JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1994; 23:336-340
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yamashita, K
Right arrow Articles by Ohtomo, K
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yamashita, K
Right arrow Articles by Ohtomo, K

Radiofrequency thermal balloon coronary angioplasty: a new device for successful percutaneous transluminal coronary angioplasty

K Yamashita, S Satake, H Ohira, and K Ohtomo

Cardiovascular Department, Yokohama Red Cross Hospital, Japan.

OBJECTIVES. The purpose of this study was to evaluate the effects of thermal balloon percutaneous transluminal coronary angioplasty using radiofrequency energy in the treatment of patients with failed coronary angioplasty and complex lesions. In addition, we evaluated restenosis after radiofrequency thermal balloon applications. BACKGROUND. The efficacy of coronary angioplasty is limited by the relatively low success rate in complex lesions and the high frequency of restenosis. Few reports have studied the combined effects of pressure and laser thermal energy. This study describes a new device for coronary angioplasty using radiofrequency thermal energy. METHODS. Thirty-two patients with failed conventional coronary angioplasty or complex lesions were treated with radiofrequency thermal balloon coronary angioplasty. Radiofrequency energy was delivered up to 11 times in exposures ranging from 30 to 60 s in duration. This combined effect allowed the vascular wall to be heated to temperatures ranging from 60 to 70 degrees C. Follow-up coronary angiography was performed, on average, 6 months after the procedure. RESULTS. Successful radiofrequency coronary angioplasty was achieved in 28 (82%) of 34 lesions. There was one abrupt coronary artery occlusion (3%) and no death, perforation or dissection. Angiographic restenosis occurred in 14 (56%) of 25 lesions. CONCLUSIONS. In patients with failed coronary angioplasty and difficult complex lesions, radiofrequency coronary angioplasty could potentially improve angioplasty success rates and may have important implications for bailout cases with abrupt occlusion. However, restenosis remains a significant problem.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
K. Tanaka, S. Satake, S. Saito, S. Takahashi, Y. Hiroe, Y. Miyashita, S. Tanaka, M. Tanaka, and Y. Watanabe
A new radiofrequency thermal balloon catheter for pulmonary vein isolation
J. Am. Coll. Cardiol., December 1, 2001; 38(7): 2079 - 2086.
[Abstract] [Full Text] [PDF]