JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1992; 20:1246-1250
© 1992 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brenner, L.
Right arrow Articles by Higgins, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brenner, L.
Right arrow Articles by Higgins, C.

Quantification of left to right atrial shunts with velocity-encoded cine nuclear magnetic resonance imaging

LD Brenner, GR Caputo, G Mostbeck, D Steiman, M Dulce, MD Cheitlin, M O'Sullivan, and CB Higgins

Department of Radiology, University of California Medical Center, San Francisco.

OBJECTIVES. The purpose of this study was to evaluate the ability of velocity-encoded nuclear magnetic resonance (NMR) imaging to quantify left to right intracardiac shunts in patients with an atrial septal defect. BACKGROUND. Quantification of intracardiac shunts is clinically important in planning therapy. METHODS. Velocity-encoded NMR imaging was used to quantify stroke flow in the aorta and in the main pulmonary artery in a group of patients who were known to have an increased pulmonary to systemic flow ratio (Qp/Qs). The velocity-encoded NMR flow data were used to calculate Qp/Qs, and these values were compared with measurements of Qp/Qs obtained with oximetric data derived from cardiac catheterization and from stroke volume measurements of the two ventricles by using volumetric data from biphasic spin echo and cine NMR images obtained at end-diastole and end-systole. RESULTS. Two independent observers measured Qp/Qs by using velocity-encoded NMR imaging in 11 patients and found Qp/Qs ranging from 1.4:1 to 3.9:1. These measurements correlated well with both oximetric data (r = 0.91, SEE = 0.35) and ventricular volumetric data (r = 0.94, SEE = 0.30). Interobserver reproducibility for Qp/Qs by velocity-encoded NMR imaging was good (r = 0.97, SEE = 0.20). CONCLUSIONS. Velocity-encoded NMR imaging is an accurate and reproducible method for measuring Qp/Qs in left to right shunts. Because it is completely noninvasive, it can be used to monitor shunt volume over time.


This article has been cited by other articles:


Home page
Circ Cardiovasc ImagingHome page
L. E.J. Thomson, A. L. Crowley, J. F. Heitner, P. J. Cawley, J. W. Weinsaft, H. W. Kim, M. Parker, R. M. Judd, J. K. Harrison, and R. J. Kim
Direct En Face Imaging of Secundum Atrial Septal Defects by Velocity-Encoded Cardiovascular Magnetic Resonance in Patients Evaluated for Possible Transcatheter Closure
Circ Cardiovasc Imaging, July 1, 2008; 1(1): 31 - 40.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. J. Schneider and J. W. Moore
Patent Ductus Arteriosus
Circulation, October 24, 2006; 114(17): 1873 - 1882.
[Full Text] [PDF]


Home page
RadioGraphicsHome page
K. I. Norton, C. Tong, R. B. J. Glass, and J. C. Nielsen
Cardiac MR Imaging Assessment Following Tetralogy of Fallot Repair
RadioGraphics, January 1, 2006; 26(1): 197 - 211.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
Z. J. Wang, G. P. Reddy, M. B. Gotway, B. M. Yeh, and C. B. Higgins
Cardiovascular Shunts: MR Imaging Evaluation
RadioGraphics, October 1, 2003; 23(90001): S181 - 194.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
G. A. Varaprasathan, P. A. Araoz, C. B. Higgins, and G. P. Reddy
Quantification of Flow Dynamics in Congenital Heart Disease: Applications of Velocity-encoded Cine MR Imaging
RadioGraphics, July 1, 2002; 22(4): 895 - 905.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. W. Koskenvuo, J. J. Hartiala, J. Knuuti, H. Sakuma, J. O. Toikka, M. Komu, M. Saraste, and P. Niemi
Assessing Coronary Sinus Blood Flow in Patients with Coronary Artery Disease: A Comparison of Phase-Contrast MR Imaging with Positron Emission Tomography
Am. J. Roentgenol., November 1, 2001; 177(5): 1161 - 1166.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. Beerbaum, H. Korperich, P. Barth, H. Esdorn, J. Gieseke, and H. Meyer
Noninvasive Quantification of Left-to-Right Shunt in Pediatric Patients : Phase-Contrast Cine Magnetic Resonance Imaging Compared With Invasive Oximetry
Circulation, May 22, 2001; 103(20): 2476 - 2482.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. K. Lund, M. F. Wendland, A. Shimakawa, H. Arheden, F. Ståhlberg, C. B. Higgins, and M. Saeed
Coronary Sinus Flow Measurement by Means of Velocity-encoded Cine MR Imaging: Validation by Using Flow Probes in Dogs
Radiology, November 1, 2000; 217(2): 487 - 493.
[Abstract] [Full Text]


Home page
RadioGraphicsHome page
D. Didier, O. Ratib, R. Lerch, and B. Friedli
Detection and Quantification of Valvular Heart Disease with Dynamic Cardiac MR Imaging
RadioGraphics, September 1, 2000; 20(5): 1279 - 1299.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
H. Arheden, C. Holmqvist, U. Thilen, K. Hanséus, G. Björkhem, O. Pahlm, S. Laurin, and F. Ståhlberg
Left-to-Right Cardiac Shunts: Comparison of Measurements Obtained with MR Velocity Mapping and with Radionuclide Angiography
Radiology, May 1, 1999; 211(2): 453 - 458.
[Abstract] [Full Text]


Home page
RadiologyHome page
N. Kawada, H. Sakuma, T. Yamakado, K. Takeda, N. Isaka, T. Nakano, and C. B. Higgins
Hypertrophic Cardiomyopathy: MR Measurement of Coronary Blood Flow and Vasodilator Flow Reserve in Patients and Healthy Subjects
Radiology, April 1, 1999; 211(1): 129 - 135.
[Abstract] [Full Text]


Home page
CirculationHome page
G. Holmvang, I. F. Palacios, G. J. Vlahakes, R. E. Dinsmore, S. W. Miller, R. R. Liberthson, P. C. Block, B. Ballen, T. J. Brady, and H. L. Kantor
Imaging and Sizing of Atrial Septal Defects by Magnetic Resonance
Circulation, December 15, 1995; 92(12): 3473 - 3480.
[Abstract] [Full Text]


Home page
CirculationHome page
W. G. Hundley, H. F. Li, R. A. Lange, D. P. Pfeifer, B. M. Meshack, J. E. Willard, C. Landau, D. Willett, L. D. Hillis, and R. M. Peshock
Assessment of Left-to-Right Intracardiac Shunting by Velocity-Encoded, Phase-Difference Magnetic Resonance Imaging : A Comparison With Oximetric and Indicator Dilution Techniques
Circulation, June 15, 1995; 91(12): 2955 - 2960.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1992 by the American College of Cardiology Foundation.