JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1983; 2:497-505
© 1983 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wackers, F.
Right arrow Articles by Berger, H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Wackers, F.
Right arrow Articles by Berger, H.

Gold-195m for serial first pass radionuclide angiocardiography during upright exercise in patients with coronary artery disease

FJ Wackers, R Stein, L Pytlik, MW Plankey, R Lange, PB Hoffer, MJ Sands, BL Zaret, and HJ Berger

Sequential first pass radionuclide angiocardiography can be performed in rapid succession using gold-195m because of its low radiation dose and short half-life (30.5 seconds). In 25 patients with known or suspected coronary artery disease, first pass studies with gold-195m were obtained using a computerized multicrystal gamma camera at rest (n = 29), at the end of each 3 minute stage of exercise (n = 25) and immediately after exercise (n = 23). In 13 patients, assessment of left ventricular function during exercise with gold-195m was combined with thallium-201 stress scintigraphy. Left ventricular ejection fraction at rest assessed with technetium-99m and gold-195m correlated well (r = 0.93). In addition, repeat left ventricular ejection fractions at rest with gold-195m correlated closely (r = 0.96). Comparing peak exercise left ventricular ejection fraction with ejection fraction at rest, abnormal left ventricular reserve was found in 20 of 25 patients. Various abnormal patterns of left ventricular ejection fraction response were noted, showing the diagnostic potential of serial exercise angiocardiography. Thallium-201 myocardial images, obtained on a single crystal gamma camera after multiple gold-195m injections, were all of good diagnostic quality and were abnormal in 10 of 13 patients. Thus, multiple high count rate first pass studies can be obtained with gold-195m during and after exercise, allowing serial study of physiologic changes in left ventricular function during exercise. Thallium-201 myocardial imaging can be performed using the same exercise test, providing direct comparison of myocardial function and perfusion.





HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1983 by the American College of Cardiology Foundation.