JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1992; 19:1261-1270
© 1992 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dietz, W.
Right arrow Articles by Isner, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dietz, W.
Right arrow Articles by Isner, J.

Failure of angiography to accurately depict the extent of coronary artery narrowing in three fatal cases of percutaneous transluminal coronary angioplasty

WA Dietz, JM Tobis, and JM Isner

Department of Medicine (Cardiology), St. Elizabeth's Hospital, Tufts University School of Medicine, Boston, Massachusetts 02135.

The angiographic and pathologic findings are described in three patients who died less than 24 h after failed percutaneous transluminal coronary angioplasty. In two of the three patients, coronary angiography performed before angioplasty disclosed apparently focal lesions in the left anterior descending and right coronary arteries. In these two patients quantitative angiographic analysis disclosed a minimal lumen cross-sectional area of 1.82 and 0.47 mm2, respectively, at the sites of apparently focal stenoses before angioplasty; corresponding percent lumen area narrowing measured 84% and 91%, respectively, by quantitative angiography at these two sites. In the third patient, coronary angioplasty was undertaken when the patient developed spontaneous occlusion of the right coronary artery several hours after diagnostic angiography. Retrospective quantitative angiographic analysis of the right coronary artery revealed a minimal lumen cross-sectional area of 1.14 mm2, with 85% lumen area narrowing at the site of subsequent total occlusion and angioplasty. In each of these three patients, necropsy examination disclosed that the distribution of coronary narrowing in the artery treated by angioplasty was in fact not focal; rather, in each of these three patients, the artery treated by angioplasty, as well as the extramural coronary arteries not treated by angioplasty, were severely narrowed by diffusely distributed atherosclerotic plaque. The angiographic and necropsy findings in these three patients document that coronary narrowing that remains occult by virtue of diffuse distribution may complicate evaluation of patients being considered for coronary angioplasty.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
J. S. Choy and G. S. Kassab
Scaling of myocardial mass to flow and morphometry of coronary arteries
J Appl Physiol, May 1, 2008; 104(5): 1281 - 1286.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. R. Vale, D. W. Losordo, T. Tkebuchava, D. Chen, C. E. Milliken, and J. M. Isner
Catheter-based myocardial gene transfer utilizing nonfluoroscopic electromechanical left ventricular mapping
J. Am. Coll. Cardiol., July 1, 1999; 34(1): 246 - 254.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. C. Fishbein and R. J. Siegel
How Big Are Coronary Atherosclerotic Plaques That Rupture?
Circulation, November 15, 1996; 94(10): 2662 - 2666.
[Full Text]


Home page
CirculationHome page
J. Escaned, J. Baptista, C. Di Mario, J. Haase, Y. Ozaki, D. T. Linker, P. J. de Feyter, J. R.T.C. Roelandt, and P. W. Serruys
Significance of Automated Stenosis Detection During Quantitative Angiography: Insights Gained From Intracoronary Ultrasound Imaging
Circulation, September 1, 1996; 94(5): 966 - 972.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1992 by the American College of Cardiology Foundation.