cardiology careers collections past issues search home
     

J Am Coll Cardiol, 1992; 20:210-217
© 1992 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Oeff, M
Right arrow Articles by Griffin, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Oeff, M
Right arrow Articles by Griffin, J.

Determination of patch electrode position for the internal cardioverter-defibrillator by cine computed tomography and its relation to the defibrillation threshold

M Oeff, JA Abbott, ED Scheinman, ES Yee, MM Scheinman, and JC Griffin

Department of Medicine, University of California, San Francisco.

Cardioverter-defibrillator implantation in 22 consecutive patients after aborted sudden cardiac death was followed by prospective determination of the correct anatomic position of epicardial patch electrodes by chest X-ray study and cine computed tomography; the data were compared with the defibrillation threshold obtained intraoperatively. Patch electrode position was qualitatively graded. Computed tomography improved the assessment as compared with X-ray study in 13 patients (59%), visualizing electrodes in relation to the underlying myocardial and vascular structures. Although the computed tomographic technique provided more precise visualization, its grading of patch position correlated as poorly as that of the X-ray study with the measured acute defibrillation threshold. Three-dimensional reconstruction by computed tomography made it possible to determine quantitatively left ventricular mass (free wall and septum) and the mass encompassed by the patch electrodes. The 34.6 +/- 13.7% (range 12.6 to 61.1%) of the left ventricular mass encompassed by both patch electrodes showed a linear relation to the defibrillation threshold (r = 0.64, p = 0.01). Differentiation of free wall and septal mass in these measurements revealed that the proportion of septal mass encompassed by patch electrodes correlated closely with the defibrillation threshold (r = -0.6, p = 0.019), whereas that of the free wall mass, although significantly larger (35.4 +/- 15.8 vs. 20.6 +/- 15.4 g, p = 0.007), did not. Thus, the position of epicardial patch electrodes could be reliably determined by computed tomography.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
S. Windecker, R. E. Ideker, V. J. Plumb, G. N. Kay, G. P. Walcott, and A. E. Epstein
The influence of ventricular fibrillation duration on defibrillation efficacy using biphasic waveforms in humans
J. Am. Coll. Cardiol., January 1, 1999; 33(1): 33 - 38.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
Y. Yamanouchi, K. A. Mowrey, M. J. Niebauer, P. J. Tchou, and B. L. Wilkoff
Additional Lead Improves Defibrillation Efficacy With an Abdominal `Hot Can' Electrode System
Circulation, December 16, 1997; 96(12): 4400 - 4407.
[Abstract] [Full Text]



 