JACC
HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
 QUICK SEARCH:   [advanced]


     


J Am Coll Cardiol, 1991; 18:1034-1042
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gerstenfeld, E.
Right arrow Articles by Swiryn, S
Right arrow Search for Related Content
PubMed
Right arrow Articles by Gerstenfeld, E.
Right arrow Articles by Swiryn, S

Detection of changes in atrial endocardial activation with use of an orthogonal catheter

EP Gerstenfeld, AV Sahakian, JM Baerman, KM Ropella, and S Swiryn

Department of Biomedical Engineering, Northwestern University, Evanston, Illinois.

The ability of a catheter with an orthogonal electrode configuration to sense differences in the direction of local atrial endocardial activation was tested in 18 consecutive patients with intact retrograde conduction. In all 18, discrimination of anterograde from retrograde conduction at a single atrial site was examined; in 5 of the 18, multiple sites were examined to determine if the discriminatory ability of the catheter was site dependent. The catheter was specially designed with bipoles in the x, y and z directions. A vector was computed for each electrogram during anterograde and retrograde conduction. Electrogram amplitude along the standard bipole was also compared for anterograde and retrograde conduction. Mean electrogram amplitude for the standard bipole was significantly different for anterograde than for retrograde conduction in 17 of 18 patients (mean +/- SD 4 +/- 1.9 vs. 2.7 +/- 1.3 mV; p less than 0.005), with complete separation of amplitude distributions in 4 patients. The electrogram vector during anterograde conduction was significantly different from that during retrograde conduction in all 18 patients (p less than 0.0001), with complete separation of vector distributions in 14. In some patients with multiple site recordings, the choice of site greatly affected separation based on electrogram amplitude or vector, or both. The orthogonal catheter can be used to sense directional differences in local endocardial activation. The catheter shows promise for discriminating anterograde from retrograde conduction and examining the direction of endocardial activation in the heart during an electrophysiologic examination.





HOME SUBSCRIPTIONS CURRENT ISSUE PAST ISSUES CARDIOSOURCE SEARCH HELP FEEDBACK
Copyright © 1991 by the American College of Cardiology Foundation.