Effect of external beam irradiation on neointimal hyperplasia after experimental coronary artery injury
RS Schwartz,
TM Koval,
WD Edwards,
AR Camrud,
KR Bailey,
K Browne,
RE Vlietstra,
and
DR Holmes Jr
Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota 55905.
Human coronary artery restenosis after percutaneous revascularization is a response to mechanical injury. Smooth muscle cell proliferation is a major component of restenosis, resulting in obstructive neointimal hyperplasia. Because ionizing radiation inhibits cellular proliferation, this study tested in a porcine coronary injury model the hypothesis that the hyperplastic response to coronary artery injury would be attenuated by X-irradiation. Deep arterial injury was produced in 37 porcine left anterior descending coronary artery segments with overexpanded, percutaneously delivered tantalum wire coils. Three groups of pigs were irradiated with 300-kV X-rays after coil injury: Group I (n = 10), 400 cGy at 1 day; Group II (n = 10), 400 cGy at 1 day and 400 cGy at 4 days and Group III (n = 9), 800 cGy at 1 day. Eight pigs in the control group underwent identical injury but received no radiation. Treatment efficacy was histologically assessed by measuring neointimal thickness and percent area stenosis. Mean neointimal thickness in all irradiated groups was significantly higher than in the control groups and thickness was proportional to X-ray dose. X-irradiation delivered at these doses and times did not inhibit proliferative neointima. Rather, it accentuated the neointimal response to acute arterial injury and may have potentiated that injury.
This article has been cited by other articles:

|
 |

|
 |
 
M. Desai, J. Mirzay-Razzaz, D. von Delft, S. Sarkar, G. Hamilton, and A. M. Seifalian
Inhibition of neointimal formation and hyperplasia in vein grafts by external stent/sheath
Vascular Medicine,
August 1, 2010;
15(4):
287 - 297.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
E. Therasse, D. Donath, J. Lesperance, J.-C. Tardif, M.-C. Guertin, V. L. Oliva, and G. Soulez
External Beam Radiation to Prevent Restenosis After Superficial Femoral Artery Balloon Angioplasty
Circulation,
June 21, 2005;
111(24):
3310 - 3315.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. S. Schwartz, N. A. Chronos, and R. Virmani
Preclinical restenosis models and drug-eluting stents: Still important, still much to learn
J. Am. Coll. Cardiol.,
October 6, 2004;
44(7):
1373 - 1385.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M.Y Salame, S Verheye, I.R Crocker, N.A.F Chronos, K.A Robinson, and S.B King III
Intracoronary radiation therapy
Eur. Heart J.,
April 2, 2001;
22(8):
629 - 647.
[PDF]
|
 |
|

|
 |

|
 |
 
K Kozuma, M.A Costa, M Sabate, C.J Slager, E Boersma, I.P Kay, J.P.A Marijnissen, S.G Carlier, J.J Wentzel, A Thury, et al.
Relationship between tensile stress and plaque growth after balloon angioplasty treated with and without intracoronary beta-brachytherapy
Eur. Heart J.,
December 2, 2000;
21(24):
2063 - 2070.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Kozuma, M. A. Costa, M. Sabate, I. P. Kay, J. P. A. Marijnissen, V. L. M. A. Coen, P. Serrano, J. M. R. Ligthart, P. C. Levendag, and P. W. Serruys
Three-Dimensional Intravascular Ultrasound Assessment of Noninjured Edges of {beta}-Irradiated Coronary Segments
Circulation,
September 26, 2000;
102(13):
1484 - 1489.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Hoher, J. Wohrle, M. Wohlfrom, H. Hanke, R. Voisard, H. H. Osterhues, M. Kochs, S. N. Reske, V. Hombach, and J. Kotzerke
Intracoronary {beta}-Irradiation With a Liquid 188Re-Filled Balloon : Six-Month Results From a Clinical Safety and Feasibility Study
Circulation,
May 23, 2000;
101(20):
2355 - 2360.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
C. Schulz, C. Niederer, C. Andres, R. A. Herrmann, X. Lin, R. Henkelmann, W. Panzer, C. Herrmann, D. F. Regulla, I. Wolf, et al.
Endovascular Irradiation From {beta}-Particle-Emitting Gold Stents Results in Increased Neointima Formation in a Porcine Restenosis Model
Circulation,
April 25, 2000;
101(16):
1970 - 1975.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. O. Trerotola, T. J. Carmody, R. D. Timmerman, K. A. Bergan, R. G. Dreesen, S. V. Frost, and M. Forney
Brachytherapy for the Prevention of Stenosis in a Canine Hemodialysis Graft Model: Preliminary Observations
Radiology,
September 1, 1999;
212(3):
748 - 754.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
C. Hehrlein, S. Kaiser, R. Riessen, J.u. Metz, P. Fritz, and W. Kubler
External beam radiation after stent implantation increases neointimal hyperplasia by augmenting smooth muscle cell proliferation and extracellular matrix accumulation
J. Am. Coll. Cardiol.,
August 1, 1999;
34(2):
561 - 566.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Heckenkamp and G. M. Lamuraglia
Intimal Hyperplasia, Arterial Remodeling, and Restenosis: An Overview
Perspectives in Vascular Surgery and Endovascular Therapy,
January 1, 1999;
11(2):
71 - 94.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Lafont and D. Faxon
Why do animal models of post-angioplasty restenosis sometimes poorly predict the outcome of clinical trials?
Cardiovasc Res,
July 1, 1998;
39(1):
50 - 59.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
V. Verin, P. Urban, Y. Popowski, M. Schwager, P. Nouet, P. A. Dorsaz, P. Chatelain, J. M. Kurtz, and W. Rutishauser
Feasibility of Intracoronary -Irradiation to Reduce Restenosis After Balloon Angioplasty: A Clinical Pilot Study
Circulation,
March 4, 1997;
95(5):
1138 - 1144.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
W. J. van der Giessen and P. W. Serruys
-Particle Emitting Stents Radiate Enthusiasm in the Search for Effective Prevention of Restenosis
Circulation,
November 15, 1996;
94(10):
2358 - 2360.
[Full Text]
|
 |
|

|
 |

|
 |
 
R. S. Schwartz, D. J. Holder, D. R. Holmes Jr, J. P. Veinot, A. R. Camrud, M. A. Jorgenson, and R. G. Johnson Jr
Neointimal Thickening After Severe Coronary Artery Injury Is Limited by Short-term Administration of a Factor Xa Inhibitor : Results in a Porcine Model
Circulation,
April 15, 1996;
93(8):
1542 - 1548.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
J. R. Laird, A. J. Carter, W. M. Kufs, T. G. Hoopes, A. Farb, S. H. Nott, R. E. Fischell, D. R. Fischell, R. Virmani, and T. A. Fischell
Inhibition of Neointimal Proliferation With Low-Dose Irradiation From a -Particle Emitting Stent
Circulation,
February 1, 1996;
93(3):
529 - 536.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
V. Verin, Y. Popowski, P. Urban, J. Belenger, M. Redard, M. Costa, M.-C. Widmer, M. Rouzaud, P. Nouet, E. Grob, et al.
Intra-arterial Beta Irradiation Prevents Neointimal Hyperplasia in a Hypercholesterolemic Rabbit Restenosis Model
Circulation,
October 15, 1995;
92(8):
2284 - 2290.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
C. Hehrlein, C. Gollan, K. Donges, J. Metz, R. Riessen, P. Fehsenfeld, E. von Hodenberg, and W. Kubler
Low-Dose Radioactive Endovascular Stents Prevent Smooth Muscle Cell Proliferation and Neointimal Hyperplasia in Rabbits
Circulation,
September 15, 1995;
92(6):
1570 - 1575.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
S. M. Schwartz, D. deBlois, and E. R. M. O'Brien
The Intima : Soil for Atherosclerosis and Restenosis
Circ. Res.,
September 1, 1995;
77(3):
445 - 465.
[Full Text]
|
 |
|

|
 |

|
 |
 
R. Waksman, K. A. Robinson, I. R. Crocker, M. B. Gravanis, G. D. Cipolla, and S. B. King III
Endovascular Low-Dose Irradiation Inhibits Neointima Formation After Coronary Artery Balloon Injury in Swine : A Possible Role for Radiation Therapy in Restenosis Prevention
Circulation,
March 1, 1995;
91(5):
1533 - 1539.
[Abstract]
[Full Text]
|
 |
|
|