Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1991; 18:1280-1284
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohen, T.
Right arrow Articles by Griffin, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohen, T.
Right arrow Articles by Griffin, J.

Emergency intracardiac defibrillation for refractory ventricular fibrillation during routine electrophysiologic study

TJ Cohen, MM Scheinman, BT Pullen, NA Chiesa, R Gonzalez, JM Herre, and JC Griffin

Department of Medicine, University of California, San Francisco 94143.

Ventricular fibrillation refractory to cardiopulmonary resuscitation including multiple transthoracic defibrillations occurred in four patients during 1,215 consecutive ventricular tachycardia induction studies. A technique of emergency intracardiac defibrillation for management of refractory ventricular fibrillation is described. In four patients, stable monomorphic ventricular tachycardia (320 to 570 ms cycle length) was induced during the study and overdrive ventricular pacing resulted in ventricular fibrillation. These patients did not respond to prompt transthoracic defibrillations (5 to 15 attempts/patient) and cardiopulmonary resuscitation, including antiarrhythmic therapy. As a last resort, intracardiac defibrillation was performed with use of a previously inserted standard right ventricular quadripolar catheter as cathode and a posterior skin patch as anode. High energy intracardiac defibrillation pulses (100 to 500 J) delivered from a standard defibrillator successfully terminated each arrhythmia. Intracardiac defibrillation is technically simple and appears effective in terminating refractory ventricular fibrillation in the electrophysiology laboratory. However, further research is necessary to determine the safety and efficacy of this technique, as well as potential applications in other emergency settings.




 
  CME Topic Collections Past Issues Search Current Issue Home

Advertisement