JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1991; 18:1303-1308
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Benson, L.
Right arrow Articles by Freedom, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Benson, L.
Right arrow Articles by Freedom, R.

Percutaneous implantation of a balloon-expandable endoprosthesis for pulmonary artery stenosis: an experimental study

LN Benson, F Hamilton, H Dasmahapatra, M Rabinowitch, JC Coles, and RM Freedom

Department of Paediatrics, Hospital for Sick Children, Toronto, Ontario, Canada.

Conventional therapy to treat peripheral pulmonary artery stenosis (surgery or balloon angioplasty) has been frustrating. Recently a variety of peripheral vascular stenoses, in which conventional approaches are disappointing, have become amenable to therapy with the use of a balloon-expandable endovascular stent. This experimental study was designed to assess the application of such a prosthesis in artificially created pulmonary artery stenoses. In 9 of 12 2-week old pigs, left pulmonary artery stenosis was surgically created (3.9 +/- 1.1 mm diameter and 7 +/- 1 mm Hg mean gradient). At 6.8 +/- 1 weeks of age (13 +/- 4 kg), percutaneous (femoral venous) implantation of a 3-cm long balloon-expandable (maximal diameter 18 mm) stent (three placed into normal pulmonary artery branches) using a 3-cm x 10-mm balloon dilating catheter was achieved without technical difficulties. Stenoses were enlarged to 8.3 +/- 1.4 mm with a decrease in mean gradient to 1 +/- 1 mm Hg that was maintained through 3.5 months of follow-up. Histologic and electron micrographic studies identified normal-appearing neoendothelial layering over stent struts without intraluminal or peripheral thrombus formation and nonobstructed side branching to lung subsegments. These findings support the application of this approach in the treatment of pulmonary stenosis that is not amenable to conventional therapy.


This article has been cited by other articles:


Home page
HeartHome page
M Peuster, P Wohlsein, M Brugmann, M Ehlerding, K Seidler, C Fink, H Brauer, A Fischer, and G Hausdorf
A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal---results 6-18 months after implantation into New Zealand white rabbits
Heart, November 1, 2001; 86(5): 563 - 569.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
H. D. Allen, R. H. Beekman III, A. Garson Jr, Z. M. Hijazi, C. Mullins, M. P. O'Laughlin, and K. A. Taubert
Pediatric Therapeutic Cardiac Catheterization : A Statement for Healthcare Professionals From the Council on Cardiovascular Disease in the Young, American Heart Association
Circulation, February 17, 1998; 97(6): 609 - 625.
[Full Text] [PDF]


Home page
CirculationHome page
R. Fogelman, D. Nykanen, J. F. Smallhorn, B. W. McCrindle, R. M. Freedom, and L. N. Benson
Endovascular Stents in the Pulmonary Circulation : Clinical Impact on Management and Medium-term Follow-up
Circulation, August 15, 1995; 92(4): 881 - 885.
[Abstract] [Full Text]




HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1991 by the American College of Cardiology Foundation.