Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1993; 22:550-556
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bashir, Y
Right arrow Articles by Ward, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bashir, Y
Right arrow Articles by Ward, D.

Radiofrequency current delivery by way of a bipolar tricuspid annulus-mitral annulus electrode configuration for ablation of posteroseptal accessory pathways

Y Bashir, SC Heald, S O'Nunain, D Katritsis, AJ Camm, and DE Ward

Department of Cardiological Sciences, Saint George's Hospital Medical School, London, England, United Kingdom.

OBJECTIVES. This report describes a novel technique for ablation of "difficult" posteroseptal pathways. BACKGROUND. Although radiofrequency ablation of accessory atrioventricular (AV) pathways is successful in > or = 90% of cases, particular difficulty may be encountered with some bypass tracts in the posteroseptal region. METHODS. In eight patients with posteroseptal accessory pathways (two concealed), radiofrequency catheter ablation using conventional unipolar current applications from favorable sites along the tricuspid or mitral annulus, or both, was unsuccessful. Subsequently, a bipolar technique was adopted, with current application between the distal electrodes of two catheters positioned against the septal region at sites of early activation along both mitral and tricuspid annuli. RESULTS. The bipolar configuration proved effective in all cases. The number of bipolar lesions required for success was one (five patients), five (two patients) and nine (one patient). In five patients, bipolar current application abolished pathway conduction using positions at which delivery of unipolar lesions had been ineffective or caused transient block. The AV or ventriculoatrial interval at successful sites varied from 20 to 65 ms, and the time from delta wave onset to local ventricular activation was zero or negative. There were no complications attributable to the bipolar technique. During follow-up of 8 to 36 weeks, pathway conduction has not recurred in any patient. CONCLUSIONS. Bipolar radiofrequency current delivery across the septal region using a tricuspid annulus-mitral annulus electrode configuration may abolish accessory pathway conduction when conventional unipolar applications have proved ineffective. The technique may reduce procedure duration, radiation exposure and overall failure rate in these problematic cases.




 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement