Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1983; 2:77-84
© 1983 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ruschhaupt, D.
Right arrow Articles by Arcilla, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ruschhaupt, D.
Right arrow Articles by Arcilla, R.

Estimation of circumferential fiber shortening velocity by echocardiography

DG Ruschhaupt, PC Sodt, NA Hutcheon, and RA Arcilla

The M-mode and two-dimensional echocardiograms of 40 young patients were analyzed to compare the mean circumferential fiber shortening velocity (Vcf) of the left ventricle calculated separately by two methods. The mean circumferential fiber shortening velocity was derived from the M-mode echocardiogram as minor axis shortening/ejection time and derived from the two-dimensional echocardiogram as actual circumference change/ejection time. With computer assistance, circumference was determined from the short-axis two-dimensional echocardiographic images during end-diastole and end-systole. Good correlations were obtained between the left ventricular diameter derived by M-mode echocardiography and the vertical axis during end-diastole (r = 0.79) and end-systole (r = 0.88) derived by two-dimensional echocardiography. Likewise, high correlations were noted between diameter and circumference in end-diastole (r = 0.89) and end-systole (r = 0.88). However, comparison of Vcf obtained by M-mode echocardiography with that obtained by two-dimensional echocardiography showed only fair correlation (r = 0.68). Moreover, the diameter/circumference ratio determined in end-diastole and end-systole differed significantly (p less than 0.001), possibly owing to the change in geometry of the ventricular sector image during systole. Although Vcf derived by M-mode echocardiography is a useful index of left ventricular performance, it does not truly reflect the circumference change during systole.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
J.-M. Song, S. H. Kang, E.-J. Lee, M.-J. Shin, J. W. Lee, C. H. Chung, D.-H. Kim, D.-H. Kang, and J.-K. Song
Echocardiographic Predictors of Left Ventricular Function and Clinical Outcomes After Successful Mitral Valve Repair: Conventional Two-Dimensional Versus Speckle-Tracking Parameters
Ann. Thorac. Surg., June 1, 2011; 91(6): 1816 - 1823.
[Abstract] [Full Text] [PDF]


Home page
Postgrad. Med. J.Home page
I Moyssakis, R Tzanetea, P Tsaftaridis, I Rombos, D P Papadopoulos, V Kalotychou, and A Aessopos
Systolic and diastolic function in middle aged patients with sickle {beta} thalassaemia. An echocardiographic study
Postgrad. Med. J., November 1, 2005; 81(961): 711 - 714.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Takahashi, T. Anzai, T. Yoshikawa, Y. Maekawa, K. Mahara, M. Iwata, H. K. Hammond, and S. Ogawa
Angiotensin receptor blockade improves myocardial beta-adrenergic receptor signaling in postinfarction left ventricular remodeling: A possible link between beta-adrenergic receptor kinase-1 and protein kinase C epsilon isoform
J. Am. Coll. Cardiol., January 7, 2004; 43(1): 125 - 132.
[Abstract] [Full Text] [PDF]



 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement