Advertisement

Click here for more guidelines.

 
 




CME Topic Collections Past Issues Search Current Issue Home
     

J Am Coll Cardiol, 1991; 18:587-595
© 1991 by the American College of Cardiology Foundation
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yeh, S.
Right arrow Articles by Wu, D
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yeh, S.
Right arrow Articles by Wu, D

Repetitive sinoatrial exit block as the major mechanism of drug-provoked long sinus or atrial pause

SJ Yeh, T Yamamoto, FC Lin, CC Wang, and D Wu

Department of Medicine, Chang Gung Medical College, Taipei, Taiwan.

Prolonged sinus or atrial pause occurred in six patients with paroxysmal supraventricular tachycardia after drug administration. All six patients had normal sinus node function during control electrophysiologic study; the sinus cycle length ranged from 510 to 900 ms (mean 743 +/- 141) and the longest sinus node recovery time ranged from 800 to 1,230 ms (mean 1,018 +/- 168). A long sinus or atrial pause occurring at the termination of tachycardia or cessation of atrial pacing, ranging from 3,100 to 8,200 ms (mean 6,270 +/- 1,674), was provoked by the administration of various drugs. These included an intravenous bolus injection of adenosine triphosphate (5 mg; one patient), intravenous bolus injection of verapamil (5 mg; one patient), a combination of a single oral dose of diltiazem (120 mg) and propranolol (20 to 40 mg; three patients), oral diltiazem (240 mg/day; one patient) and a combination of oral diltiazem (240 mg/day) and propranolol (160 mg/day; one patient). In five patients, low frequency deflections suggestive of sinus node activity with a cycle length between 620 and 3,500 ms were recorded during pauses. These findings suggest that repetitive sinoatrial exit block was responsible for the pause. Sinus slowing with a long arrest suggesting suppression of sinus automaticity was also noted in three of these five patients; the longest sinus arrest in these three patients was 4,160, 4,800 and greater than 4,910 ms, respectively. The remaining patient with a pause of 6,840 ms had no recordable sinus activity, either reflecting suppression of sinus automaticity or technical failure.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Postgrad. Med. J.Home page
B Medarov, S Tongia, and L Rossoff
Sinoatrial block complicating legionnaire's disease
Postgrad. Med. J., November 1, 2003; 79(937): 657 - 659.
[Abstract] [Full Text] [PDF]



 