Digital supine bicycle stress echocardiography: a new technique for evaluating coronary artery disease
HS Hecht,
L DeBord,
R Shaw,
R Dunlap,
C Ryan,
SH Stertzer,
and
RK Myler
San Francisco Heart Institute, Seton Medical Center, Daly City, California 94015.
OBJECTIVES. The objective of this study was to determine the accuracy of digital supine bicycle stress echocardiography, a new technique for evaluating coronary artery disease during peak exercise. BACKGROUND. Prior stress echocardiographic techniques have not utilized peak exercise imaging to determine the extent and location of coronary artery disease. METHODS. Two-hundred twenty-two patients were studied: 180 underwent both supine bicycle stress echocardiography and coronary arteriography; 42 had a < 5% likelihood of disease. Forty-three patients had normal coronary arteries, 55 had single-vessel, 42 had double-vessel and 40 had triple-vessel coronary artery disease. RESULTS. Supine bicycle stress echocardiography was 93% sensitive, 86% specific and 92% accurate for identifying patients with coronary artery disease irrespective of prior myocardial infarction or achievement of > or = 85% maximal predicted heart rate. The "normalcy" rate in the low probability group was 100%. Supine bicycle stress echocardiography was 87% sensitive, 89% specific and 88% accurate for specific vessel identification. The sensitivity was greatest for the left anterior descending compared with the right coronary artery and the left circumflex coronary artery (95% vs. 81% vs. 78%, p < 0.01) and for vessels in patients with double- and triple-vessel compared with single-vessel disease (90% vs. 89% vs. 78%, p < 0.05). The procedure was significantly more sensitive for detection of vessels with 90% to 100% compared with 50% to 70% diameter stenosis (91% vs. 81%, p < 0.05) and was 88% correct in the prediction of multivessel disease. CONCLUSIONS. Supine bicycle stress echocardiography is a highly accurate tool for evaluating coronary artery disease, identifying both the patient with coronary artery disease and the location and extent of disease.
This article has been cited by other articles:

|
 |

|
 |
 
T.-H. Park, N. Tayan, K. Takeda, H.-K. Jeon, M. A. Quinones, and W. A. Zoghbi
Supine Bicycle Echocardiography: Improved Diagnostic Accuracy and Physiologic Assessment of Coronary Artery Disease With the Incorporation of Intermediate Stages of Exercise
J. Am. Coll. Cardiol.,
November 6, 2007;
50(19):
1857 - 1863.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
W. F. Armstrong and W. A. Zoghbi
Stress Echocardiography: Current Methodology and Clinical Applications
J. Am. Coll. Cardiol.,
June 7, 2005;
45(11):
1739 - 1747.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. D. Cheitlin, W. F. Armstrong, G. P. Aurigemma, G. A. Beller, F. Z. Bierman, J. L. Davis, P. S. Douglas, D. P. Faxon, L. D. Gillam, T. R. Kimball, et al.
ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article: a report of the American college of cardiology/American heart association task force on practice guidelines (ACC/AHA/ASE committee to update the 1997 guidelines for the clinical application of echocardiography)
J. Am. Coll. Cardiol.,
September 3, 2003;
42(5):
954 - 970.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. D. Cheitlin, W. F. Armstrong, G. P. Aurigemma, G. A. Beller, F. Z. Bierman, J. L. Davis, P. S. Douglas, D. P. Faxon, L. D. Gillam, T. R. Kimball, et al.
ACC/AHA/ASE 2003 Guideline Update for the Clinical Application of Echocardiography: Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography)
Circulation,
September 2, 2003;
108(9):
1146 - 1162.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Atar, T. Nagai, B. Cercek, T. Z. Naqvi, H. Luo, and R. J. Siegel
Pacing stress echocardiography: an alternative to pharmacologic stress testing
J. Am. Coll. Cardiol.,
November 15, 2000;
36(6):
1935 - 1941.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. Koch, R. M. Lang, M.-J. Garcia, L. Weinert, J. Bednarz, C. Korcarz, B. Coughlan, A. Spiegel, E. Kaji, K. T. Spencer, et al.
Objective evaluation of regional left ventricular wall motion during dobutamine stress echocardiographic studies using segmental analysis of color kinesis images
J. Am. Coll. Cardiol.,
August 1, 1999;
34(2):
409 - 419.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. J. Gibbons, K. Chatterjee, J. Daley, J. S. Douglas, S. D. Fihn, J. M. Gardin, M. A. Grunwald, D. Levy, B. W. Lytle, R. A. O'Rourke, et al.
ACC/AHA/ACP-ASIM guidelines for the management of patients with chronic stable angina: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Management of Patients With Chronic Stable Angina)
J. Am. Coll. Cardiol.,
June 1, 1999;
33(7):
2092 - 2197.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. D. Cheitlin, J. S. Alpert, W. F. Armstrong, G. P. Aurigemma, G. A. Beller, F. Z. Bierman, T. W. Davidson, J. L. Davis, P. S. Douglas, L. D. Gillam, et al.
ACC/AHA Guidelines for the Clinical Application of Echocardiography : A Report of the American College of Cardiology/ American Heart Association Task Force on Practice Guidelines (Committee on Clinical Application of Echocardiography) Developed in Collaboration With the American Society of Echocardiography
Circulation,
March 18, 1997;
95(6):
1686 - 1744.
[Full Text]
|
 |
|
|