cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1993; 21:458-464
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Allada, V
Right arrow Articles by Isabel-Jones, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Allada, V
Right arrow Articles by Isabel-Jones, J.

Selective anterograde coronary arteriography in neonates with d-transposition of the great arteries: accuracy and safety

V Allada, JM Jarmakani, RW Day, A Galindo, and JB Isabel-Jones

Department of Pediatrics, University of California, Los Angeles 90024.

OBJECTIVES. This study was designed to evaluate the accuracy and safety of selective anterograde coronary arteriography for the identification of the origin and branching pattern of the three main coronary arteries in neonates with d-transposition of the great arteries. BACKGROUND. Definition of coronary artery anatomy is important in neonates with d-transposition of the great arteries who are considered for the arterial switch operation. Balloon occlusion aortography defines coronary artery anatomy in most but not all cases. We have described a technique for selective anterograde coronary arteriography. METHODS. Between March 1987 and May 1991, 17 neonates underwent selective anterograde coronary arteriography and 29 patients had balloon occlusion aortography. After venous access was gained, a mesenteric catheter was used to engage the coronary ostia for contrast injection. All angiograms were reviewed by three independent observers and the coronary artery diagnoses were compared with operative findings. Complications with the catheterization procedure were also recorded. RESULTS. The accuracy of defining coronary artery anatomy with selective anterograde coronary arteriography (98 +/- 2%) was significantly (p < 0.05) greater than that achieved with balloon occlusion aortography (69 +/- 6%). There were no deaths with catheterization in either study group. Morbidity was similar in the groups with balloon occlusion aortography (7%) and selective anterograde coronary arteriography (6%) (p > 0.05) and was related to transient bradycardia induced by catheter manipulation in the right ventricle. No patient in either study group experienced cardiac ischemia. CONCLUSIONS. Selective anterograde coronary arteriography is an accurate and safe technique for the definition of coronary artery pattern in neonates with d-transposition of the great arteries.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
W. Tworetzky, D. B. McElhinney, M. M. Brook, V. Mohan Reddy, F. L. Hanley, and N. H. Silverman
Echocardiographic diagnosis alone for the complete repair of major congenital heart defects
J. Am. Coll. Cardiol., January 1, 1999; 33(1): 228 - 233.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. L. Myers
Transposition of the Great Arteries
Ann. Thorac. Surg., March 1, 1997; 63(3): 895 - 898.
[Full Text]



 
  cardiology careers collections past issues search home