Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1993; 22:727-732
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Isshiki, T
Right arrow Articles by Suma, H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Isshiki, T
Right arrow Articles by Suma, H

Percutaneous angioplasty of stenosed gastroepiploic artery grafts

T Isshiki, T Yamaguchi, T Tamura, F Saeki, Y Furuta, Y Ikari, N Chiku, and H Suma

Division of Cardiology, Mitsui Memorial Hospital, Tokyo, Japan.

OBJECTIVES. This report describes our early experience and results with percutaneous transluminal coronary angioplasty of gastroepiploic artery grafts in 12 patients. BACKGROUND. Angioplasty has been successfully performed in saphenous vein and internal thoracic artery grafts; however, experience with angioplasty in gastroepiploic artery/coronary artery bypass grafts is limited. METHODS. Balloon angioplasty was performed in 12 patients (11 men, 1 woman; mean age 58 +/- 8 years) with either total occlusion (6 patients) or severe stenosis (6 patients) of a gastroepiploic artery/coronary artery anastomosis. In seven patients, a guide wire/balloon catheter system was used through a 7F sheath inserted into the celiac trunk. In seven patients, including two who had unsuccessful wire/balloon angioplasty, an over the wire system was used through a 6.5F Cobra or 7F JR4 guide catheter, selectively inserted into the gastroduodenal artery. RESULTS. Angioplasty was successful in five (83%) of six patients with stenosis and in one of six patients with total occlusion (p = 0.08, 1 - beta = 0.68). The guide wire could not be advanced through the lesion in five patients, and the balloon catheter did not cross the lesion in one patient whose gastroepiploic artery was tortuous. Catheters exhibited better trackability and pushability when the over the wire system was used, and five of the six successes were achieved using this approach. Follow-up arteriography was performed in five patients, and all of the gastroepiploic artery grafts were patent without stenosis. CONCLUSIONS. Angioplasty can be safely performed in stenosed gastroepiploic artery grafts. An over the wire system that uses a thin balloon catheter inserted through a guide catheter in the gastroduodenal artery seems optimal.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
S. C. Smith Jr, J. T. Dove, A. K. Jacobs, J. Ward Kennedy, D. Kereiakes, M. J. Kern, R. E. Kuntz, J. J. Popma, H. V. Schaff, D. O. Williams, et al.
ACC/AHA guidelines for percutaneous coronary intervention (revision of the 1993 PTCA guidelines): A report of the American College of Cardiology/ American Heart Association Task Force on practice guidelines (Committee to revise the 1993 guidelines for percutaneous transluminal coronary angioplasty) endorsed by the Society for Cardiac Angiography and Interventions
J. Am. Coll. Cardiol., June 15, 2001; 37(8): 2239 - 2239.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. D. Fonger, J. R. Doty, J. D. Salazar, P. L. Walinsky, and N. W. Salomon
Initial experience with MIDCAB grafting using the gastroepiploic artery
Ann. Thorac. Surg., August 1, 1999; 68(2): 431 - 436.
[Abstract] [Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement