JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1992; 20:1417-1424
© 1992 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rovai, D
Right arrow Articles by L'Abbate, A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rovai, D
Right arrow Articles by L'Abbate, A

Myocardial washout of sonicated iopamidol reflects coronary blood flow in the absence of autoregulation

D Rovai, G Ghelardini, M Lombardi, MG Trivella, E Nevola, L Taddei, C Michelassi, A Distante, AN DeMaria, and A L'Abbate

CNR (Consiglio Nazionale Ricerche) Clinical Physiology Institute and University of Pisa, Italy.

OBJECTIVES. The aim of the study was to evaluate the relation between measurements derived from myocardial contrast echocardiography and coronary blood flow. BACKGROUND. Contrast echocardiography has the potential for measuring blood flow. METHODS. In six open chest anesthetized dogs, the left circumflex coronary artery was cannulated and perfused with blood drawn from the left femoral artery. While adenosine was infused into the circuit, circumflex flow was generated by a calibrated roller pump to the point of abolishing coronary autoregulation. At each of 25 levels of coronary blood flow, paired bolus injections of sonicated iopamidol were performed proximal to a mixing chamber. The perfused area of the left circumflex coronary artery was labeled by radioactive microspheres injected into the perfusion line. Two-dimensional echocardiographic images of the left ventricular short axis were digitized off-line, and myocardial videodensity was measured in the area perfused by the left circumflex coronary artery to generate time-intensity curves. RESULTS. The washout slope of curves showed a good correlation with coronary blood flow, ranging from 0.5 to 12.5 ml/min per g of tissue. This correlation was good both in individual dogs (correlation coefficient [r] ranging from 0.78 to 0.96) and in the group of animals as a whole (r = 0.85). Washout slope also showed a good correlation with coronary diastolic pressure (r = 0.80), which ranged from 23 to 114 mm Hg, suggesting a possible primary effect of pressure on contrast washout. However, coronary blood flow appeared to be a stronger predictor of washout slope (partial F = 26.5, p < 0.001) than did perfusion pressure (partial F = 5.9, p < 0.05 by multiple regression). The injection to injection variability in myocardial washout slope appeared to be high (24%). The gamma variate fitting of curves did not improve the correlation with coronary flow (r = 0.78). CONCLUSIONS. Myocardial washout of sonicated iopamidol reflects coronary blood flow in a model in which coronary autoregulation is abolished.


This article has been cited by other articles:


Home page
CirculationHome page
S. Ismail, A. R. Jayaweera, G. Camarano, L. W. Gimple, E. R. Powers, and S. Kaul
Relation Between Air-Filled Albumin Microbubble and Red Blood Cell Rheology in the Human Myocardium: Influence of Echocardiographic Systems and Chest Wall Attenuation
Circulation, August 1, 1996; 94(3): 445 - 451.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK