Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1993; 22:1105-1110
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jenkins, K.
Right arrow Articles by Lock, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jenkins, K.
Right arrow Articles by Lock, J.

Multipolar endocardial mapping of the right atrium during cardiac catheterization: description of a new technique

KJ Jenkins, EP Walsh, SD Colan, DM Bergau, JP Saul, and JE Lock

Department of Cardiology, Children's Hospital, Boston, Massachusetts 02115.

OBJECTIVES. Using a new mapping system that allows the simultaneous acquisition of data from 25 right atrial bipolar electrodes during cardiac catheterization, we mapped normal sinus rhythm and atrial reentrant tachycardia in 24 sheep (20 to 49 kg) and 7 pigs (25 to 35 kg). BACKGROUND. Rapid, high resolution mapping during cardiac catheterization may shorten ablation procedures and permit ablation of otherwise refractory arrhythmias. METHODS. A flexible, elliptic, basket-shaped recording catheter has five spokes, each with 10 electrodes arranged as 5 bipolar pairs. Catheter shape, electrode spacing and introduction technique were modified in response to the results of experiments in the first 23 animals. In the most recent eight animals, retraction of a string attached to the distal tip distended the basket, providing safe tissue contact. Filtered (30 to 250 Hz) bipolar recordings from all 25 electrode pairs, as well as a surface electrocardiogram, were recorded and digitized at 1,000 Hz using custom software. An activation map was digitally constructed and superimposed on anteroposterior and lateral fluoroscopic catheter images. Bipolar recordings were made in normal sinus rhythm (31 animals), with adequate signals recorded from > 95% of electrode pairs. Rapid burst pacing and intentional right atrial air embolus (30 to 50 ml) induced sustained atrial reentrant tachycardia in five animals, which was also adequately recorded. RESULTS. Catheter positioning and complete atrial mapping required < 10 min after venous access in the most recent eight experiments. The catheter was left in position for up to 4 h. Postmortem evaluation revealed minor superficial abrasion of the venae cavae or right atrial endocardium in six animals and moderate abrasion in two. No other damage was observed. CONCLUSIONS. This new system may ultimately assist in mapping simple or complex atrial arrhythmias during cardiac catheterization.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
B. Zrenner, G. Ndrepepa, M. Schneider, M. Karch, F. Hofmann, A. Schomig, and C. Schmitt
Computer-assisted animation of atrial tachyarrhythmias recorded with a 64-electrode basket catheter
J. Am. Coll. Cardiol., December 1, 1999; 34(7): 2051 - 2060.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. Sun, E. O. Velipasaoglu, D. E. Wu, H. A. Kopelen, W. A. Zoghbi, W. H. Spencer III, and D. S. Khoury
Simultaneous Multisite Mapping of the Right and the Left Atrial Septum in the Canine Intact Beating Heart
Circulation, July 20, 1999; 100(3): 312 - 319.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
C. Schmitt, B. Zrenner, M. Schneider, M. Karch, G. Ndrepepa, I. Deisenhofer, S. Weyerbrock, J. Schreieck, and A. Schomig
Clinical Experience With a Novel Multielectrode Basket Catheter in Right Atrial Tachycardias
Circulation, May 11, 1999; 99(18): 2414 - 2422.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
F. H. M. Wittkampf, E. F. D. Wever, R. Derksen, A. A. M. Wilde, H. Ramanna, R. N. W. Hauer, and E. O. Robles de Medina
LocaLisa : New Technique for Real-Time 3-Dimensional Localization of Regular Intracardiac Electrodes
Circulation, March 16, 1999; 99(10): 1312 - 1317.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
B. T. Wyman, W. C. Hunter, F. W. Prinzen, and E. R. McVeigh
Mapping propagation of mechanical activation in the paced heart with MRI tagging
Am J Physiol Heart Circ Physiol, March 1, 1999; 276(3): H881 - H891.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. S. Khoury, K. L. Berrier, S. M. Badruddin, and W. A. Zoghbi
Three-Dimensional Electrophysiological Imaging of the Intact Canine Left Ventricle Using a Noncontact Multielectrode Cavitary Probe: Study of Sinus, Paced, and Spontaneous Premature Beats
Circulation, February 3, 1998; 97(4): 399 - 409.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Eldar, A. P. Fitzpatrick, D. Ohad, M. F. Smith, S. Hsu, J. G. Whayne, Z. Vered, Z. Rotstein, T. Kordis, D. K. Swanson, et al.
Percutaneous Multielectrode Endocardial Mapping During Ventricular Tachycardia in the Swine Model
Circulation, September 1, 1996; 94(5): 1125 - 1130.
[Abstract] [Full Text]


Home page
CirculationHome page
J. M. Kalman, R. J. Lee, W. G. Fisher, M. C. Chin, P. Ursell, C. A. Stillson, M. D. Lesh, and M. M. Scheinman
Radiofrequency Catheter Modification of Sinus Pacemaker Function Guided by Intracardiac Echocardiography
Circulation, November 15, 1995; 92(10): 3070 - 3081.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement