds the ventricular tachycardia detection interval. We evaluated these criteria in 100 patients at electrophysiologic study and exercise testing (65 patients) and during a mean (+/- SD) follow-up of 16.2 +/- 7.9 months. The PCDs were programmed to tiered therapy in 54 patients. In the remaining 46 patients, the PCD's memory for detected ventricular tachycardia was used to study the specificity of the chosen onset criterion for rejecting sinus tachycardia. We used stored intervals preceding appropriate (n = 99) and inappropriate (n = 54) detections to test a new onset criterion that was less sensitive to a single index interval. RESULTS: Programmed stability of 40 ms decreased detection of induced atrial fibrillation by 95% (20 patients), paroxysmal atrial fibrillation by 95% (6 patients) and chronic atrial fibrillation by 99% (9 patients); all episodes of spontaneous (n = 877) and induced (n = 339) ventricular tachycardia were detected. A programmed onset ratio of 87% rejected sinus acceleration (98%) but caused underdetection of 0.5% of ventricular tachycardias. The onset criterion permitted inappropriate detection of premature ventricular complexes during sinus tachycardia, but the new criterion reduced these inappropriate detections by 98%. CONCLUSIONS. The PCD's onset and stability criteria reduced inappropriate detection of atrial fibrillation and sinus acceleration while detecting 99.5% of ventricular tachycardias.


This article has been cited by other articles:


Home page
EuropaceHome page
S. Tzeis, G. Andrikopoulos, C. Kolb, and P. E. Vardas
Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks
Europace, November 1, 2008; 10(11): 1256 - 1265.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
A. K. Gehi, D. Mehta, and J. A. Gomes
Evaluation and Management of Patients After Implantable Cardioverter-Defibrillator Shock
JAMA, December 20, 2006; 296(23): 2839 - 2847.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
R. Corbisiero, M. A. Lee, D. R. Nabert, J. A. Coman, D. J. Breiter, M. Schwartz, E. Mckittrick, and Y. Zhang
Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia based on vector timing and correlation
Europace, December 1, 2006; 8(12): 1057 - 1061.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Kadish and M. Mehra
Heart Failure Devices: Implantable Cardioverter-Defibrillators and Biventricular Pacing Therapy
Circulation, June 21, 2005; 111(24): 3327 - 3335.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. A.M.J. Theuns, A. P. J. Klootwijk, D. M. Goedhart, and L. J.L.M. Jordaens
Prevention of inappropriate therapy in implantable cardioverter-defibrillators: Results of a prospective, randomized study of tachyarrhythmia detection algorithms
J. Am. Coll. Cardiol., December 21, 2004; 44(12): 2362 - 2367.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. Bansch, F. Steffgen, G. Gronefeld, C. Wolpert, D. Bocker, R.-U. Mletzko, W. Schols, K. Seidl, M. Piel, F. Ouyang, et al.
The 1+1 Trial: A Prospective Trial of a Dual- Versus a Single-Chamber Implantable Defibrillator in Patients With Slow Ventricular Tachycardias
Circulation, August 31, 2004; 110(9): 1022 - 1029.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Vanhees, M. Kornaat, J. Defoor, G. Aufdemkampe, D. Schepers, A. Stevens, H. van Exel, J. van den Beld, H. Heidbuchel, and R. Fagard
Effect of exercise training in patients with an implantable cardioverter defibrillator
Eur. Heart J., July 1, 2004; 25(13): 1120 - 1126.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
E. Aliot, Rém. Nitzsché, and A. Ripart
Arrhythmia detection by dual-chamber implantable cardioverter defibrillators: A review of current algorithms
Europace, January 1, 2004; 6(4): 273 - 286.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
J. P. DiMarco
Implantable Cardioverter-Defibrillators
N. Engl. J. Med., November 6, 2003; 349(19): 1836 - 1847.
[Full Text] [PDF]


Home page
EuropaceHome page
J. L. Rojo-Alvarez, A. Arenal, A. Garcia-Alberola, M. Ortiz, M. Valdes, and A. Artes-Rodriguez
A new algorithm for rhythm discrimination in cardioverter defibrillators based on the initial voltage changes of the ventricular electrogram
Europace, January 1, 2003; 5(1): 77 - 82.
[Abstract] [PDF]


Home page
Eur Heart JHome page
R. Ricci, C. Pignalberi, M. Disertori, A. Capucci, L. Padeletti, G. Botto, S. Toscano, F. Miraglia, A. Grammatico, and M. Santini
Efficacy of a dual chamber defibrillator with atrial antitachycardia functions in treating spontaneous atrial tachyarrhythmias in patients with life-threatening ventricular tachyarrhythmias
Eur. Heart J., September 2, 2002; 23(18): 1471 - 1479.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. B. Schron, D. V. Exner, Q. Yao, L. S. Jenkins, J. S. Steinberg, J. R. Cook, S. P. Kutalek, P. L. Friedman, R. S. Bubien, R. L. Page, et al.
Quality of Life in the Antiarrhythmics Versus Implantable Defibrillators Trial: Impact of Therapy and Influence of Adverse Symptoms and Defibrillator Shocks
Circulation, February 5, 2002; 105(5): 589 - 594.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
R.N.W. Hauer, E. Aliot, M. Block, A. Capucci, B. Luderitz, M. Santini, and P.E. Vardas
Indications for implantable cardioverter defibrillator (ICD) therapy. Study Group on Guidelines on ICDs of the Working Group on Arrhythmias and the Working Group on Cardiac Pacing of the European Society of Cardiology
Eur. Heart J., July 1, 2001; 22(13): 1074 - 1081.
[PDF]


Home page
EuropaceHome page
R. N. W. Hauer, E. Aliot, M. Block, A. Capucci, B. Luderitz, M. Santini, and P. E. Vardas
Indications for implantable cardioverter defibrillator (ICD) therapy: Study Group on Guidelines on ICD of the Working Group on Arrhythmias and the Working Group on Cardiac Pacing of the European Society of Cardiology
Europace, January 1, 2001; 3(3): 169 - 176.
[PDF]


Home page
EuropaceHome page
D. Theuns, A. P. Klootwijk, G. P. Kimman, T. Szili-Torok, J. R. T. C. Roelandt, and L. Jordaens
Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators
Europace, January 1, 2001; 3(3): 181 - 186.
[Abstract] [PDF]


Home page
HeartHome page
R Tavernier, S Gevaert, J De Sutter, A De Clercq, H Rottiers, L Jordaens, and W Fonteyne
Long term results of cardioverter-defibrillator implantation in patients with right ventricular dysplasia and malignant ventricular tachyarrhythmias
Heart, January 1, 2001; 85(1): 53 - 56.
[Abstract] [Full Text]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
K. Glatter and L. B. Liem
Implantable Cardioverter Defibrillator: Current Progress and Management
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2000; 4(3): 162 - 179.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
D. Bansch, M. Castrucci, D. Bocker, G.u. Breithardt, and M. Block
Ventricular tachycardias above the initially programmed tachycardia detection interval in patients with implantable cardioverter-defibrillators: Incidence, prediction and significance
J. Am. Coll. Cardiol., August 1, 2000; 36(2): 557 - 565.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
T. Korte, W. Jung, G. Ostermann, C. Wolpert, S. Spehl, B. Esmailzadeh, and B. Luderitz
Hospital readmission after transvenous cardioverter/defibrillator implantation. A single centre study
Eur. Heart J., July 2, 2000; 21(14): 1186 - 1191.
[Abstract] [PDF]


Home page
EuropaceHome page
C. Sticherling, A. Schaumann, T. Klingenheben, S. H. Hohnloser, and for the Ventak AV II DR investigators
First worldwide clinical experience with a new dual chamber implantable cardioverter defibrillator: Advantages and complications
Europace, January 1, 1999; 1(2): 96 - 102.
[Abstract] [PDF]


Home page
CirculationHome page
M. Rosenqvist, T. Beyer, M. Block, K. den Dulk, J. Minten, and F. Lindemans
Adverse Events With Transvenous Implantable Cardioverter-Defibrillators : A Prospective Multicenter Study
Circulation, August 18, 1998; 98(7): 663 - 670.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Schaumann, F. v. z. Muhlen, B. Herse, B.-D. Gonska, and H. Kreuzer
Empirical Versus Tested Antitachycardia Pacing in Implantable Cardioverter Defibrillators : A Prospective Study Including 200 Patients
Circulation, January 13, 1998; 97(1): 66 - 74.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. D. Swerdlow, C. T. Peter, R. M. Kass, E. S. Gang, W. J. Mandel, C. Hwang, D. J. Martin, and P.-S. Chen
Programming of Implantable Cardioverter-Defibrillators on the Basis of the Upper Limit of Vulnerability
Circulation, March 18, 1997; 95(6): 1497 - 1504.
[Abstract] [Full Text]


Home page
CirculationHome page
M. Nair, N. Saoudi, D. Kroiss, and B. Letac
Automatic Arrhythmia Identification Using Analysis of the Atrioventricular Association: Application to a New Generation of Implantable Defibrillators
Circulation, February 18, 1997; 95(4): 967 - 973.
[Abstract] [Full Text]


Home page
CirculationHome page
R. W. Peters, S. McQuillan, S. K. Resnick, and M. R. Gold
Increased Monday Incidence of Life-Threatening Ventricular Arrhythmias: Experience With a Third-Generation Implantable Defibrillator
Circulation, September 15, 1996; 94(6): 1346 - 1349.
[Abstract] [Full Text]


Home page
CirculationHome page
G. J. Fahy, E. B. Sgarbossa, P. J. Tchou, and S. L. Pinski
Hospital Readmission in Patients Treated With Tiered-Therapy Implantable Defibrillators
Circulation, September 15, 1996; 94(6): 1350 - 1356.
[Abstract] [Full Text]


Home page
CirculationHome page
A. Garcia-Alberola, S. Yli-Mayry, M. Block, W. Haverkamp, A. Martinez-Rubio, H. Kottkamp, G. Breithardt, and M. Borggrefe
RR Interval Variability in Irregular Monomorphic Ventricular Tachycardia and Atrial Fibrillation
Circulation, January 15, 1996; 93(2): 295 - 300.
[Abstract] [Full Text]


Home page
CirculationHome page
S. L. Pinski and G. J. Fahy
The Proarrhythmic Potential of Implantable Cardioverter-Defibrillators
Circulation, September 15, 1995; 92(6): 1651 - 1664.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement