cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1992; 20:973-978
© 1992 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nakatani, S
Right arrow Articles by Miyatake, K
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nakatani, S
Right arrow Articles by Miyatake, K

Clinical application of transpulmonary contrast-enhanced Doppler technique in the assessment of severity of aortic stenosis

S Nakatani, T Imanishi, A Terasawa, S Beppu, S Nagata, and K Miyatake

Cardiology Division of Medicine, National Cardiovascular Center, Osaka, Japan.

OBJECTIVE. The aim of this study was to demonstrate the clinical usefulness of the transpulmonary contrast-enhanced Doppler technique by using it to assess the severity of aortic stenosis. BACKGROUND. Sonicated albumin microbubbles can pass through the pulmonary circulation after peripheral venous injection and have been reported to enhance Doppler signals from the left side of the heart. Therefore, their use to determine aortic flow velocity would facilitate the assessment of the severity of aortic stenosis. METHODS. Twenty-two patients with aortic stenosis and seven normal volunteers were examined. Aortic flow velocity was recorded with continuous wave Doppler technique from an apical window before and after injection of 2 ml of sonicated albumin. RESULTS. In 10 patients with aortic stenosis, the aortic velocity envelope was too indistinct to determine the peak velocity before sonicated albumin was injected. After injection, the aortic flow Doppler signal was enhanced in 9 of the 10 patients and the velocity envelope became clear enough to measure the peak velocity, enabling calculation of the transaortic pressure gradient. In the remaining 12 patients with aortic stenosis and in all 7 normal volunteers, the velocity envelope was clear before injection and became much clearer after injection. The calculated transaortic pressure gradient showed a good agreement with catheterization measurements (y = 1.1x-6.5, r = 0.88, p less than 0.001, SEE = 16 mm Hg, n = 13). Duration of Doppler signal enhancement was measured as the time during which the envelope was clearer than before injection throughout the ejection period. The duration was significantly shorter in patients with aortic stenosis than in normal volunteers (16 +/- 5 vs. 52 +/- 32 s, p less than 0.01). There was a significant correlation between left ventricular systolic pressure measured by catheterization and the duration of signal enhancement (r = -0.69), suggesting that albumin microbubbles were fragile at high pressure. CONCLUSIONS. The transpulmonary contrast-enhanced Doppler technique using sonicated albumin is useful for assessing the severity of aortic stenosis even in patients with poor Doppler recordings, although the duration of signal enhancement might be affected by left ventricular systolic pressure.


This article has been cited by other articles:


Home page
Eur J EchocardiogrHome page
G. Dwivedi, M. Hickman, and R. Senior
Accurate assessment of aortic stenosis with intravenous contrast
Eur J Echocardiogr, March 1, 2006; 7(2): 165 - 167.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
S. M. Bierig, J. V. Chapman, C. Newman, and V. Zuck
Contrast Echocardiography in Clinical Practice: Integration of Contrast Echocardiography
Journal of Diagnostic Medical Sonography, May 1, 2000; 16(3): 97 - 102.
[Abstract] [PDF]


Home page
CirculationHome page
M. D. Cheitlin, J. S. Alpert, W. F. Armstrong, G. P. Aurigemma, G. A. Beller, F. Z. Bierman, T. W. Davidson, J. L. Davis, P. S. Douglas, L. D. Gillam, et al.
ACC/AHA Guidelines for the Clinical Application of Echocardiography : A Report of the American College of Cardiology/ American Heart Association Task Force on Practice Guidelines (Committee on Clinical Application of Echocardiography) Developed in Collaboration With the American Society of Echocardiography
Circulation, March 18, 1997; 95(6): 1686 - 1744.
[Full Text]



 
  cardiology careers collections past issues search home