JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1992; 19:1500-1507
© 1992 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Deutsch, H.
Right arrow Articles by Hilger, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Deutsch, H.
Right arrow Articles by Hilger, H.

Regurgitant flow in cardiac valve prostheses: diagnostic value of gradient echo nuclear magnetic resonance imaging in reference to transesophageal two-dimensional color Doppler echocardiography

HJ Deutsch, R Bachmann, U Sechtem, JM Curtius, M Jungehulsing, H Schicha, and HH Hilger

Klinik III fur Innere Medizin, University of Cologne, Germany.

Gradient echo nuclear magnetic resonance (NMR) imaging and transesophageal two-dimensional color Doppler echocardiography are flow-sensitive techniques that have been used in the diagnosis and grading of valvular regurgitation. To define the diagnostic value of gradient echo NMR imaging in the detection of regurgitant flow in cardiac valve prostheses and the differentiation of physiologic leakage flow from pathologic transvalvular or paravalvular leakage flow, 47 patients with 55 valve prostheses were examined. Color Doppler transesophageal echocardiography was used for comparison. Surgical confirmation of findings was obtained in 11 patients with 13 valve prostheses. Gradient echo NMR imaging showed regurgitant flow in 37 of 43 valves with a jet seen on transesophageal echocardiography and it detected physiologic leakage flow in 4 additional valves. There was 96% agreement between the two methods in distinguishing between physiologic and pathologic leakage flow. The methods differed on jet origin of pathologic leakage flow in six prostheses. The degree of regurgitation was graded by both NMR imaging and transesophageal echocardiography, according to the area of the regurgitant jet visualized; gradings were identical for 75% of valve prostheses. Quantification of jet length and area showed a good correlation between the two methods (r = 0.85 and r = 0.91, respectively). Gradient echo NMR imaging is a useful noninvasive technique for the detection, localization and estimation of regurgitant flow in cardiac valve prostheses. However, because transesophageal echocardiography is less time-consuming and less expensive, gradient echo NMR imaging is unlikely to displace transesophageal echocardiography and should be used only in the occasional patient who cannot be adequately imaged by echocardiography.


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
F. S. Pereles, V. Kapoor, J. C. Carr, O. P. Simonetti, E. A. Krupinski, V. Baskaran, and J. P. Finn
Usefulness of Segmented TrueFISP Cardiac Pulse Sequence in Evaluation of Congenital and Acquired Adult Cardiac Abnormalities
Am. J. Roentgenol., November 1, 2001; 177(5): 1155 - 1160.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
W. Vongpatanasin, L. D. Hillis, and R. A. Lange
Prosthetic Heart Valves
N. Engl. J. Med., August 8, 1996; 335(6): 407 - 416.
[Full Text] [PDF]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1992 by the American College of Cardiology Foundation.