Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1992; 19:657-662
© 1992 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by DiSciascio, G
Right arrow Articles by Douglas, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by DiSciascio, G
Right arrow Articles by Douglas, J., Jr

Reduction of ischemia with a new flow-adjustable hemoperfusion pump during coronary angioplasty. The Coronary Hemoperfusion Ischemia Prevention Study (CHIPS) Investigators

G DiSciascio, P Angelini, MG Vandormael, JA Brinker, MJ Cowley, LS Dean, and JS Douglas Jr

Department of Medicine, Medical College of Virginia, Richmond 23298.

A new flow-adjustable pump for coronary hemoperfusion to prevent ischemia during routine coronary angioplasty was evaluated in a multicenter prospective study of 110 patients. The protocol included patients who had angina or ST segment elevation during a control balloon inflation of less than or equal to 3 min. Hemoperfusion was performed by means of a new large lumen angioplasty catheter utilizing the patient's renal vein or femoral artery blood. Vessels perfused were the left anterior descending coronary artery (n = 74), right coronary artery (n = 39), left circumflex artery (n = 9) and coronary vein grafts (n = 15). Mean (+/- SD) perfusion flow was 41 +/- 9 ml/min (range 17 to 70); mean perfusion time was 9.3 +/- 4 min (median 8.5, range 2 to 30). Chest pain score (0 to 4) decreased from 2.9 +/- 1 to 1.4 +/- 1 during hemoperfusion (p less than 0.001); ST segment elevation score (0 to 4) decreased from 2.6 +/- 1 to 0.7 +/- 1 (p less than 0.005) and inflation time increased from 1.3 +/- 0.9 to 7 +/- 4 min, (p less than 0.001). At least a 50% increase in tolerated inflation time was obtained in 104 patients (95%). Free plasma hemoglobin and creatine kinase levels did not increase significantly over baseline values. Angioplasty was successful in 107 patients (97%), with mean stenosis reduced from 87 +/- 11% to 20 +/- 17%; 3 patients had urgent bypass surgery, 2 (1.8%) had a myocardial infarction (1 Q wave, 1 non-Q wave) and 2 (1.8%) died later in the hospital of probable noncoronary causes.(ABSTRACT TRUNCATED AT 250 WORDS)




 