Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1993; 22:746-750
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Callans, D.
Right arrow Articles by Marchlinski, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Callans, D.
Right arrow Articles by Marchlinski, F.

Effect of rate and coupling interval on endocardial R wave amplitude variability in permanent ventricular sensing lead systems

DJ Callans, BG Hook, and FE Marchlinski

Clinical Electrophysiology Laboratory, Hospital of the University of Pennsylvania, Philadelphia 19104.

OBJECTIVES. We have observed sensing errors in third generation implantable cardioverter-defibrillators that appear to be caused by variation in the R wave amplitude during sinus rhythm, particularly after premature beats. The purpose of this study was to quantify spontaneous R wave variability during sinus rhythm and to determine whether abrupt changes in cycle length further augment R wave amplitude variability. BACKGROUND: Pacemaker sensing algorithms presume a relatively constant R wave signal to establish a sensing threshold. The concept of a fixed sensing threshold is not as applicable in third-generation cardioverter-defibrillators, which depend on automatic gain amplifiers to rapidly detect ventricular fibrillation. These devices may be susceptible to undersensing during sinus rhythm if significant variability in R wave signal characteristics occurs. METHODS. Twelve patients with combination bradycardia pacing cardioverter-defibrillators were studied. The device used (Cadence, Ventritex) allowed recording of real time, telemetered electrograms from the sensing lead system. Measurements were made of the maximal range of the R wave amplitude during sinus rhythm and in response to abrupt changes in heart rate produced by premature atrial and ventricular stimuli. RESULTS: The maximal range in R wave amplitude during sinus rhythm was 1.7 +/- 1.3 mV, or 23.7 +/- 19.2% of the mean R wave amplitude. The R wave amplitude variability increased with abrupt changes in cycle length, with a range of 2.8 +/- 1.5 mV, or 38.8 +/- 18.3% of the mean R wave amplitude (p < 0.05 compared with sinus rhythm). In most patients, R wave amplitude and coupling interval demonstrated an inverse proportional relation. CONCLUSIONS. There is substantial variability in the R wave amplitude during sinus rhythm measured by permanent ventricular sensing lead systems, and this variability is further augmented by abrupt changes in cycle length. This phenomenon may explain the occurrence of undersensing of sinus rhythm in implantable cardioverter-defibrillators with automatic gain sense amplifiers.


This article has been cited by other articles:


Home page
ANN INTERN MEDHome page
S. Nazarian, R. Hansford, A. Roguin, D. Goldsher, M. M. Zviman, A. C. Lardo, B. S. Caffo, K. D. Frick, M. A. Kraut, I. R. Kamel, et al.
A Prospective Evaluation of a Protocol for Magnetic Resonance Imaging of Patients With Implanted Cardiac Devices
Ann Intern Med, October 4, 2011; 155(7): 415 - 424.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. L. Pinski and G. J. Fahy
The Proarrhythmic Potential of Implantable Cardioverter-Defibrillators
Circulation, September 15, 1995; 92(6): 1651 - 1664.
[Abstract] [Full Text]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement