JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1991; 18:1753-1758
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yeung-Lai-Wah, J.
Right arrow Articles by Kerr, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yeung-Lai-Wah, J.
Right arrow Articles by Kerr, C.

High success rate of atrioventricular node ablation with radiofrequency energy

JA Yeung-Lai-Wah, JF Alison, L Lonergan, R Mohama, R Leather, and CR Kerr

University Hospital, University of British Columbia, Department of Medicine, Vancouver, Canada.

Radiofrequency current was introduced as an alternative energy source for transcatheter ablation of cardiac arrhythmias to avoid the complications associated with direct current shocks. Initial use of radiofrequency current for complete ablation of the atrioventricular (AV) node yielded only moderate success rates, presumably because of the small size of electrodes and difficulty in localizing the AV node. The use of a larger 4-mm tip electrode for delivery of radiofrequency current and a method to better localize the AV node were prospectively studied in 32 patients undergoing catheter ablation of the AV node. There were 21 men and 11 women with a mean age of 62 +/- 12 years. Complete AV block was achieved immediately in 31 patients (97%) and it persisted in 28 patients (88%) during a mean follow-up period of 12 +/- 6 months. Three patients who had return of AV condition required no drug therapy for control of ventricular rate during atrial fibrillation. The number of radiofrequency pulses used to achieve complete AV block ranged from 1 to 5 (mean 1.9 +/- 1.1). In greater than 50% of the cases, only one radiofrequency pulse was required. The mean power and duration of radiofrequency pulses were 21.2 +/- 4.5 W and 33 +/- 15 s, respectively. All patients developed a stable junctional escape rhythm within 45 min of successful ablation. The QRS configuration was unchanged in 30 patients. One patient had a new right bundle branch block after ablation. There were no complications related to the ablation procedure.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Age AgeingHome page
I. G. Diab and M. J. Earley
Ablation of supraventricular tachycardia in a 96 year old
Age Ageing, May 1, 2007; 36(3): 346 - 348.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
K J Lipscomb, A M Zaidi, A P Fitzpatrick, and D LEFROY
Slow pathway modification for atrioventricular node re-entrant tachycardia: fast junctional tachycardia predicts adverse prognosis
Heart, January 1, 2001; 85(1): 44 - 47.
[Abstract] [Full Text]


Home page
J Am Coll CardiolHome page
E. S. Zado, D. J. Callans, C. D. Gottlieb, S. P. Kutalek, S. L. Wilbur, F. L. Samuels, S. E. Hessen, C. M. Movsowitz, J. M. Fontaine, S. E. Kimmel, et al.
Efficacy and safety of catheter ablation in octogenarians
J. Am. Coll. Cardiol., February 1, 2000; 35(2): 458 - 462.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
G A Ng, W Martin, and A C Rankin
Imaging of adenosine bolus transit following intravenous administration: insights into antiarrhythmic efficacy
Heart, August 1, 1999; 82(2): 163 - 169.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
C.-P. Lau, H.-F. Tse, and G. M. Ayers
Defibrillation-guided radiofrequency ablation of atrial fibrillation secondary to an atrial focus
J. Am. Coll. Cardiol., April 1, 1999; 33(5): 1217 - 1226.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
S. Levy
Atrioventricular junctional ablation and pacing for paroxysmal atrial fibrillation: the Barcelona recommendations
Europace, January 1, 1999; 1(1): 2 - 4.
[PDF]


Home page
EuropaceHome page
M. Brignole, M. Gammage, L. Jordaens, R. Sutton, and on behalf of the Barcelona Discussion Group
Report of a study group on ablate and pace therapy for paroxysmal atrial fibrillation
Europace, January 1, 1999; 1(1): 8 - 13.
[Abstract] [PDF]


Home page
HeartHome page
M BRIGNOLE
Ablate and pace: a pragmatic approach to paroxysmal atrial fibrillation not controlled by antiarrhythmic drugs
Heart, June 1, 1998; 79(6): 531 - 533.
[Full Text]


Home page
HeartHome page
H J Marshall, Z I Harris, M J Griffith, and M D Gammage
Atrioventricular nodal ablation and implantation of mode switching dual chamber pacemakers: effective treatment for drug refractory paroxysmal atrial fibrillation
Heart, June 1, 1998; 79(6): 543 - 547.
[Abstract] [Full Text]


Home page
CirculationHome page
A. D. Krahn, G. J. Klein, R. Yee, M. N. Basta, and J. K. Lee
Progressive Anterior Ablation in the Coronary Sinus Region : Evidence to Support the Presence of a `Slow Pathway' Input in Normal Patients?
Circulation, November 18, 1997; 96(10): 3477 - 3483.
[Abstract] [Full Text]


Home page
ANGIOLOGYHome page
S. G. Kim, V. Sompalli, A. Rameneni, M. K. Gadde, M. Pamidi, R. Pathapati, K. J. Ferrick, J. Gross, U. Ben-Zur, S. Furman, et al.
Symptomatic Improvement After AV Nodal Ablation and Pacemaker Implantation for Refractory Atrial Fibrillation and Atrial Flutter
Angiology, November 1, 1997; 48(11): 933 - 938.
[Abstract] [PDF]


Home page
CirculationHome page
S.-A. Chen, S.-H. Lee, C.-E. Chiang, C.-T. Tai, T.-J. Wu, C.-C. Cheng, Z.-C. Wen, C.-W. Chiou, K.-C. Ueng, and M.-S. Chang
Electrophysiological Mechanisms in Successful Radiofrequency Catheter Modification of Atrioventricular Junction for Patients With Medically Refractory Paroxysmal Atrial Fibrillation
Circulation, May 1, 1996; 93(9): 1690 - 1701.
[Abstract] [Full Text]


Home page
CirculationHome page
S. Nath, J. P. DiMarco, J. P. Mounsey, J. H. Lobban, and D. E. Haines
Correlation of Temperature and Pathophysiological Effect During Radiofrequency Catheter Ablation of the AV Junction
Circulation, September 1, 1995; 92(5): 1188 - 1192.
[Abstract] [Full Text]


Home page
CirculationHome page
J. F. Alison, J. A. Yeung-Lai-Wah, M. Schulzer, and C. R. Kerr
Characterization of Junctional Rhythm After Atrioventricular Node Ablation
Circulation, January 1, 1995; 91(1): 84 - 90.
[Abstract] [Full Text]


Home page
NEJMHome page
B. D. Williamson, K. C. Man, E. Daoud, M. Niebauer, S. A. Strickberger, and F. Morady
Radiofrequency Catheter Modification of Atrioventricular Conduction to Control the Ventricular Rate during Atrial Fibrillation
N. Engl. J. Med., October 6, 1994; 331(14): 910 - 917.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1991 by the American College of Cardiology Foundation.