JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1994; 23:123-132
© 1994 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stambler, B.
Right arrow Articles by Ellenbogen, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stambler, B.
Right arrow Articles by Ellenbogen, K.

Sensing/pacing lead complications with a newer generation implantable cardioverter-defibrillator: worldwide experience from the Guardian ATP 4210 clinical trial

BS Stambler, MA Wood, RJ Damiano, PS Greenway, ML Smutka, and KA Ellenbogen

Division of Cardiology and Cardiothoracic Surgery, Medical College of Virginia, Richmond 23249.

OBJECTIVES. This report describes the sensing/pacing lead complications that developed during a worldwide clinical trial of a new implantable cardioverter-defibrillator. BACKGROUND. The reliability of the leads used for sensing and pacing with the implantable cardioverter-defibrillator has not been adequately studied. METHODS. The Guardian ATP 4210 was implanted in 302 patients. The sensing/pacing leads consisted of either two unipolar epicardial electrodes or a bipolar endocardial electrode from a variety of manufacturers. RESULTS. During a mean follow-up period of 380 days, 39 patients (12.9%) required reoperation because their device developed sensing/pacing lead system complications. The most common clinical presentation was device oversensing (multiple tachycardia or noise detections or inappropriate shocks), which was observed in 27 patients, whereas elevated pacing thresholds were seen in 10 patients. Forty-one (11.8%) of 347 implanted lead systems required revision. The mean time to revision was 156 +/- 145 days. Actuarial lead survival rate at 1 and 3 years was 89% and 79%, respectively. Epicardial lead systems required significantly (p < 0.05) more revision than did endocardial systems, but when adapter problems were excluded, the revision rates of epicardial and endocardial leads were similar. Causes of lead system failures included adapter connection problems, lead dislodgement and insulation disruption. Predictors of lead revision were use of an epicardial lead system or an adapter. CONCLUSIONS. A high rate of sensing/pacing lead complications was found with this newer generation implantable cardioverter-defibrillator. The enhanced diagnostic and data storage capabilities of this implantable cardioverter-defibrillator facilitated the recognition and troubleshooting of these complications. These findings emphasize the need for careful surveillance and testing of implantable cardioverter-defibrillator sensing/pacing leads during follow-up.


This article has been cited by other articles:


Home page
EuropaceHome page
J. C. Senges-Becker, M. Klostermann, R. Becker, A. Bauer, K. E. Siegler, H. A. Katus, and W. Schoels
What is the "Optimal" follow-up schedule for ICD patients?
Europace, January 1, 2005; 7(4): 319 - 326.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
B. D. Gunderson, A. S. Patel, C. A. Bounds, R. K. Shepard, M. A. Wood, and K. A. Ellenbogen
An algorithm to predict implantable cardioverter-defibrillator lead failure
J. Am. Coll. Cardiol., November 2, 2004; 44(9): 1898 - 1902.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
K. A. Ellenbogen, M. A. Wood, R. K. Shepard, H. F. Clemo, T. Vaughn, K. Holloman, M. Dow, J. Leffler, A. Abeyratne, and D. Verness
Detection and management of animplantable cardioverter defibrillator lead failure: Incidence and clinical implications
J. Am. Coll. Cardiol., January 1, 2003; 41(1): 73 - 80.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
F. A. L. E. Bracke, A. Meijer, and L. M. van Gelder
Malfunction of endocardial defibrillator leads and lead extraction: where do they meet?
Europace, January 1, 2002; 4(1): 19 - 24.
[Full Text] [PDF]


Home page
CirculationHome page
A. Garcia-Alberola, S. Yli-Mayry, M. Block, W. Haverkamp, A. Martinez-Rubio, H. Kottkamp, G. Breithardt, and M. Borggrefe
RR Interval Variability in Irregular Monomorphic Ventricular Tachycardia and Atrial Fibrillation
Circulation, January 15, 1996; 93(2): 295 - 300.
[Abstract] [Full Text]


Home page
CirculationHome page
S. L. Pinski and G. J. Fahy
The Proarrhythmic Potential of Implantable Cardioverter-Defibrillators
Circulation, September 15, 1995; 92(6): 1651 - 1664.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
J. S. Lawton, K. A. Ellenbogen, M. A. Wood, B. S. Stambler, J. A. Spratt, A. S. Wechsler, and R. J. Damiano Jr
Clinical Experience With Nonthoracotomy Cardioverter Defibrillators
Ann. Thorac. Surg., May 1, 1995; 59(5): 1092 - 1098.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1994 by the American College of Cardiology Foundation.