J Am Coll Cardiol, 1991; 18:1493-1498 © 1991 by the American College of Cardiology Foundation |
Noninvasive Cardiac Laboratory, Massachusetts General Hospital, Harvard Medical School, Boston.
The magnitude and spatial distribution of normal leakage through mechanical prosthetic valves were studied in an in vitro model of mitral regurgitation. The effective regurgitant orifice was calculated from regurgitant rate at different transvalvular pressure differences and flow velocities. This effective orifice area was 0.6 to 2 mm2 for three tilting disc prostheses (Medtronic-Hall sizes 21, 25 and 29) and 0.2 to 1.1 mm2 for three bileaflet valves (St. Jude Medical sizes 21, 25 and 33). In the single disc valves, Doppler color flow examination disclosed a prominent central regurgitant jet around the central hole for the strut, accompanied by minor leakage along the rim of the disc (central to peripheral jet area ratio 3.3 +/- 1.2). The bileaflet prostheses showed a peculiar complex pattern: in planes parallel to the two disc axes, convergent peripherally arising jets were visualized, whereas in orthogonal planes several diverging jets were seen. Mounting the disc and bileaflet valves on a water-filled tube allowed reproduction and interpretation of this pattern: for the bileaflet valve, the jets originated predominantly from valve ring protrusions that contained the axis hinge points and created a converging V pattern in planes parallel to the leaflets and a diverging V pattern in orthogonal planes. Similar patterns were observed during transesophageal echocardiography in 20 patients with a normally functioning St. Jude prosthesis. In 10 patients with a Medtronic-Hall valve, a dominant central jet was observed with one or more smaller peripheral jets. The median central to peripheral jet area ratio was 5 to 1.(ABSTRACT TRUNCATED AT 250 WORDS)
This article has been cited by other articles:
![]() |
M. Enriquez-Sarano, V. T. Nkomo, and H. Michelena Principles and Practice of Echocardiography in Cardiac Surgery Card. Surg. Adult, January 1, 2008; 3(2008): 315 - 348. [Full Text] |
||||
![]() |
V. G. Davila-Roman, A. D. Waggoner, E. D. Kennard, R. Holubkov, W. R. E. Jamieson, L. Englberger, T. P. Carrel, and H. V. Schaff Prevalence and severity of paravalvular regurgitation in the Artificial Valve Endocarditis Reduction Trial (AVERT) echocardiography study J. Am. Coll. Cardiol., October 6, 2004; 44(7): 1467 - 1472. [Abstract] [Full Text] [PDF] |
||||
![]() |
P S Rahko Assessing prosthetic mitral valve regurgitation by transoesophageal echo/Doppler Heart, May 1, 2004; 90(5): 476 - 478. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Firstenberg, A. J. Morehead, J. D. Thomas, N. G. Smedira, D. M. Cosgrove III, and M. A. Marchand Short-term hemodynamic performance of the mitral Carpentier-Edwards PERIMOUNT pericardial valve Ann. Thorac. Surg., May 1, 2001; 71 (2007): S285 - S288. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Morehead, M. S. Firstenberg, T. Shiota, J. Qin, G. Armstrong, D. M. Cosgrove III, and J. D. Thomas Intraoperative echocardiographic detection of regurgitant jets after valve replacement Ann. Thorac. Surg., January 1, 2000; 69(1): 135 - 139. [Abstract] [Full Text] [PDF] |
||||
| HOME | SUBSCRIPTIONS | CURRENT ISSUE | PAST ISSUES | CARDIOSOURCE | SEARCH | HELP | FEEDBACK |