cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1993; 21:1413-1418
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Newman, D
Right arrow Articles by Hardy, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Newman, D
Right arrow Articles by Hardy, J

Randomized controlled comparison of antitachycardia pacing algorithms for termination of ventricular tachycardia

D Newman, P Dorian, and J Hardy

Division of Cardiology, St. Michael's Hospital, Toronto, Ontario, Canada.

OBJECTIVES. This study compared the efficacy and safety of two antitachycardia pacing algorithms in the treatment of ventricular tachycardia. BACKGROUND. There is agreement that antitachycardia pacing should be adapted to tachycardia rate and be delivered in a burst, but the ideal pacing pattern is not well understood. Effective antitachycardia pacing burst patterns include those with a between-burst decrement (SCAN) with or without an additional within-burst decrement (RAMP). METHODS. Prospective randomized crossover comparison of two antitachycardia pacing algorithms (RAMP vs. SCAN) on identical induced sustained ventricular tachycardias was performed. RESULTS. Sixty-five ventricular tachycardias (mean cycle length 364 +/- 74 ms) from 37 invasive studies performed in 29 patients were studied; 86% of patients had coronary artery disease and 72% were receiving antiarrhythmic therapy at the time of study. Of the 65 tachycardias, 40 were identical pairs and 25 were unpaired (including 8 with a > 30-ms difference in cycle length of induced ventricular tachycardia pairs). In the paired pacing trials, conversion to sinus rhythm occurred, respectively, in 85% of SCAN versus 90% of RAMP protocols (p = 0.63, power = 93%) and within 1.4 +/- 0.7 versus 1.7 +/- 1.1 attempts (p = 0.41). Discordance for pacing success was seen in three pairs. In unpaired trials, conversion to sinus rhythm occurred in 73% and 57%, respectively (p = 0.68, power = 88%). Tachycardia acceleration during pacing occurred in 7 (11%) of 65 attempts (5 SCAN, 2 RAMP). Acceleration in unpaired ventricular tachycardia trials was correlated with tachycardia cycle length. Failure to convert ventricular tachycardia was associated with a shorter tachycardia cycle length (p < 0.05). CONCLUSIONS. In the patients studied, adaptive antitachycardia pacing was safe and effective and, when successful, occurred within three attempts of an 8-beat adaptive burst algorithm. Changes in burst pattern did not affect pacing safety or efficacy. Antitachycardia pacing success was dependent on induced ventricular tachycardia cycle length.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
J. Jimenez-Candil, A. Arenal, A. Garcia-Alberola, M. Ortiz, S. d. Castillo, J. Fernandez-Portales, J. Sanchez-Munoz, J. Martinez-Sanchez, E. Gonzalez-Torrecilla, F. Atienza, et al.
Fast ventricular tachycardias in patients with implantable cardioverter-defibrillators: Efficacy and safety of antitachycardia pacing: A prospective and randomized study
J. Am. Coll. Cardiol., February 1, 2005; 45(3): 460 - 461.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. Ruppel, C. A. Schluter, S. Boczor, T. Meinertz, M. Schluter, K.-H. Kuck, and R. Cappato
Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: experience from stored electrograms of implantable cardioverter-defibrillators
J. Am. Coll. Cardiol., November 15, 1998; 32(6): 1724 - 1730.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. L. Pinski and G. J. Fahy
The Proarrhythmic Potential of Implantable Cardioverter-Defibrillators
Circulation, September 15, 1995; 92(6): 1651 - 1664.
[Abstract] [Full Text]


Home page
CirculationHome page
M. H. Raitt, G. L. Dolack, P. J. Kudenchuk, J. E. Poole, and G. H. Bardy
Ventricular Arrhythmias Detected After Transvenous Defibrillator Implantation in Patients With a Clinical History of Only Ventricular Fibrillation : Implications for Use of Implantable Defibrillator
Circulation, April 1, 1995; 91(7): 1996 - 2001.
[Abstract] [Full Text]



 
  cardiology careers collections past issues search home