JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1992; 20:594-598
© 1992 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Muhlestein, J.
Right arrow Articles by Krucoff, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Muhlestein, J.
Right arrow Articles by Krucoff, M.

Prospective analysis of possible myocardial damage or hemolysis occurring as a result of prolonged autoperfusion angioplasty in humans

JB Muhlestein, PJ Quigley, EM Ohman, RP Bauman, MH Sketch Jr, JE Tcheng, CJ Davidson, RH Peter, VS Behar, MW Krucoff, et al.

Department of Medicine, Duke University Medical Center, Durham, North Carolina 27710.

OBJECTIVES. The purpose of this study was to further explore the procedural safety of prolonged (15-min) dilation using an autoperfusion coronary angioplasty balloon by assessing the degree of myocardial damage or hemolysis, if any, occurring as a result of the procedure. BACKGROUND. Prolonged balloon inflation periods may be beneficial during percutaneous transluminal coronary angioplasty. The duration of standard balloon angioplasty is often limited by the occurrence of myocardial ischemia due to loss of anterograde blood flow. Autoperfusion angioplasty allows continued myocardial perfusion during balloon inflation and has previously been shown to reduce but not totally eliminate acute myocardial ischemia during prolonged (up to 15 min) balloon inflation. The risk of intravascular hemolysis as a result of autoperfusion angioplasty has not yet been fully delineated. METHODS. Sixty-two consecutive patients (76% men; mean age 58 years) undergoing elective percutaneous transluminal coronary angioplasty of a single lesion were studied. Serial electrocardiographic and creatine kinase MB isoenzyme data were examined to detect evidence of myocardial damage. Tests for hemolysis (plasma free hemoglobin, serum haptoglobin and serum lactate dehydrogenase) were obtained in the 1st 24 consecutive patients. RESULTS. Inflation time was 14 +/- 4 min (mean +/- SD) and the procedure was successful (less than or equal to 50% residual lesion stenosis) in 59 patients (95%). Electrocardiographic evidence of myocardial infarction (greater than 1 mm persistent ST segment depression, greater than 1 mm ST segment elevation or new Q waves) was not observed in any patient. Cardiac enzyme assays were within the normal range in all patients. No evidence of hemolysis was found in the 24 consecutive patients studied. CONCLUSIONS. We conclude that prolonged autoperfusion angioplasty can be performed in patients without clinical evidence of myocardial damage or hemolysis.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Kollar, V. Kekesi, P. Soos, and A. Juhasz-Nagy
Left ventricular external subannular plication: an indirect off-pump mitral annuloplasty method in a canine model
J. Thorac. Cardiovasc. Surg., October 1, 2003; 126(4): 977 - 982.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Camenzind, P.-P. Kint, C. Di Mario, J. Ligthart, W. van der Giessen, E. Boersma, and P. W. Serruys
Intracoronary Heparin Delivery in Humans : Acute Feasibility and Long-term Results
Circulation, November 1, 1995; 92(9): 2463 - 2472.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1992 by the American College of Cardiology Foundation.