JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1993; 22:119-126
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by De Bruyne, B
Right arrow Articles by Heyndrickx, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by De Bruyne, B
Right arrow Articles by Heyndrickx, G.

Transstenotic coronary pressure gradient measurement in humans: in vitro and in vivo evaluation of a new pressure monitoring angioplasty guide wire

B De Bruyne, NH Pijls, WJ Paulus, PJ Vantrimpont, SU Sys, and GR Heyndrickx

Cardiovascular Center, Aalst, Belgium.

OBJECTIVES. The present study was designed to investigate 1) the feasibility and accuracy of coronary pressure measurements with a novel 0.015-in. (0.038 cm) fluid-filled guide wire, and 2) the effect of the guide wire itself on stenosis hemodynamics. BACKGROUND. To assess the functional results of coronary angioplasty, measurements of the transstenotic pressure gradient have been advocated. However, this gradient is no longer routinely measured because it is not reliable when determined with the angioplasty catheter. METHODS. A fluid-filled 0.015-in. guide wire to be connected to a conventional pressure transducer was developed. Five wires were tested for their frequency response characteristics and for their accuracy in measuring hydrostatic pressure. In an in vitro model of stenosis (reference diameter 4 mm), the pressure gradient was determined at incremental flow levels for varying stenosis severity with and without a 0.015-in. guide wire through the narrowing. In 37 patients, the transstenotic pressure gradient was measured before and after angioplasty and compared with obstruction area and percent area stenosis as determined by quantitative coronary angiography. RESULTS. The correlation between the actual pressure and the pressure recorded by the guide wire was excellent (r = 0.98) despite a slight underestimation (-3 +/- 5%). Phasic pressure recordings were precluded by a long time constant of 16 +/- 4 s. The presence of the guide wire produced a significant overestimation (> 20%) of the pressure decrease only in cases of tight stenosis (> 90% area reduction). Furthermore, a theoretic model based on the fluid dynamic equation predicted that this overestimation was inversely proportional to the reference diameter of the vessel, yet was only slightly influenced by the flow. The lesion was crossed in all but one patient (97%) and pressure gradient was recorded throughout the study in 34 (94%) of 36 patients. The mean pressure gradient decreased from 30 +/- 19 before to 3 +/- 5 mm Hg after angioplasty (p < 0.01). A curvilinear relation was found between the pressure gradient and both percent area stenosis (r2 = 0.67) and obstruction area (r2 = 0.72). A sharp increase in pressure gradient was noted once the stenosis exceeded 75% area reduction. CONCLUSIONS. Mean transstenotic pressure gradients can be easily and reliably recorded with a 0.015-in. fluid-filled guide wire. This ability should facilitate the functional assessment of coronary stenoses of intermediate severity and of immediate postangioplasty results.


This article has been cited by other articles:


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
H. J. Verberne, M. Meuwissen, S. A. J. Chamuleau, B.-J. Verhoeff, B. L. F. van Eck-Smit, J. A. E. Spaan, J. J. Piek, and M. Siebes
Effect of simultaneous intracoronary guidewires on the predictive accuracy of functional parameters of coronary lesion severity
Am J Physiol Heart Circ Physiol, May 1, 2007; 292(5): H2349 - H2355.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
P. Legalery, F. Schiele, M.-F. Seronde, N. Meneveau, H. Wei, K. Didier, M.-C. Blonde, F. Caulfield, and J.-P. Bassand
One-year outcome of patients submitted to routine fractional flow reserve assessment to determine the need for angioplasty
Eur. Heart J., December 2, 2005; 26(24): 2623 - 2629.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
A. S. Roy, R. K. Banerjee, L. H. Back, M. R. Back, S. Khoury, and R. W. Millard
Delineating the guide-wire flow obstruction effect in assessment of fractional flow reserve and coronary flow reserve measurements
Am J Physiol Heart Circ Physiol, July 1, 2005; 289(1): H392 - H397.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
W. K. Hau
Fractional flow reserve and complex coronary pathologic conditions
Eur. Heart J., May 1, 2004; 25(9): 723 - 727.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
T. Bupha-Intr and J. Wattanapermpool
Cardioprotective effects of exercise training on myofilament calcium activation in ovariectomized rats
J Appl Physiol, May 1, 2004; 96(5): 1755 - 1760.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. I. E. Hoffman
Do we have agold standard yet?
J. Am. Coll. Cardiol., February 18, 2004; 43(4): 662 - 664.
[Full Text] [PDF]


Home page
JAMAHome page
S. S. Rathore, J. P. Curtis, Y. Wang, M. R. Bristow, and H. M. Krumholz
Association of Serum Digoxin Concentration and Outcomes in Patients With Heart Failure
JAMA, February 19, 2003; 289(7): 871 - 878.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Siebes, S. A. J. Chamuleau, M. Meuwissen, J. J. Piek, and J. A. E. Spaan
Influence of hemodynamic conditions on fractional flow reserve: parametric analysis of underlying model
Am J Physiol Heart Circ Physiol, October 1, 2002; 283(4): H1462 - H1470.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. Brosh, S. T. Higano, M. J. Slepian, H. I. Miller, M. J. Kern, R. J. Lennon, D. R. Holmes Jr, and A. Lerman
Pulse transmission coefficient: a novel nonhyperemic parameter for assessing the physiological significance of coronary artery stenoses
J. Am. Coll. Cardiol., March 20, 2002; 39(6): 1012 - 1019.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Abe, H. Tomiyama, H. Yoshida, and N. Doba
Diastolic Fractional Flow Reserve to Assess the Functional Severity of Moderate Coronary Artery Stenoses : Comparison With Fractional Flow Reserve and Coronary Flow Velocity Reserve
Circulation, November 7, 2000; 102(19): 2365 - 2370.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
B. De Bruyne, N. H. J. Pijls, G. R. Heyndrickx, D. Hodeige, R. Kirkeeide, and K. L. Gould
Pressure-Derived Fractional Flow Reserve to Assess Serial Epicardial Stenoses : Theoretical Basis and Animal Validation
Circulation, April 18, 2000; 101(15): 1840 - 1847.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. J. Kern
Coronary Physiology Revisited : Practical Insights From the Cardiac Catheterization Laboratory
Circulation, March 21, 2000; 101(11): 1344 - 1351.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J.J Piek, E Boersma, C di Mario, E Schroeder, C Vrints, P Probst, B de Bruyne, C Hanet, E Fleck, M Haude, et al.
Angiographical and Doppler flow-derived parameters for assessment of coronary lesion severity and its relation to the result of exercise electrocardiography
Eur. Heart J., March 2, 2000; 21(6): 466 - 474.
[Abstract] [PDF]


Home page
CirculationHome page
A. Jeremias, S. D. Filardo, R. J. Whitbourn, R. S. Kernoff, A. C. Yeung, P. J. Fitzgerald, and P. G. Yock
Effects of Intravenous and Intracoronary Adenosine 5'-Triphosphate as Compared With Adenosine on Coronary Flow and Pressure Dynamics
Circulation, January 25, 2000; 101(3): 318 - 323.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
M POULLIS
Coronary pressure measurements: catheter induced errors
Heart, November 1, 1999; 82(5): 644a - 645.
[Full Text]


Home page
CirculationHome page
J. Bartunek, W. Wijns, G. R. Heyndrickx, and B. de Bruyne
Effects of Dobutamine on Coronary Stenosis Physiology and Morphology : Comparison With Intracoronary Adenosine
Circulation, July 20, 1999; 100(3): 243 - 249.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. S. Abizaid, G. S. Mintz, R. Mehran, A. Abizaid, A. J. Lansky, A. D. Pichard, L. F. Satler, H. Wu, C. Pappas, K. M. Kent, et al.
Long-Term Follow-Up After Percutaneous Transluminal Coronary Angioplasty Was Not Performed Based on Intravascular Ultrasound Findings : Importance of Lumen Dimensions
Circulation, July 20, 1999; 100(3): 256 - 261.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. J. Scanlon, D. P. Faxon, A.-M. Audet, B. Carabello, G. J. Dehmer, K. A. Eagle, R. D. Legako, D. F. Leon, J. A. Murray, S. E. Nissen, et al.
ACC/AHA guidelines for coronary angiography: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Coronary Angiography) developed in collaboration with the Society for Cardiac Angiography and Interventions
J. Am. Coll. Cardiol., May 1, 1999; 33(6): 1756 - 1824.
[Full Text] [PDF]


Home page
ANGIOLOGYHome page
M. Isobe, H. Takenaka, O. Kinoshita, M. Sekiguchi, M. Ohta, and H. Imamura
Successful Stenting of Bilateral Renal Artery Stenosis Due to Fibromuscular Dysplasia Assessed by Use of Pressure Guidewire Technique: A Case Report
Angiology, January 1, 1998; 49(1): 69 - 74.
[Abstract] [PDF]


Home page
CirculationHome page
B. de Bruyne, J. Bartunek, S. U. Sys, N. H.J. Pijls, G. R. Heyndrickx, and W. Wijns
Simultaneous Coronary Pressure and Flow Velocity Measurements in Humans: Feasibility, Reproducibility, and Hemodynamic Dependence of Coronary Flow Velocity Reserve, Hyperemic Flow Versus Pressure Slope Index, and Fractional Flow Reserve
Circulation, October 15, 1996; 94(8): 1842 - 1849.
[Abstract] [Full Text]


Home page
CirculationHome page
N. H.J. Pijls, B. Van Gelder, P. Van der Voort, K. Peels, F. A.L.E. Bracke, H. J.R.M. Bonnier, and M. I.H. El Gamal
Fractional Flow Reserve : A Useful Index to Evaluate the Influence of an Epicardial Coronary Stenosis on Myocardial Blood Flow
Circulation, December 1, 1995; 92(11): 3183 - 3193.
[Abstract] [Full Text]


Home page
CirculationHome page
B. De Bruyne, J. Bartunek, S. U. Sys, and G. R. Heyndrickx
Relation Between Myocardial Fractional Flow Reserve Calculated From Coronary Pressure Measurements and Exercise-Induced Myocardial Ischemia
Circulation, July 1, 1995; 92(1): 39 - 46.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1993 by the American College of Cardiology Foundation.