J Am Coll Cardiol, 1992; 19:490-499 © 1992 by the American College of Cardiology Foundation |
Telectronics Pacing Systems, Denver, Colorado.
A second-generation implantable pacemaker-cardioverter-defibrillator was evaluated in 200 patients with sustained ventricular tachycardia, ventricular fibrillation or prior cardiac arrest. The device permits demand ventricular pacing for bradyarrhythmias and for long QT interval or tachycardia suppression, uses programmable (3 to 30 J) energy shocks for conversion of ventricular tachycardia and ventricular fibrillation and is used with conventional pacing and defibrillation leads. Ventricular tachycardia/fibrillation recognition is based on the ventricular electrogram rate and requires reconfirmation before shock delivery. Two hundred patients (mean age 62 years, mean left ventricular ejection fraction 36%) were enrolled and followed up for 0 to 23 months (mean 12). Epicardial lead system implantation was performed with use of an anterolateral thoracotomy (38%), median sternotomy (26%) and subxiphoid (20%) or subcostal (16%) approach. Perioperative mortality rate was 5.5% (all nonarrhythmic deaths). Implant defibrillation threshold ranged from 3 to 30 J (mean 15), with initial programmed shock energy ranging from 3 to 30 J (mean 22). Ventricular tachycardia/fibrillation sensing threshold ranged from 0.7 to 1.8 mV (median 1) and the tachycardia detection interval from 288 to 416 ms (median 320). Reprogramming of implant variables was necessary for reliable electrographic sensing (54 patients), programmed shock therapy (61 patients) and tachycardia detection rate (63 patients). Device activation for potential shock delivery occurred in 111 patients (55.5%) with actual shock delivery after ventricular tachycardia/fibrillation reconfirmation in 66 patients (33%). During follow-up study, there was a 1% arrhythmia mortality rate, 6.5% cardiac mortality rate and 10.5% total mortality rate. This study demonstrates that the programmable implantable pacemaker-cardioverter-defibrillator is effective in preventing arrhythmic death, yet reduces patient exposure to repeated shock therapy. Reprogramming is usually necessary during follow-up for optimal function.
This article has been cited by other articles:
![]() |
E. Occhetta, M. Bortnik, A. Magnani, G. Francalacci, and P. Marino Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias Europace, October 1, 2006; 8(10): 863 - 869. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. D. Sanders, M. A. Hlatky, and D. K. Owens Cost-Effectiveness of Implantable Cardioverter-Defibrillators N. Engl. J. Med., October 6, 2005; 353(14): 1471 - 1480. [Abstract] [Full Text] [PDF] |
||||
![]() |
Committee Members, G. Gregoratos, J. Abrams, A. E. Epstein, R. A. Freedman, D. L. Hayes, M. A. Hlatky, R. E. Kerber, G. V. Naccarelli, M. H. Schoenfeld, et al. ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices--Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines) J. Am. Coll. Cardiol., November 6, 2002; 40(9): 1703 - 1719. [Full Text] [PDF] |
||||
![]() |
G. Gregoratos, J. Abrams, A. E. Epstein, R. A. Freedman, D. L. Hayes, M. A. Hlatky, R. E. Kerber, G. V. Naccarelli, M. H. Schoenfeld, M. J. Silka, et al. ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Summary Article: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines) Circulation, October 15, 2002; 106(16): 2145 - 2161. [Full Text] [PDF] |
||||
![]() |
L. B. Mitchell, E. A. Pineda, J. L. Titus, P. M. Bartosch, and D. G. Benditt Sudden death in patients with implantable cardioverter defibrillators: The importance of post-shock electromechanical dissociation J. Am. Coll. Cardiol., April 17, 2002; 39(8): 1323 - 1328. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. D. Sanders, M. A. Hlatky, N. R. Every, K. M. McDonald, P. A. Heidenreich, L. S. Parsons, and D. K. Owens Potential Cost-Effectiveness of Prophylactic Use of the Implantable Cardioverter Defibrillator or Amiodarone after Myocardial Infarction Ann Intern Med, November 20, 2001; 135(10): 870 - 883. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Glatter and L. B. Liem Implantable Cardioverter Defibrillator: Current Progress and Management Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2000; 4(3): 162 - 179. [Abstract] [PDF] |
||||
![]() |
C.M Pratt, A.J Camm, J.T Bigger Jr, G Breithardt, R.W.F Campbell, A.E Epstein, L.J Kappenberger, K.-H Kuck, S Pocock, S Saksena, et al. Evaluation of antiarrhythmic drug efficacy in patients with an ICD. Unlimited potential or replete with complexity and problems? Eur. Heart J., November 1, 1999; 20(21): 1538 - 1552. [Abstract] [PDF] |
||||
![]() |
A. Schaumann, F. v. z. Muhlen, B. Herse, B.-D. Gonska, and H. Kreuzer Empirical Versus Tested Antitachycardia Pacing in Implantable Cardioverter Defibrillators : A Prospective Study Including 200 Patients Circulation, January 13, 1998; 97(1): 66 - 74. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Quan, J. H. Lee, O. Costantini, A. K. Konstantakos, H. K. Murrell, M. D. Carlson, J. A. Mackall, L. A. Biblo, and A. S. Geha Favorable Results of Implantable Cardioverter-Defibrillator Implantation in Patients Older Than 70 Years Ann. Thorac. Surg., December 1, 1997; 64(6): 1713 - 1717. [Abstract] [Full Text] |
||||
![]() |
G. Gioia, B. Bagheri, C. D. Gottlieb, D. S. Schwartzman, D. J. Callans, F. E. Marchlinski, J. Heo, and A. E. Iskandrian Prediction of Outcome of Patients With Life-Threatening Ventricular Arrhythmias Treated With Automatic Implantable Cardioverter-Defibrillators Using SPECT Perfusion Imaging Circulation, January 21, 1997; 95(2): 390 - 394. [Abstract] [Full Text] |
||||
![]() |
T. K. Kaul, A. K. Agnihotri, B. L. Fields, L. S. Riggins, D. A. Wyatt, and C. R. Jones CORONARY ARTERY BYPASS GRAFTING IN PATIENTS WITH AN EJECTION FRACTION OF TWENTY PERCENT OR LESS J. Thorac. Cardiovasc. Surg., May 1, 1996; 111(5): 1001 - 1012. [Abstract] [Full Text] |
||||
![]() |
J. A. Reiffel Data-driven Decisions: The Importance of Clinical Trials in Arrhythmia Management Journal of Cardiovascular Pharmacology and Therapeutics, January 1, 1996; 1(1): 79 - 88. [Abstract] [PDF] |
||||
![]() |
D. P. Zipes and D. Roberts Results of the International Study of the Implantable Pacemaker Cardioverter-Defibrillator : A Comparison of Epicardial and Endocardial Lead Systems Circulation, July 1, 1995; 92(1): 59 - 65. [Abstract] [Full Text] |
||||
![]() |
J. S. Lawton, K. A. Ellenbogen, M. A. Wood, B. S. Stambler, J. A. Spratt, A. S. Wechsler, and R. J. Damiano Jr Clinical Experience With Nonthoracotomy Cardioverter Defibrillators Ann. Thorac. Surg., May 1, 1995; 59(5): 1092 - 1098. [Abstract] [Full Text] |
||||
![]() |
J. M. Piehler, D. A. Killen, A. M. Borkon, W. A. Reed, M. E. Gorton, G. M. Gura Jr, and A. H. Kragel Right Atrial Compression Related to Defibrillator Patches Ann. Thorac. Surg., March 1, 1995; 59(3): 684 - 688. [Abstract] [Full Text] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |