JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1994; 23:201-208
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rivera, J.
Right arrow Articles by Levine, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rivera, J.
Right arrow Articles by Levine, R.

Three-dimensional reconstruction of ventricular septal defects: validation studies and in vivo feasibility

JM Rivera, SC Siu, MD Handschumacher, JP Lethor, JL Guerrero, GJ Vlahakes, JD Mitchell, AE Weyman, ME King, and RA Levine

Noninvasive Cardiac Laboratory, Massachusetts General Hospital, Boston 02114.

OBJECTIVES. The purpose of this study was to demonstrate the feasibility of in vivo three-dimensional reconstruction of ventricular septal defects and to validate its quantitative accuracy for defect localization in excised hearts (used to permit comparison of three-dimensional and direct measurements without cardiac contraction). BACKGROUND. Appreciating the three-dimensional spatial relations of ventricular septal defects could be useful in planning surgical and catheter approaches. Currently, however, echocardiography provides only two-dimensional views, requiring mental integration. A recently developed system automatically combines two-dimensional echocardiographic images with their spatial locations to produce a three-dimensional construct. METHODS. Surgically created ventricular septal defects of varying size and location were imaged and reconstructed, along with the left and right ventricles, in the beating heart of six dogs to demonstrate the in vivo feasibility of producing a coherent image of the defect that portrays its relation to surrounding structures. Two additional gel-filled excised hearts with defects were completely reconstructed. Quantitative localization of the defects relative to other structures (ventricular apexes and valve insertions) was then validated for seven defects in excised hearts. The right septal margins of the exposed defects were also traced and compared with their reconstructed areas and circumferences. RESULTS. The three-dimensional images provided coherent images and correct spatial appreciation of the defects (two inlet, two trabecular, one outlet and one membranous Gerbode in vivo; one inlet and one apical in excised hearts). The distances between defects and other structures in the excised hearts agreed well with direct measures (y = 1.05x-0.18, r = 0.98, SEE = 0.30 cm), as did reconstructed areas (y = 1.0x-0.23, r = 0.98, SEE = 0.21 cm2) and circumferences (y = 0.97x + 0.13, r = 0.97, SEE = 0.3 cm). CONCLUSIONS. Three-dimensional reconstruction of ventricular septal defects can be achieved in the beating heart and provides an accurate appreciation of defect size and location that could be of value in planning interventions.


This article has been cited by other articles:


Home page
CirculationHome page
R. E. Kardon, Q. L. Cao, N. Masani, L. Sugeng, S. Supran, K. G. Warner, N. G. Pandian, and G. R. Marx
New Insights and Observations in Three-Dimensional Echocardiographic Visualization of Ventricular Septal Defects : Experimental and Clinical Studies
Circulation, September 29, 1998; 98(13): 1307 - 1314.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C. S. Breburda, B. P. Griffin, M. Pu, L. Rodriguez, D. M. Cosgrove III, and J. D. Thomas
Three-dimensional echocardiographic planimetry of maximal regurgitant orifice area in myxomatous mitral regurgitation: intraoperative comparison with proximal flow convergence
J. Am. Coll. Cardiol., August 1, 1998; 32(2): 432 - 437.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. Gilon, E. G. Cape, M. D. Handschumacher, L. Jiang, C. Sears, J. Solheim, E. Morris, J. T. Strobel, S. M. Miller-Jones, A. E. Weyman, et al.
Insights From Three-dimensional Echocardiographic Laser Stereolithography: Effect of Leaflet Funnel Geometry on the Coefficient of Orifice Contraction, Pressure Loss, and the Gorlin Formula in Mitral Stenosis
Circulation, August 1, 1996; 94(3): 452 - 459.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1994 by the American College of Cardiology Foundation.