Transcatheter closure of a large patent ductus arteriosus with the clamshell septal umbrella
ND Bridges,
SB Perry,
I Parness,
JF Keane,
and
JE Lock
Department of Cardiology, Children's Hospital, Boston, Massachusetts 02131.
In 14 patients undergoing transcatheter closure of a large (greater than 4 mm diameter) patent ductus arteriosus, occlusion was attempted with use of the Bard Clamshell septal umbrella. Patient age ranged from 0.7 to 30.4 years. Isolated patent ductus arteriosus was present in 11 patients; 3 had additional congenital heart lesions. Moderate or severe pulmonary hypertension was present in four patients. The diameter of the patent ductus arteriosus ranged from 4.5 to 14 mm, as determined by contrast injection through an 11F sheath or by balloon sizing; it appeared larger by this method than by the standard angiographic method. All 14 patent ductus arteriosi were successfully closed. Prior embolization of a Rashkind umbrella was the reason for using a Clamshell device in three patients; one additional embolization of a Clamshell device occurred. All errant devices were retrieved at cardiac catheterization, without associated hemodynamic instability. No other complications occurred. Among the 14 patients, 11 had complete ductal closure by Doppler color flow mapping at last follow-up and 3 had trivial residual flow. All four patients having associated complex lesions or pulmonary hypertension, or both, had symptomatic improvement after the procedure, although one child (with Shone's anomaly) died 3 months later. The Clamshell device provides stable and effective closure of a large patent ductus arteriosus, and allows transcatheter closure to be offered to some patients who were previously considered unsuitable for this procedure.
This article has been cited by other articles:

|
 |

|
 |
 
C. Spies, Q.-L. Cao, and Z. M. Hijazi
Transcatheter closure of congenital and acquired septal defects
Eur. Heart J. Suppl.,
September 1, 2010;
12(suppl_E):
E24 - E34.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Laks, D. Marelli, M. Plunkett, and J. Myers
Adult Congenital Heart Disease
Card. Surg. Adult,
January 1, 2008;
3(2008):
1431 - 1464.
[Full Text]
|
 |
|

|
 |

|
 |
 
R. H. Pass, Z. Hijazi, D. T. Hsu, V. Lewis, and W. E. Hellenbrand
Multicenter USA amplatzer patent ductus arteriosus occlusion device trial: Initial and one-year results
J. Am. Coll. Cardiol.,
August 4, 2004;
44(3):
513 - 519.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Laks, D. Marelli, M. Plunkett, J. Odim, and J. Myers
Adult Congenital Heart Disease
Card. Surg. Adult,
January 1, 2003;
2(2003):
1329 - 1358.
[Full Text]
|
 |
|

|
 |

|
 |
 
M. U. Braun, D. Fassbender, S. P. Schoen, M. Haass, R. Schraeder, W. Scholtz, and R. H. Strasser
Transcatheter closure of patent foramen ovale in patients with cerebral ischemia
J. Am. Coll. Cardiol.,
June 19, 2002;
39(12):
2019 - 2025.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. A. Bilkis, M. Alwi, S. Hasri, A. L. Haifa, K. Geetha, M. A. Rehman, and I. Hasanah
The Amplatzer duct occluder: experience in 209 patients
J. Am. Coll. Cardiol.,
January 1, 2001;
37(1):
258 - 261.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Sreenivas Kumar, A. Kapoor, N. Sinha, M. Shahi, P. K. Goel, S. Radhakrishnan, and S. Srivastava
Percutaneous Occlusion of Patent Ductus Arteriosus with Controlled-Release Coil
Asian Cardiovasc Thorac Ann,
September 1, 1999;
7(3):
204 - 208.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
F. Shamsham, T. Kwan, A. M. Safi, and L. T. Clark
Successful Transcatheter Closure of a Patent Ductus Arteriosus: Using Two Gianturco Coils in a 41-Year-Old Woman: A Case Report
Angiology,
June 1, 1999;
50(6):
519 - 522.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
P. S. Rao, S. H. Kim, J.-Y. Choi, C. Rey, J. Haddad, F. Marcon, K. Walsh, and E. B. Sideris
Follow-up results of transvenous occlusion of patent ductus arteriosus with the buttoned device
J. Am. Coll. Cardiol.,
March 1, 1999;
33(3):
820 - 826.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
O. Galal, R. Nehgme, F. Al-Fadley, M. d. Moor, F. I. Abbag, S. H. Al-Oufi, E. Williams, M. E. Fawzy, and Z. Al-Halees
The Role of Surgical Ligation of Patent Ductus Arteriosus in the Era of the Rashkind Device
Ann. Thorac. Surg.,
February 1, 1997;
63(2):
434 - 437.
[Abstract]
[Full Text]
|
 |
|

|
 |

|
 |
 
M. A. Kuhn, L. A. Latson, J. P. Cheatham, B. McManus, J. M. Anderson, K. L. Kilzer, and J. Furst
Biological Response to Bard Clamshell Septal Occluders in the Canine Heart
Circulation,
April 1, 1996;
93(7):
1459 - 1463.
[Abstract]
[Full Text]
|
 |
|
|