Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1993; 22:899-906
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Marsch, S.
Right arrow Articles by Foex, P
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marsch, S.
Right arrow Articles by Foex, P

Graded myocardial ischemia is associated with a decrease in diastolic distensibility of the remote nonischemic myocardium in the anesthetized dog

SC Marsch, VA Wanigasekera, WA Ryder, LS Wong, and P Foex

Nuffield Department of Anesthetics, University of Oxford, Radcliffe Infirmary, England, United Kingdom.

OBJECTIVES. This study was designed to investigate the changes in regional distensibility of the ischemic segment and of a remote nonischemic segment brought about by graded myocardial ischemia. BACKGROUND. Ventricular distensibility is a major determinant of left ventricular end-diastolic pressure. The effects of graded myocardial ischemia on the regional distensibility of the ischemic area have not been studied. Moreover, there are few data on the effects of myocardial ischemia on the regional distensibility of the nonischemic myocardium. METHODS. Nine anesthetized open chest mongrel dogs were fitted with instruments to measure left ventricular pressure and circumferential length (sonomicrometry) in the ischemic segment and in a nonischemic segment. The pressure-length relation was modified by stepwise infusion and withdrawal of 200 ml of each dog's own blood over 30 min in five consecutive stages of regional ischemia. Unstressed dimensions were obtained by repeated inferior vena cava occlusions. In both segments, regional distensibility was assessed at end-diastole by means of the constants of the pressure-length (chamber stiffness), the pressure-strain and the force-strain (myocardial stiffness) relations. RESULTS. In the ischemic segment, partial and complete coronary occlusions were associated with a twofold increase in the chamber stiffness constant, the pressure-strain constant and the myocardial stiffness constant, whereas in the nonischemic segment the chamber stiffness constant, the pressure-strain constant and the myocardial stiffness constant increased by 50%. CONCLUSIONS. Regional myocardial ischemia is associated with a decrease in distensibility of both the ischemic and the remote nonischemic myocardium.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. N. Mazzadi, X. Andre-Fouet, N. Costes, P. Croisille, D. Revel, and M. F. Janier
Mechanisms leading to reversible mechanical dysfunction in severe CAD: alternatives to myocardial stunning
Am J Physiol Heart Circ Physiol, December 1, 2006; 291(6): H2570 - H2582.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
M. Zaugg, M. C. Schaub, and P. Foex
Myocardial injury and its prevention in the perioperative setting
Br. J. Anaesth., July 1, 2004; 93(1): 21 - 33.
[Abstract] [Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement