JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1993; 22:1854-1857
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Varriale, P
Right arrow Articles by Chryssos, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Varriale, P
Right arrow Articles by Chryssos, B.

Atrial sensing performance of the single-lead VDD pacemaker during exercise

P Varriale and BE Chryssos

Department of Cardiology, Cabrini Medical Center, New York, New York 10003.

OBJECTIVES. The purpose of this study was to examine the atrial sensing performance of the single-lead VDD pacing system during exercise and concomitant changes in the amplitude of the atrial electrogram. BACKGROUND. Studies of conventional dual-chamber pacing have demonstrated an overall reduction in the atrial signal amplitude and a variable incidence of atrial undersensing during vigorous exercise. METHODS. The telemetered atrial electrogram and simultaneous surface electrocardiogram (ECG) were continuously recorded in 12 patients (mean age 70.8 years) with an implanted single-lead VDD pacing system during treadmill stress testing. The atrial signal amplitude was measured at peak exercise, and the patients were monitored for maintained atrial synchronized ventricular pacing during the entire exercise and recovery period. RESULTS. The atrial electrographic voltage decreased an average of 19.5% (p < 0.05) during peak exercise, and the reduced P wave amplitude ranged from 6.9% to 59.4% of the preexercise values in 8 of 12 patients. Three patients showed a modest increase in atrial signal amplitude, and one patient had no change. The telemetered electrogram displayed persistent and intact atrial synchronous ventricular pacing throughout the study period. CONCLUSIONS. Despite relatively low atrial signal amplitudes at rest and further decreases during exercise, the single-lead VDD pacemaker maintains reliable atrial tracking and ventricular pacing during vigorous exercise.


This article has been cited by other articles:


Home page
HeartHome page
P Hunziker, P Buser, M Pfisterer, F Burkart, and S Osswald
Predictors of loss of atrioventricular synchrony in single lead VDD pacing
Heart, October 1, 1998; 80(4): 390 - 392.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1993 by the American College of Cardiology Foundation.