cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1993; 21:26-34
© 1993 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haude, M
Right arrow Articles by Meyer, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haude, M
Right arrow Articles by Meyer, J

Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents

M Haude, R Erbel, H Issa, and J Meyer

2nd Medical Clinic, Johannes Gutenberg University, Mainz, Germany.

OBJECTIVES. The purpose of this study was to measure elastic recoil from sequential angiograms after balloon angioplasty and after implantation of a balloon-expandable Palmaz-Schatz stent in the same patient, and to compare the results with the late angiographic outcome. BACKGROUND. The immediate result of coronary balloon angioplasty is influenced by plastic deformation, primarily of the atherosclerotic plaque, and by elastic recoil, primarily of the less or nondiseased vessel circumference. METHODS. The extent of elastic recoil was measured quantitatively as the difference between maximal balloon size and the resulting vessel diameter or cross-sectional area. RESULTS. Analysis was performed in 60 patients who received a single stent for late restenosis after initially successful coronary balloon angioplasty. Minimal lumen diameter (minimal cross-sectional area) was 0.98 +/- 0.43 mm (0.97 +/- 0.67 mm2) before balloon angioplasty, 2.06 +/- 0.36 mm (3.68 +/- 1.17 mm2) after angioplasty (both p < 0.001 vs. values before angioplasty) and 2.98 +/- 0.26 mm (7.12 +/- 1.28 mm2) after stenting (both p < 0.001 vs. postangioplasty results). No significant changes in vessel reference diameters or areas were measured. Mean balloon/artery ratios were similar in both procedures, ranging from 0.93 to 0.96. The calculated mean elastic recoil was 0.98 +/- 0.50 mm in diameter (31%) and 3.67 +/- 2.05 mm2 in area (48%) after balloon angioplasty compared with 0.10 +/- 0.07 mm (3.5%) and 0.38 +/- 0.36 mm2 (5.1%) after stenting. Increasing balloon sizes induced increased vessel stretch, which was followed by increased elastic recoil in the angioplasty group in contrast to the stenting group. Short, noncalcified and eccentric lesions tend to be associated with increased recoil after balloon angioplasty. Overdilation or underdilation in one of the procedures, changes in postprocedural vasomotion or postprocedural thrombus formation was not responsible for this outcome. After 6 months mean minimal lumen diameter was 2.39 +/- 0.58 mm, suggesting a mean hyperplasia of 0.59 +/- 0.51 mm. Twelve patients (20%) had a follow-up diameter that was equal to or less than the mean postangioplasty result and eight patients (14%) had a diameter stenosis of > 50%. CONCLUSIONS. The implantation of a Palmaz-Schatz stent almost completely eliminates the decrease in vessel dimensions caused by elastic recoil and therefore diminishes the impact of hyperplasia and reduces the rate of restenosis.


This article has been cited by other articles:


Home page
Eur Heart JHome page
M. Ferenc, M. Gick, R.-P. Kienzle, H.-P. Bestehorn, K.-D. Werner, T. Comberg, P. Kuebler, H. J. Buttner, and F.-J. Neumann
Randomized trial on routine vs. provisional T-stenting in the treatment of de novo coronary bifurcation lesions
Eur. Heart J., December 1, 2008; 29(23): 2859 - 2867.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S. Aziz, J. L Morris, R. A Perry, and R. H Stables
Stent expansion: a combination of delivery balloon underexpansion and acute stent recoil reduces predicted stent diameter irrespective of reference vessel size
Heart, December 1, 2007; 93(12): 1562 - 1566.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
S. V. Dee and H. Samady
Evolving Strategies for the Prevention and Treatment of Coronary Restenosis
Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2003; 7(3): 281 - 293.
[Abstract] [PDF]


Home page
J Am Coll CardiolHome page
L. A. Garcia and J. P. Carrozza Jr
Stenting chroniccoronary artery occlusions: One step closer?
J. Am. Coll. Cardiol., May 7, 2003; 41(9): 1493 - 1495.
[Full Text] [PDF]


Home page
HeartHome page
G Finet, N J Weissman, G S Mintz, L F Satler, K M Kent, J R Laird, G A Adelmann, A E Ajani, M T Castagna, G Rioufol, et al.
Mechanism of lumen enlargement with direct stenting versus predilatation stenting: influence of remodelling and plaque characteristics assessed by volumetric intracoronary ultrasound
Heart, January 1, 2003; 89(1): 84 - 90.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
J. Rodes-Cabau, J. Candell-Riera, E. Domingo, J. Castell-Conesa, I. Anivarro, J. Angel, S. Aguade-Bruix, F. Padilla, A. Soto, and J. Soler-Soler
Frequency and Clinical Significance of Myocardial Ischemia Detected Early After Coronary Stent Implantation
J. Nucl. Med., December 1, 2001; 42(12): 1768 - 1772.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Haude, D. Baumgart, E. Verna, J. J. Piek, C. Vrints, P. Probst, and R. Erbel
Intracoronary Doppler- and Quantitative Coronary Angiography-Derived Predictors of Major Adverse Cardiac Events After Stent Implantation
Circulation, March 6, 2001; 103(9): 1212 - 1217.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C Schulz, R A Herrmann, C Beilharz, J Pasquantonio, and E Alt
Coronary stent symmetry and vascular injury determine experimental restenosis
Heart, April 1, 2000; 83(4): 462 - 467.
[Abstract] [Full Text]


Home page
CirculationHome page
M. J. Kern, S. Puri, R. G. Bach, T. J. Donohue, P. Dupouy, E. A. Caracciolo, W. R. Craig, F. Aguirre, E. Aptecar, T. L. Wolford, et al.
Abnormal Coronary Flow Velocity Reserve After Coronary Artery Stenting in Patients : Role of Relative Coronary Reserve to Assess Potential Mechanisms
Circulation, December 21, 1999; 100(25): 2491 - 2498.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. J. Wardeh, I. P. Kay, M. Sabate, V. L. M. A. Coen, A. L. Gijzel, J. M. R. Ligthart, A. den Boer, P. C. Levendag, W. J. van der Giessen, and P. W. Serruys
{beta}-Particle-Emitting Radioactive Stent Implantation : A Safety and Feasibility Study
Circulation, October 19, 1999; 100(16): 1684 - 1689.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
I. Kosa, R. Blasini, J. Schneider-Eicke, T. Dickfeld, F. J. Neumann, S. Ziegler, I. Matsunari, J. Neverve, A. Schomig, and M. Schwaiger
Early recovery of coronary flow reserve after stent implantation as assessed by positron emission tomography
J. Am. Coll. Cardiol., October 1, 1999; 34(4): 1036 - 1041.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. P. Carrozza Jr, S. E. Hosley, D. J. C. MD, and D. S. Baim
In Vivo Assessment of Stent Expansion and Recoil in Normal Porcine Coronary Arteries : Differential Outcome by Stent Design
Circulation, August 17, 1999; 100(7): 756 - 760.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
Y. Ueda, M. Kitakaze, M. Imakita, H. Ishibashi-Ueda, T. Minamino, H. Asanuma, T. Ozaki, E. Imamura, T. Kuzuya, and M. Hori
Glycoprotein IIb/IIIa Antagonist FK633 Could Not Prevent Neointimal Thickening in Stent Implantation Model of Canine Coronary Artery
Arterioscler. Thromb. Vasc. Biol., February 1, 1999; 19(2): 343 - 347.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Jeremias, S. Kutscher, M. Haude, D. Heinen, G. Holtmann, W. Senf, and R. Erbel
Nonischemic Chest Pain Induced by Coronary Interventions : A Prospective Study Comparing Coronary Angioplasty and Stent Implantation
Circulation, December 15, 1998; 98(24): 2656 - 2658.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
R. Erbel, M. Haude, H. W. Hopp, D. Franzen, H. J. Rupprecht, B. Heublein, K. Fischer, P. de Jaegere, P. Serruys, W. Rutsch, et al.
Coronary-Artery Stenting Compared with Balloon Angioplasty for Restenosis after Initial Balloon Angioplasty
N. Engl. J. Med., December 3, 1998; 339(23): 1672 - 1678.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. R. Holmes Jr., K. E. Kip, W. Yeh, S. F. Kelsey, K. M. Detre, D. O. Williams, and for the Investigators of the NHLBI PTCA Registry
Long-term analysis of conventional coronary balloon angioplasty and an initial "stent-like" result: The NHLBI PTCA registry
J. Am. Coll. Cardiol., September 1, 1998; 32(3): 590 - 595.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Bermejo, J. Botas, E. Garcia, J. Elizaga, J. Osende, J. Soriano, M. Abeytua, and J. L. Delcan
Mechanisms of Residual Lumen Stenosis After High-Pressure Stent Implantation : A Quantitative Coronary Angiography and Intravascular Ultrasound Study
Circulation, July 14, 1998; 98(2): 112 - 118.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Asakura, Y. Ueda, S. Nanto, A. Hirayama, T. Adachi, M. Kitakaze, M. Hori, and K. Kodama
Remodeling of In-Stent Neointima, Which Became Thinner and Transparent Over 3 Years : Serial Angiographic and Angioscopic Follow-up
Circulation, May 26, 1998; 97(20): 2003 - 2006.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Schmermund, D. Baumgart, G. Gorge, R. Seibel, D. Gronemeyer, J. Ge, M. Haude, J. Rumberger, and R. Erbel
Coronary Artery Calcium in Acute Coronary Syndromes : A Comparative Study of Electron-Beam Computed Tomography, Coronary Angiography, and Intracoronary Ultrasound in Survivors of Acute Myocardial Infarction and Unstable Angina
Circulation, September 2, 1997; 96(5): 1461 - 1469.
[Abstract] [Full Text]


Home page
CirculationHome page
M. Haude, G. Caspari, D. Baumgart, R. Brennecke, J. Meyer, and R. Erbel
Comparison of Myocardial Perfusion Reserve Before and After Coronary Balloon Predilatation and After Stent Implantation in Patients With Postangioplasty Restenosis
Circulation, August 1, 1996; 94(3): 286 - 297.
[Abstract] [Full Text]


Home page
CirculationHome page
H. Rud Andersen, M. Mæng, M. Thorwest, and E. Falk
Remodeling Rather Than Neointimal Formation Explains Luminal Narrowing After Deep Vessel Wall Injury : Insights From a Porcine Coronary (Re)stenosis Model
Circulation, May 1, 1996; 93(9): 1716 - 1724.
[Abstract] [Full Text]


Home page
CirculationHome page
R. Waksman, K. A. Robinson, I. R. Crocker, M. B. Gravanis, S. J. Palmer, C. Wang, G. D. Cipolla, and S. B. King III
Intracoronary Radiation Before Stent Implantation Inhibits Neointima Formation in Stented Porcine Coronary Arteries
Circulation, September 15, 1995; 92(6): 1383 - 1386.
[Abstract] [Full Text]


Home page
CirculationHome page
C. Hehrlein, C. Gollan, K. Donges, J. Metz, R. Riessen, P. Fehsenfeld, E. von Hodenberg, and W. Kubler
Low-Dose Radioactive Endovascular Stents Prevent Smooth Muscle Cell Proliferation and Neointimal Hyperplasia in Rabbits
Circulation, September 15, 1995; 92(6): 1570 - 1575.
[Abstract] [Full Text]


Home page
NEJMHome page
C. Landau, R. A. Lange, and L. D. Hillis
Percutaneous Transluminal Coronary Angioplasty
N. Engl. J. Med., April 7, 1994; 330(14): 981 - 993.
[Full Text]



 
  cardiology careers collections past issues search home