Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1983; 2:597-606
© 1983 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Effron, M.
Right arrow Articles by Popp, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Effron, M.
Right arrow Articles by Popp, R.

Two-dimensional echocardiographic assessment of bioprosthetic valve dysfunction and infective endocarditis

MK Effron and RL Popp

Two-dimensional echocardiography of Hancock porcine heterograft valves was evaluated by correlation with clinical, hemodynamic, angiographic and pathologic findings in 80 patients. Ninety-five aortic and mitral bioprostheses were categorized by the type of valvular abnormality: group I, dysfunction due to primary tissue failure (41 valves); group II, dysfunction due to paravalvular leakage without infection (5 valves); group III, infective endocarditis with or without hemodynamic dysfunction (28 valves); and group IV, control cases without dysfunction or infection (21 valves). Increased size of a bioprosthetic leaflet image (minimal dimensions 3 x 5 mm) was observed in 46% (19 of 41) of cases with primary tissue failure and in 62% (10 of 16) of cases with leaflet vegetations due to endocarditis. Prolapse of leaflet echoes to below the level of the bioprosthetic sewing ring occurred in 76% (28 of 37) of cases with torn leaflets and also in 46% (6 of 13) of valves with vegetations on intact leaflets. Antegrade extension of leaflet echoes to beyond the level of the stents, observed in 4 of 16 cases with leaflet vegetations, was the only echocardiographic sign distinguishing leaflet infection from leaflet degeneration. Aortic bioprostheses with ring dehiscence affecting 40 to 90% of the anular circumference showed motion discordant with the motion of the adjacent aortic root and native anulus. Although echocardiographic abnormalities are frequently observed with bioprosthetic leaflet degeneration or infection, the echocardiographic appearance often does not distinguish between these two major complications and is best interpreted concurrently with other clinical and laboratory assessment.


This article has been cited by other articles:


Home page
HeartHome page
P. Pibarot and J. G. Dumesnil
Doppler echocardiographic evaluation of prosthetic valve function
Heart, January 1, 2012; 98(1): 69 - 78.
[Full Text] [PDF]


Home page
ANGIOLOGYHome page
A. M. Safi, T. Kwan, E. Afflu, A. Al Kamme, and L. Salciccioli
Paravalvular Regurgitation: A Rare Complication Following Valve Replacement Surgery
Angiology, June 1, 2000; 51(6): 479 - 487.
[Abstract] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement