|
|
||||||||||
|
J Am Coll Cardiol, 1993; 22:1024-1032 © 1993 by the American College of Cardiology Foundation |
Cardiac Catheterization Laboratory, Washington Hospital Center, Washington, D.C. 20010.
OBJECTIVES. The purpose of this study was to use sequential intravascular ultrasound imaging before intervention, after rotational atherectomy and after adjunct balloon angioplasty to characterize the mechanisms of lumen enlargement after each. BACKGROUND. Rotational atherectomy uses a high speed, rotating, diamond-tipped elliptic burr to abrade atherosclerotic plaque to increase lumen size. In vitro studies have shown that high speed rotational atherectomy selectively abrades hard, especially calcified, plaque elements. However, rotational atherectomy procedures usually require adjunct balloon angioplasty. METHODS. Forty-eight lesions in 46 patients were treated with rotational atherectomy followed by adjunct balloon angioplasty in 44. Quantitative coronary arteriographic and intravascular ultrasound measurements of the target lesion were made before intervention, after rotational atherectomy and after balloon angioplasty. RESULTS. Before intervention, target lesion external elastic membrane area measured 17.3 +/- 5.9 mm2, lumen area measured 1.8 +/- 0.9 mm2 and plaque plus media area measured 15.7 +/- 4.1 mm2. After rotational atherectomy, lumen area increased, plaque plus media area decreased, arc of target lesion calcium decreased and 26% of the target lesions had dissection planes. After adjunct balloon angioplasty, external elastic membrane area increased, lumen area increased, plaque plus media area did not change and 77% of the target lesions had dissection planes. Arterial expansion was seen in 80% of lesions. The pattern of dissection plane location, which was predominantly within calcified plaque after rotational atherectomy, became predominantly adjacent to calcified plaque after adjunct balloon angioplasty (p = 0.008). CONCLUSIONS. Sequential intravascular ultrasound imaging shows that high speed rotational atherectomy causes lumen enlargement by selective ablation of hard, especially calcific, atherosclerotic plaque with little tissue disruption and rare arterial expansion. Adjunct balloon angioplasty further increased lumen area by a combination of arterial dissection and arterial expansion, especially of compliant, noncalcified plaque elements.
This article has been cited by other articles:
![]() |
J. L. Orford, A. Lerman, and D. R. Holmes Routine intravascular ultrasound guidance of percutaneous coronary intervention: A critical reappraisal J. Am. Coll. Cardiol., April 21, 2004; 43(8): 1335 - 1342. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Kwon, D. Choi, S.-H. Choi, Bon Kwon Koo, Y. Jang, W.-H. Shim, and S.-Y. Cho Coronary Stenting After Rotational Atherectomy in Diffuse Lesions of the Small Coronary Artery: Comparison with Balloon Angioplasty Before Stenting Angiology, July 1, 2003; 54(4): 423 - 431. [Abstract] [PDF] |
||||
![]() |
H. Okura, Y. Morino, A. Oshima, M. Hayase, M. R. Ward, J. J. Popma, R. E. Kuntz, H. N. Bonneau, P. G. Yock, and P. J. Fitzgerald Preintervention arterial remodeling affects clinical outcome following stenting: an intravascular ultrasound study J. Am. Coll. Cardiol., March 15, 2001; 37(4): 1031 - 1035. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. E. Nissen and P. Yock Intravascular Ultrasound : Novel Pathophysiological Insights and Current Clinical Applications Circulation, January 30, 2001; 103(4): 604 - 616. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Ahmed, G. S. Mintz, N. J. Weissman, A. J. Lansky, A. D. Pichard, L. F. Satler, and K. M. Kent Mechanism of Lumen Enlargement During Intracoronary Stent Implantation : An Intravascular Ultrasound Study Circulation, July 4, 2000; 102(1): 7 - 10. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Moussa, C. Di Mario, J. Moses, B. Reimers, L. Di Francesco, G. Martini, J. Tobis, and A. Colombo Coronary Stenting After Rotational Atherectomy in Calcified and Complex Lesions : Angiographic and Clinical Follow-Up Results Circulation, July 1, 1997; 96(1): 128 - 136. [Abstract] [Full Text] |
||||
![]() |
G. S. Mintz, K. M. Kent, A. D. Pichard, L. F. Satler, J. J. Popma, and M. B. Leon Contribution of Inadequate Arterial Remodeling to the Development of Focal Coronary Artery Stenoses : An Intravascular Ultrasound Study Circulation, April 1, 1997; 95(7): 1791 - 1798. [Abstract] [Full Text] |
||||
![]() |
G. S. Mintz, J. J. Popma, A. D. Pichard, K. M. Kent, L. F. Satler, S. Chiu Wong, M. K. Hong, J. A. Kovach, and M. B. Leon Arterial Remodeling After Coronary Angioplasty : A Serial Intravascular Ultrasound Study Circulation, July 1, 1996; 94(1): 35 - 43. [Abstract] [Full Text] |
||||
![]() |
G. S. Mintz, J. J. Popma, A. D. Pichard, K. M. Kent, L. F. Satler, Y. Chien Chuang, R. A. DeFalco, and M. B. Leon Limitations of Angiography in the Assessment of Plaque Distribution in Coronary Artery Disease : A Systematic Study of Target Lesion Eccentricity in 1446 Lesions Circulation, March 1, 1996; 93(5): 924 - 931. [Abstract] [Full Text] |
||||
![]() |
G. S. Mintz, J. A. Kovach, S. P. Javier, A. D. Pichard, K. M. Kent, J. J. Popma, L. F. Salter, and M. B. Leon Mechanisms of Lumen Enlargement After Excimer Laser Coronary Angioplasty : An Intravascular Ultrasound Study Circulation, December 15, 1995; 92(12): 3408 - 3414. [Abstract] [Full Text] |
||||
![]() |
G. S. Mintz, J. J. Popma, A. D. Pichard, K. M. Kent, L. F. Satler, Y. C. Chuang, C. J. Ditrano, and M. B. Leon Patterns of Calcification in Coronary Artery Disease : A Statistical Analysis of Intravascular Ultrasound and Coronary Angiography in 1155 Lesions Circulation, April 1, 1995; 91(7): 1959 - 1965. [Abstract] [Full Text] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |