J Am Coll Cardiol, 1992; 20:1246-1250 © 1992 by the American College of Cardiology Foundation |
Department of Radiology, University of California Medical Center, San Francisco.
OBJECTIVES. The purpose of this study was to evaluate the ability of velocity-encoded nuclear magnetic resonance (NMR) imaging to quantify left to right intracardiac shunts in patients with an atrial septal defect. BACKGROUND. Quantification of intracardiac shunts is clinically important in planning therapy. METHODS. Velocity-encoded NMR imaging was used to quantify stroke flow in the aorta and in the main pulmonary artery in a group of patients who were known to have an increased pulmonary to systemic flow ratio (Qp/Qs). The velocity-encoded NMR flow data were used to calculate Qp/Qs, and these values were compared with measurements of Qp/Qs obtained with oximetric data derived from cardiac catheterization and from stroke volume measurements of the two ventricles by using volumetric data from biphasic spin echo and cine NMR images obtained at end-diastole and end-systole. RESULTS. Two independent observers measured Qp/Qs by using velocity-encoded NMR imaging in 11 patients and found Qp/Qs ranging from 1.4:1 to 3.9:1. These measurements correlated well with both oximetric data (r = 0.91, SEE = 0.35) and ventricular volumetric data (r = 0.94, SEE = 0.30). Interobserver reproducibility for Qp/Qs by velocity-encoded NMR imaging was good (r = 0.97, SEE = 0.20). CONCLUSIONS. Velocity-encoded NMR imaging is an accurate and reproducible method for measuring Qp/Qs in left to right shunts. Because it is completely noninvasive, it can be used to monitor shunt volume over time.
This article has been cited by other articles:
![]() |
L. E.J. Thomson, A. L. Crowley, J. F. Heitner, P. J. Cawley, J. W. Weinsaft, H. W. Kim, M. Parker, R. M. Judd, J. K. Harrison, and R. J. Kim Direct En Face Imaging of Secundum Atrial Septal Defects by Velocity-Encoded Cardiovascular Magnetic Resonance in Patients Evaluated for Possible Transcatheter Closure Circ Cardiovasc Imaging, July 1, 2008; 1(1): 31 - 40. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Schneider and J. W. Moore Patent Ductus Arteriosus Circulation, October 24, 2006; 114(17): 1873 - 1882. [Full Text] [PDF] |
||||
![]() |
K. I. Norton, C. Tong, R. B. J. Glass, and J. C. Nielsen Cardiac MR Imaging Assessment Following Tetralogy of Fallot Repair RadioGraphics, January 1, 2006; 26(1): 197 - 211. [Abstract] [Full Text] [PDF] |
||||
![]() |
Z. J. Wang, G. P. Reddy, M. B. Gotway, B. M. Yeh, and C. B. Higgins Cardiovascular Shunts: MR Imaging Evaluation RadioGraphics, October 1, 2003; 23(90001): S181 - 194. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. A. Varaprasathan, P. A. Araoz, C. B. Higgins, and G. P. Reddy Quantification of Flow Dynamics in Congenital Heart Disease: Applications of Velocity-encoded Cine MR Imaging RadioGraphics, July 1, 2002; 22(4): 895 - 905. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. W. Koskenvuo, J. J. Hartiala, J. Knuuti, H. Sakuma, J. O. Toikka, M. Komu, M. Saraste, and P. Niemi Assessing Coronary Sinus Blood Flow in Patients with Coronary Artery Disease: A Comparison of Phase-Contrast MR Imaging with Positron Emission Tomography Am. J. Roentgenol., November 1, 2001; 177(5): 1161 - 1166. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Beerbaum, H. Korperich, P. Barth, H. Esdorn, J. Gieseke, and H. Meyer Noninvasive Quantification of Left-to-Right Shunt in Pediatric Patients : Phase-Contrast Cine Magnetic Resonance Imaging Compared With Invasive Oximetry Circulation, May 22, 2001; 103(20): 2476 - 2482. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. K. Lund, M. F. Wendland, A. Shimakawa, H. Arheden, F. Ståhlberg, C. B. Higgins, and M. Saeed Coronary Sinus Flow Measurement by Means of Velocity-encoded Cine MR Imaging: Validation by Using Flow Probes in Dogs Radiology, November 1, 2000; 217(2): 487 - 493. [Abstract] [Full Text] |
||||
![]() |
D. Didier, O. Ratib, R. Lerch, and B. Friedli Detection and Quantification of Valvular Heart Disease with Dynamic Cardiac MR Imaging RadioGraphics, September 1, 2000; 20(5): 1279 - 1299. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Arheden, C. Holmqvist, U. Thilen, K. Hanséus, G. Björkhem, O. Pahlm, S. Laurin, and F. Ståhlberg Left-to-Right Cardiac Shunts: Comparison of Measurements Obtained with MR Velocity Mapping and with Radionuclide Angiography Radiology, May 1, 1999; 211(2): 453 - 458. [Abstract] [Full Text] |
||||
![]() |
N. Kawada, H. Sakuma, T. Yamakado, K. Takeda, N. Isaka, T. Nakano, and C. B. Higgins Hypertrophic Cardiomyopathy: MR Measurement of Coronary Blood Flow and Vasodilator Flow Reserve in Patients and Healthy Subjects Radiology, April 1, 1999; 211(1): 129 - 135. [Abstract] [Full Text] |
||||
![]() |
G. Holmvang, I. F. Palacios, G. J. Vlahakes, R. E. Dinsmore, S. W. Miller, R. R. Liberthson, P. C. Block, B. Ballen, T. J. Brady, and H. L. Kantor Imaging and Sizing of Atrial Septal Defects by Magnetic Resonance Circulation, December 15, 1995; 92(12): 3473 - 3480. [Abstract] [Full Text] |
||||
![]() |
W. G. Hundley, H. F. Li, R. A. Lange, D. P. Pfeifer, B. M. Meshack, J. E. Willard, C. Landau, D. Willett, L. D. Hillis, and R. M. Peshock Assessment of Left-to-Right Intracardiac Shunting by Velocity-Encoded, Phase-Difference Magnetic Resonance Imaging : A Comparison With Oximetric and Indicator Dilution Techniques Circulation, June 15, 1995; 91(12): 2955 - 2960. [Abstract] [Full Text] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |